Simtronics DG-TT7 and DG-RT7 series by Teledyne is part of the DG7 family of gas detectors. All have a common mode of operation, for standardised training and maintenance.
The range is split into two categories:
- DG-TT7-S uses a solid-state metal oxide semiconductor sensor. For the detection of Hydrogen Sulphide. DG-RT7-S are the Syntel models.
- DG-TT7-K has a thermal conductivity sensor to monitor explosions risks induced by the presence of flammable gases or vapours (hydrogen, hydrocarbons, alcohol, etc). DG-RT7-K are the Syntel models. The principle is very stable and able to operate with high gas concentrations. In this configuration, the presence of oxygen is not essential, and catalytic poisoning is not an issue.
Microprocessor driven, configurable using a wireless hand-held terminal (TLU) or by using hard wired HART protocol option, providing installation options and reduced service costs. Relay operation and alarm levels can be set using the TLU which is hazardous area approved.
Common Features
- Easy to use
- Ultrabright 4 digit LED display, shows local status by display colour & alarm level.
- 4-20mA output & 2 x configurable relays
- Compatible with most controllers and PLC’s
- Power supply 24V DC
- Housing corrosion resistant Stainless Steel
- Ingress Protection IP66
- Approvals ATEX & IECEx
- Range previously by Simrad Optronics
Output Signal Options
- HART Protocol 7th edition (facilitating nonproprietary interface)
- Lonworks (Syntel)
- 0-22mA (User configurable) included with DG-TT7-S
H2S Hydrogen sulphide DG-TT7/S, Semiconductor (MOS) toxic gas detectors, SS316L, local display
DG-TT7-31AE-SXC-C0 MultiTox detector 20ppm H2S, MOS, Configurable output, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7-31AE-SXH-C0 MultiTox detector 20ppm H2S, MOS, HART protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7-31AF-SXC-C0 MultiTox detector 50ppm H2S, MOS, Configurable output, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7-31AF-SXH-C0 MultiTox detector 50ppm H2S, MOS, HART protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7-31AG-SXC-C0 MultiTox detector 100ppm H2S, MOS, Configurable output, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7-31AG-SXH-C0 MultiTox detector 100ppm H2S, MOS, HART protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7/K Thermal conductivity gas detectors, SS316L, local display
H2 Hydrogen
DG-TT7-30BC-KXC-K0 MultiTox detector 5% Vol. H2, Catharometer, Configurable output, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7-30BC-KXH-K0 MultiTox detector 5% Vol. H2, Catharometer, HART protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7-30BE-KXC-K0 MultiTox detector 20% Vol. H2, Catharometer, Configurable output, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7-30BE-KXH-K0 MultiTox detector 20% Vol. H2, Catharometer, HART protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7-30BG-KXC-K0 MultiTox detector 100% Vol. H2, Catharometer, Configurable output, SS 316L (Cert. ATEX Ex d – IECEx)
DG-TT7-30BG-KXH-K0 MultiTox detector 100% Vol. H2, Catharometer, HART protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-RT7/S, Semiconductor (MOS) toxic gas detectors for SYNTEL, SS316L, local display
H2S Hydrogen sulfide
DG-RT7-31AE-SXL-C0 MultiTox detector 20ppm H2S, MOS, LON protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-RT7-31AF-SXL-C0 MultiTox detector 50ppm H2S, MOS, LON protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-RT7-31AG-SXL-C0 MultiTox detector 100ppm H2S, MOS, LON protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-RT7/K, Thermal conductivity gas detectors for SYNTEL, SS316L, local display
H2 Hydrogen
DG-RT7-30BC-KXL-K0 MultiTox detector 5% Vol. H2, Catharometer, LON protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-RT7-30BE-KXL-K0 MultiTox detector 20% Vol. H2, Catharometer, LON protocol, SS 316L (Cert. ATEX Ex d – IECEx)
DG-RT7-30BG-KXL-K0 MultiTox detector 100% Vol. H2, Catharometer, LON protocol, SS 316L (Cert. ATEX Ex d – IECEx)
Spare sensors (MOS and thermal conductivity)
DM-ST6-30BC-KA0-K0 MultiTox sensor, 5% Vol. H2, Catharometer, for aluminium DM6 Series (Cert. ATEX Ex d – IECEx)
DM-ST6-30BC-KX0-K0 MultiTox sensor, 5% Vol. H2, Catharometer, for SS 316L DG7 Series (Cert. ATEX Ex d – IECEx)
DM-ST6-30BE-KA0-K0 MultiTox sensor, 20% Vol. H2, Catharometer, for aluminium DM6 Series (Cert. ATEX Ex d – IECEx)
DM-ST6-30BE-KX0-K0 MultiTox sensor, 20% Vol. H2, Catharometer, for SS 316L DG7 Series (Cert. ATEX Ex d – IECEx)
DM-ST6-30BG-KA0-K0 MultiTox sensor, 100% Vol. H2, Catharometer, for aluminium DM6 Series (Cert. ATEX Ex d – IECEx)
DM-ST6-30BG-KX0-K0 MultiTox sensor, 100% Vol. H2, Catharometer, for SS 316L DG7 Series (Cert. ATEX Ex d – IECEx)
H2S Hydrogen sulfide
DM-ST6-31AE-SA0-C0 MultiTox sensor, 20ppm H2S, MOS, for aluminium DM6 Series
DM-ST6-31AE-SX0-C0 MultiTox sensor, 20ppm H2S, MOS, for SS 316L DG7 Series
DM-ST6-31AF-SA0-C0 MultiTox sensor, 50ppm H2S, MOS, for aluminium DM6 Series
DM-ST6-31AF-SX0-C0 MultiTox sensor, 50ppm H2S, MOS, for SS 316L DG7 Series
DM-ST6-31AG-SA0-C0 MultiTox sensor, 100ppm H2S, MOS, for aluminium DM6 Series
DM-ST6-31AG-SX0-C0 MultiTox sensor, 100ppm H2S, MOS, for SS316L DG7 series