Simtronics GD10P Infrared Point Gas Detector

Code: GD10P
  • Gases Flammable or CO2
  • Fast response T90 < 1.5 seconds
  • Approvals: ATEX, CSA, IECEx & INMETRO

In StockMake An Enquiry

An infrared point continuous gas detector using a silicon-based solid-state source, the Simtronics GD10P, can monitor Hydrocarbons or Carbon Dioxide gas. Suitable for Marine, Petrochemical, offshore and general industry applications. The PE version detects flammable gas in large volumes of air.

True dual-path double compensation optical design means no calibration is necessary, and maintenance is kept to a minimum; the GD10P monitors and accounts for changes in the optical path. The heated mirror and lens prevent condensation, and the GD10P continually self-tests, providing early warning of dirt on optics.

The Solid State IR source provides better long-term performance than filament lamps. Suitable for harsh environments with Stainless Steel housing and long-lasting. The warranty is five years for the detector and fifteen years for the solid-state IR optics.

Versions with the OLCT 60 gas transmitter are available, providing a local display of readings.

Features

  • Communications 4-20mA and HART
  • Dual skin weather protector – no filters/gauzes or sinters
  • SIL 2/3 certified
  • Ingress Protection IP66/IP67
  • Operating temperature -40°C to +65°C
  • Size 264 x 104 x 106 mm. Weight 2.9 kg, packed gross 4.03kg
  • Manufacturer Teledyne Oldham, previously Simrad Optronics
  • HS code 9027101000. Country of origin France

A firmware update adds the following capabilities

  • Overscale, or scaling, is now configurable
  • T90 can be configured between 1 and 9 seconds
  • Configurable current output value when switching on the re-zero
  • Configuration of the activation state of re-zero and auto-zero
  • Extended diagnostics

The GD10P has been proven in the field, among countless real-life applications, for instance:

  • Detection of propane at industrial welding stations
  • Detection of ethanol when monitoring the storage of perfume essence

Enquire About This Product

Title Size
GD10P Brochure 61 KB
GD10 CO2 Brochure 87 KB
GD10P FAQs 95 KB
GD10P Features Benefits 112 KB
GD10P Operating Manual 4 MB
GD10P ATEX Certificate 259 KB
GD10P NMETRO Certificate 624 KB
GD10P accessories 160 KB

Additional information

Weight 0.09 kg

Ordering Information

The detector includes a weather protection kit. Sample flow tube and duct mount kit are to be ordered separately.

CH4 Methane

GD10-P00-17BG-0BH-00 GD10P Detector CH4 Methane 100% Vol., SS 316L, CSA, 4-20mA, source, HART (Config 3052)
GD10-P00-17BG-0XH-00 GD10P Detector CH4 Methane 100% Vol., SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2849)
GD10-P00-17DG-0BH-00 GD10P Detector CH4 Methane 100% LEL (5% Vol.), SS 316L, CSA, 4-20mA, source, HART (Config 2886)
GD10-P00-17DG-0BJ-00 GD10P Detector CH4 Methane 100% LEL (5% Vol.), SS 316L, CSA, 4-20mA, sink, HART
GD10-P00-17DG-0XH-00 GD10P Detector CH4 Methane 100% LEL (5% Vol.), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2873)
GD10-P00-17DG-0XJ-00 GD10P Detector CH4 Methane 100% LEL (5% Vol.), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, sink, HART (Config 2867)
GD10-P00-17EG-0XH-00 GD10P Detector CH4 Methane 100% LEL (4.4% Vol.), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2863)

CH4 (Bio)

GD10-P00-18BG-0XH-00 GD10P Detector CH4 Methane 100% Vol. (Biogas), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2855)
GD10-P00-18BG-0XJ-00 GD10P Detector CH4 Methane 100% Vol. (Biogas), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, sink, HART

CH4 (Other)

GD10-P00-81BG-0BH-00 GD10P Detector CH4 Methane 100% VOL. (HC immune), SS316, CSA, 4-20mA, source, HART
GD10-P00-81BG-0XH-00 GD10P CH4 Methane 100% VOL. (HC immune), SS316, ATEX, IECEx, 4-20mA, source, HART

CH4O Methanol

GD10-P00-19DG-0XH-00 GD10P Detector CH4O Methanol 100% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2891)
GD10-P00-19DG-0XJ-00 GD10P Detector CH4O Methanol 100% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, sink, HART (Config 3055)

CO2 Carbon dioxide

GD10-P00-23AN-0XH-00 GD10P Detector CO2 Carbon dioxide 10000 ppm, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2841)
GD10-P00-23BC-0BH-00 GD10P Detector CO2 Carbon dioxide 5% Vol., SS 316L, CSA, 4-20mA, source, HART (Config 3018)
GD10-P00-23BC-0XH-00 GD10P Detector CO2 Carbon dioxide 5% Vol., SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2901)
GD10-P00-23BD-0XH-00 GD10P Detector CO2 Carbon dioxide 10% Vol., SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2934)
GD10-P00-23BH-0BH-00 GD10P Detector CO2 Carbon dioxide 3% Vol., SS 316L, CSA, 4-20mA, source, HART
GD10-P00-23BH-0XH-00 GD10P Detector CO2 Carbon dioxide 3% Vol., SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2845)
GD10-P00-23BJ-0XH-00 GD10P Detector CO2 Carbon dioxide 25% Vol., SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2956)
GD10-P00-24BC-0BH-00 GD10P Detector CO2 Carbon dioxide 5% Vol. (CH4 immune), SS 316L, CSA, 4-20mA, source, HART (Config 2975)
GD10-P00-24BC-0XH-00 GD10P Detector CO2 Carbon dioxide 5% Vol. (CH4 immune), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2859)
GD10-P00-24BG-0XH-00 GD10P CO2 Carbon dioxide 100% Vol. (CH4 immune), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2909)

C2H2 Acetylene

GD10-P00-02DG-0XH-00 GD10P Detector C2H2 Acetylene 100% LEL SS 316L, ATEX, IECEx, INMETRO, 4- 20mA, source, HART (Config 2905)

C2H4 Ethylene

GD10-P00-03DG-0XH-00 GD10P Detector C2H4 Ethylene 100% LEL SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2879)
GD10-P00-03DG-0XJ-00 GD10P Detector C2H4 Ethylene 100% LEL SS 316L, ATEX, IECEx, INMETRO, 4-20mA, sink, HART

C2H6 Ethane

GD10-P00-56DG-0XH-00 GD10P Detector C2H6 Ethane 100% LEL (2.4% Vol.), SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2873)
GD10-P00-56DG-0XJ-00 GD10P Detector C2H6 Ethane 100% LEL (2.4% Vol.), SS 316L, ATEX, IECEx, 4-20mA, sink, HART (Config 2867)

C2H6O Ethanol

GD10-P00-05DG-0XH-00 GD10P Detector C2H6O Ethanol 100% LEL (3.3%Vol) SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2930)
GD10-P00-05EG-0XH-00 GD10P Detector C2H6O Ethanol 100% LEL (3.1% Vol) SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 3021)

C3H6 Propene

GD10-P00-07DG-0XH-00 GD10P Detector C3H6 Propene 100% LEL SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2926)

C3H6O Acetone

GD10-P00-08DG-0XH-00 GD10P Detector C3H6O Acetone 100% LEL SS316, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2922)

C3H8 Propane

GD10-P00-09DG-0BH-00 GD10P Detector C3H8 Propane 100% LEL (2.2% Vol.), SS 316L, CSA, 4-20mA, source, HART (Config 3015)
GD10-P00-09DG-0XH-00 GD10P Detector C3H8 Propane 100% LEL (2.2% Vol.), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2872)
GD10-P00-09DG-0XJ-00 GD10P Detector C3H8 Propane 100% LEL (2.2% Vol.), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, sink, HART (Config 2960)
GD10-P00-09EG-0XH-00 GD10P Detector C3H8 Propane 100% LEL (1.7% Vol.), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2997)

C3H8 (2)

GD10-P00-80BG-0BH-00 GD10P Detector C3H8 Propane 100% VOL. (CH4 immune), SS316, CSA, 4-20mA, source, HART
GD10-P00-80BG-0XH-00 GD10P Detector C3H8 Propane 100% VOL. (CH4 immune), SS316, ATEX, IECEx, 4-20mA, source, HART

C5H12 Pentane

GD10-P00-11DG-0XH-00 GD10P Detector C5H12 Pentane 100% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 3010)

C6H12 Cyclohexane

GD10-P00-73DG-0XH-00 GD10P Detector C6H12 Cyclohexane 100% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2992)

C6H14 Hexane

GD10-P00-12DG-0XH-00 GD10P Detector C6H14 Hexane 100% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2949)

C6H6 Benzene

GD10-P00-13DG-0XH-00 GD10P Detector C6H6 Benzene 100% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2943)

C7H8 Toluene

GD10-P00-14DG-0XH-00 GD10P Detector C7H8 Toluene 100% LEL (1.2% Vol.), SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 3005)

C8H8 Styrene

GD10-P00-15DG-0XH-00 GD10P Detector C8H8 Styrene 100% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 3062)

n-C4H10 n-Butane

GD10-P00-38DG-0XH-00 GD10P Detector n-C4H10 n-Butane 100% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-20mA, source, HART (Config 2938)

Accessories

Bracket

499-811176 Adapter plate
599-811547 Adapter plate, footprint conversion GD100-GD10P

Installation

AS053-X SS316L mounting plate for DM/DMI/DG/DGI/GD10 (Add U-bolts ref. AS057-X or AS058-X)
AS057-X 2 x SS316 U-bolts for 2″ pipe
AS058-X 2 x SS316 U-bolts for 2.5″ pipe
AS049 Wall-mounting adapter plate BT05 (EX05 series) / BT606 (DM/DMi series) / BT10
499-811938 Duct mounting kit
499-816867 Pipe mounting plate, kit, M8x2,5″ A4 (for 2″ pole)
AS052 Fixing sling
AS034-X Measuring chamber flow for sampling applications
499-816816 TAG 1x80x20mm, SS 316, CUSTOM TEXT, including washer and split ring (for GD10
499-816915 TAG 1x75x30mm, SS 316 CUSTOM TEXT, including washer and split ring (for GD10
AS215 Detector stainless steel tag plate (2x80x40mm) SS 316, CUSTOM TEXT
6343489 Cable-gland kit, M20, stainless steel, for armoured cable
6343493 Cable-gland kit, M20, stainless steel, for unarmoured cable
6343495 Cable-gland kit, M20, nickelled brass, for armoured cable
6343499 Cable-gland kit, M20, nickelled brass, for unarmoured cable

Protection

499-813397 Mosquito net, steel mesh
499-815712 Sunshade
599-816841 Sunshade, vertical mounting (pipe mounting plate, kit required)

Maintenance

599-818154 Gas test socket GD10P
499-810874 Sample flow housing for GD10P. This is also used for testing / Calibration check
140-816580 Hand-held terminal for GD10P & GD10PE. Special tool – subject to training. Supplied in carrying case. RS485 connection, not HART
TLU600 IS Infra Red Remote Control Unit with a battery charger
TLH710 HART Remote Control Unit with a battery charger
TLH720 IS HART Remote Control Unit with a battery charger

Display

GD10P-DISPLAY-A-ATEX Field Mounted Loop Powered Indicator with Membrane Switches, Copper-free Aluminum, Blue Epoxy Painted, ATEX, IECEx, IP68, 3xM20 entries, supplied with 1 stopping plug.

GD10P-DISPLAY-A-CSA Field Mounted Loop Powered Indicator with Membrane Switches, Copper-free Aluminum, Blue Epoxy Painted, CSA, NEMA4X, 3×3/4NPT entries, supplied with 1 stopping plug.

GD10P-DISPLAY-X-ATEX Field Mounted Loop Powered Indicator with Membrane Switches, Stainless steel, ATEX, IECEx, IP68, 3xM20 entries, supplied with 1 stopping plug.

GD10P-DISPLAY-X-CSA Field Mounted Loop Powered Indicator with Membrane Switches, SS316, CSA, NEMA4X, 3×3/4NPT entries, supplied with 1 stopping plug.

B105507 EX plug stopping ATEX/IECEx/FM, SS316, M20x150 for GD10p-Display-xx-ATEX
B105508 EX plug stopping ATEX/IECEx/FM, SS316, 3/4″NPT for GD10p-Display-xx-CSA
6125305 Mounting bracket 175MM for GD10P-DISPLAY

GD10P Display Modules: accept 4-20 mA signal from GD10P or other Teledyne gas

R-5000AL-2 Display Module, Aluminum Enclosure
R-5000ALR-2 Display Module with Relays, Aluminum Enclosure
R-5000SS-2 Display Module, Stainless Steel Enclosure
R-5000SSR-2 Display Module with Relays, Stainless Steel Enclosure
899-M20075-BNP M20 male to 3/4 NPT male Adaptor, nickel-plated brass
899-M20075-MSS M20 male to 3/4 NPT male Adaptor, stainless steel

Spares

373-901337 Terminal GD10P/PE/L 4-5
373-903947 Terminal GD10P/PE/L 1-3
499-810913 Standard front cover. Weather Protection, GD10P
499-816584 Back cover, kit GD10P/PE/L
540-903951 Ring Sealing (Ø58×3) for Sample flow GD10P
540-903952 Ring Sealing (Ø60×3) for Sample flow GD10PE
540-903954 Ring Sealing (Ø65×2) for Back cover GD10P/PE/L
541-903950 Ex plug stopping M20
599-810646 Test nipple, GD10P
599-811937 Test nipple for GD10P Duct mount
599-904176 Protective Cap for test nipple GD10P/PE

Past part numbers 

128-810867.2 GD10P 0-100 % LEL Methane 5 sec. source
128-813367 GD10P-UL 100 % LEL Methane 5 sec. source
128-810908.4 GD10C 0-100 % LEL Methane 5 sec. source
128-811208.8

Enquire About This Product