Teledyne Simtronics GD10P CO2 Infrared Point Gas Detector

Code: GD10-P00-23BC-0XH-00
  • Selectable response rate
  • Early dirty optics warning for improved preventative maintenance
  • Certified for use in a SIL 2 system

In StockMake An Enquiry

The GD10P-CO2 uses state-of-the-art IR gas measurement to give a fast, reliable response. The GD10P has set the standard for gas detection in the areas of safety, stability and low maintenance.

The GD10P comes with a 5-year warranty. The GD10P-CO2 has been designed with features that provide an effective response to the detection of CO2 in a wide range of industrial environments, from boiler plant rooms to offshore petrochemical installations.

The GD10P-CO2 differs from all other point infrared gas detectors because it utilises silicon-based solid-state sources.

The complete optomechanical design and construction is so stable that an ultra-fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs.

Offering the longest combined detector and IR source warranty on the market. Supplied with worldwide hazardous area approvals. An industry standard HART interface is used for configuration of special fault levels as well as access to extended maintenance data.

Features

  • Solid state IR sources (SimSource) for superior long-term performance compared to filament lamps.
  • Dual-layer weather protector (No mesh, gauze, hydrophobic filters or sinters = No delay, no failure on demand).
  • Low power consumption reduces the load on the UPS.
  • Independently heated mirror and lens for high-performance detection in rough environmental conditions.
  • The integral termination compartment enables reduced installation time, and the unit is ready out of the box.
  • No recalibration is required; it monitors and accounts for all changes in the optical path, thanks to its true dual-path, double-compensation optical design.

Other Versions

  • GD10P Combustible gas detector
  • The PE model detects flammable gas in large volumes of air

Order Information

ATEX / IECEx Approved
GD10-P00-23AN-0XH-00 GD10P CO2, Carbon dioxide 10,000 ppm, SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2841)
GD10-P00-23BH-0XH-00 GD10P CO2, Carbon dioxide 3% Vol., SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2845)
GD10-P00-23BC-0XH-00 GD10P CO2, Carbon dioxide 5% Vol., SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2901)
GD10-P00-23BD-0XH-00 GD10P CO2, Carbon dioxide 10% Vol., SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2934)
GD10-P00-23BJ-0XH-00 GD10P CO2, Carbon dioxide 25% Vol., SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2956)
GD10-P00-24BC-0XH-00 GD10P CO2, Carbon dioxide 5% Vol. (CH4, immune), SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2859)
GD10-P00-24BG-0XH-00 GD10P CO2, Carbon dioxide 100% Vol. (CH4, immune), SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2909)
CSA Approved
GD10-P00-23AN-0BH-00 GD10P CO2, Carbon dioxide 10,000 ppm, SS 316L, CSA, 4-20mA, source, HART
GD10-P00-23BH-0BH-00 GD10P CO2, Carbon dioxide 3% Vol., SS 316L, CSA, 4-20mA, source, HART
GD10-P00-23BC-0BH-00 GD10P CO2, Carbon dioxide 5% Vol., SS 316L, CSA, 4-20mA, source, HART (Config 3018)
GD10-P00-23BD-0BH-00 GD10P CO2, Carbon dioxide 10% Vol., SS 316L, CSA, 4-20mA, source, HART
GD10-P00-23BJ-0BH-00 GD10P CO2, Carbon dioxide 25% Vol., SS 316L, CSA, 4-20mA, source, HART
GD10-P00-24BC-0BH-00 GD10P CO2, Carbon dioxide 5% Vol. (CH4, immune), SS 316L, CSA, 4-20mA, source, HART (Config 2975)
GD10-P00-24BG-0BH-00 GD10P CO2, Carbon dioxide 100% Vol. (CH4, immune), SS 316L, CSA, 4-20mA, source, HART
UL Approved
GD10-P00-23AN-0CH-00 GD10P CO2, Carbon dioxide 10,000 ppm, SS 316L, UL, 4-20mA, source, HART
GD10-P00-23BH-0CH-00 GD10P CO2, Carbon dioxide 3% Vol., SS 316L, UL, 4-20mA, source, HART
GD10-P00-23BC-0CH-00 GD10P CO2, Carbon dioxide 5% Vol., SS 316L, UL, 4-20mA, source, HART
GD10-P00-23BD-0CH-00 GD10P CO2, Carbon dioxide 10% Vol., SS 316L, UL, 4-20mA, source, HART
GD10-P00-23BJ-0CH-00 GD10P CO2, Carbon dioxide 25% Vol., SS 316L, UL, 4-20mA, source, HART
GD10-P00-24BC-0CH-00 GD10P CO2, Carbon dioxide 5% Vol. (CH4, immune), SS 316L, UL, 4-20mA, source, HART
GD10-P00-24BG-0CH-00 GD10P CO2, Carbon dioxide 100% Vol. (CH4, immune), SS 316L, UL, 4-20mA, source, HART
Accessories
Bracket
499-811176 Adapter plate
599-811547 Adapter plate, footprint conversion GD100-GD10P
Installation
AS053-X SS316L mounting plate for DM/DMI/DG/DGI/GD10 (Add U-bolts ref. AS057-X or AS058-X)
AS057-X 2 x SS316 U-bolts for 2″ pipe
AS058-X 2 x SS316 U-bolts for 2.5″ pipe
AS049 Wall-mounting adapter plate BT05 (EX05 series) / BT606 (DM/DMi series) / BT10
499-811938 Duct mounting kit
499-816867 Pipe mounting plate, kit, M8x2,5″ A4 (for 2″ pole)
AS052 Fixing sling
AS034-X Measuring chamber flow for sampling applications
499-816816 TAG 1x80x20mm, SS 316, CUSTOM TEXT, including washer and split ring (for GD10)
499-816915 TAG 1x75x30mm, SS 316 CUSTOM TEXT, including washer and split ring (for GD10)
AS215 Detector stainless steel tag plate (2x80x40mm) SS 316, CUSTOM TEXT
6343489 Cable-gland kit, M20, stainless steel, for armoured cable
6343493 Cable-gland kit, M20, stainless steel, for unarmoured cable
6343495 Cable-gland kit, M20, nickelled brass, for armoured cable
6343499 Cable-gland kit, M20, nickelled brass, for unarmoured cable
Protection
499-813397 Mosquito net, steel mesh
499-815712 Sunshade
599-816841 Sunshade, vertical mounting (pipe mounting plate, kit required)
Maintenance
599-818154 Gas test socket GD10P
499-810874 Sample flow housing for GD10P. This is also used for testing / Calibration check
140-816580 Hand-held terminal for GD10P & GD10PE. Special tool – subject to training. Supplied in a carrying case. RS-485 connection, not HART
TLU600 IS Infra Red Remote Control Unit with a battery charger
TLH710 HART Remote Control Unit with a battery charger
TLH720 IS HART Remote Control Unit with a battery charger
Display
GD10P-DISPLAY-A-ATEX Field-mounted loop-powered indicator with Membrane Switches, Copper-free aluminium, Blue epoxy-painted, ATEX, IECEx, IP68, 3xM20 entries, supplied with 1 stopping plug.
GD10P-DISPLAY-A-CSA Field-mounted loop-powered indicator with Membrane Switches, Copper-free aluminium, Blue epoxy-painted, CSA, NEMA4X, 3×3/4NPT entries, supplied with 1 stopping plug.
GD10P-DISPLAY-X-ATEX Field-mounted loop-powered indicator with Membrane Switches, Stainless steel, ATEX, IECEx, IP68, 3xM20 entries, supplied with 1 stopping plug.
GD10P-DISPLAY-X-CSA Field Mounted Loop Powered Indicator with Membrane Switches, SS316, CSA, NEMA4X, 3×3/4NPT entries, supplied with 1 stopping plug.
B105507 EX plug stopping ATEX/IECEx/FM, SS316, M20x150 for GD10p-Display-xx-ATEX
B105508 EX plug stopping ATEX/IECEx/FM, SS316, 3/4″NPT for GD10p-Display-xx-CSA
6125305 Mounting bracket 175MM for GD10P-DISPLAY
GD10P Display Modules: accept 4-20 mA signal from GD10P or other Teledyne gas
R-5000AL-2 Display Module, Aluminium Enclosure
R-5000ALR-2 Display Module with Relays, Aluminium Enclosure
R-5000SS-2 Display Module, Stainless Steel Enclosure
R-5000SSR-2 Display Module with Relays, Stainless Steel Enclosure
899-M20075-BNP M20 male to 3/4 NPT male Adaptor, nickel-plated brass
899-M20075-MSS M20 male to 3/4 NPT male Adaptor, stainless steel
Spares
373-901337 Terminal GD10P/PE/L 4-5
373-903947 Terminal GD10P/PE/L 1-3
499-810913 Standard front cover. Weather Protection, GD10P
499-816584 Back cover, kit GD10P/PE/L
540-903951 Ring Sealing (Ø58×3) for Sample flow GD10P
540-903952 Ring Sealing (Ø60×3) for Sample flow GD10PE
540-903954 Ring Sealing (Ø65×2) for Back cover GD10P/PE/L
541-903950 Ex plug stopping M20
599-810646 Test nipple, GD10P
599-811937 Test nipple for GD10P Duct mount
599-904176 Protective Cap for test nipple GD10P/PE

Enquire About This Product

Title Size
GD10P CO2 Datasheet 243 KB

Additional information

Weight 0.09 kg

Specifications

General
Detection method IR-absorption, dual wavelength, dual path
Ir-source Solid state IR source, 50Hz flash
Gases detected CO2
Self-test Continuous
Calibration Factory set, no field recalibration
Configuration Hart (response time, fault levels)
Performance
Accuracy ±5% Fs between 0-50 % reading
±7% Fs between 50-80 % reading
Response time T20 = 1 sec. (0.3 Sec)
Configurable T50 = 2.5 Sec (0.7 Sec)
T90 = 6 sec (1.6 Sec)
Output signal
Standard Current source 4 – 20 mA, max. Load Impedance 500 ohm
Option Current sink 4 – 20 mA
Hart Maintenance and configuration
Detector warnings: Configurable (HART)
Early clean optics – Pre warning (2 mA)
Dirty optics – Dirt accumulation (1 mA)
Detector failure – Internal fault (0 mA)
Electrical
Power supply 24V dc, range (18 – 32v dc)
Power consumption Approx. 3.5 W
Connection 3 Wires (0.5mm2 – 2.5 mm2)
Cable entry M20 exe cable gland
Temperature range
Storage -40°C to + 70°c (-40°f to +158°F)
Operating -40°C to + 60°C (-40°F to +140°F)
Humidity (operation) 100% RH
Explosion-proof housing
Protection category IP66/IP67 din 40050
Housing material Stainless steel sis2343 (astm316)
Weight Approx. 2.9 Kg
Dimensions (lxwxh) 251 X 1 04 x 1 05 (mm)
9.89 X 4.1 X 4.13 (Inches)
Warranty 5 Years full warranty on a complete instrument
15 Years warranty on the ir-sources
Approvals
ATEX / IECEX / INMETRO II 2G Ex de IIC T6 Gb
CSA Ex de IIC T6 (Canada only)
Class I, Division 2, Groups A, B, C, and D (USA and Canada)
Other SIL2 (Software SIL3), ABS, MED
Versions Standard ranges (volume) :
10000Ppm (1%) , 3%, 5% 10% and 100%
The 0-100% volume is also compensated for Methane interference.
Front cover Required, select one:
Weather protection – For standard point detector
Sample flow housing – For sampling systems and testing
Duct mount kit – For through-wall installation
Accessories
Mosquito net Extra insect protection
Sun shade Shielding for extreme radiation exposure

Enquire About This Product