Oldham OLCT 80 Fixed Gas Detector

Code: OLCT 80
  • Wireless or non-wireless models
  • Flammable, Toxic Gases & Oxygen
  • Low power requirement

In StockMake An Enquiry

The Oldham OLCT 80 gas detector by Teledyne provides wireless connectivity in ATEX 1 zones, eliminating the need for wiring.

A versatile transmitter supporting all gas detection principles: catalytic, electrochemical, infrared and semiconductor. Compatible with all Industrial Scientific sensors. Available in wireless or non-wireless versions.

The transmitter is housed in epoxy-coated aluminium, and the sensor is housed in stainless steel. The local display shows readings, and four lamps indicate status: green shows operation ok, yellow denotes fault and red for alarm.

A single fault relay and two gas alarm relays are included, operated by the sensor electronics or supplementary inputs or from the MX62 central unit or the control system to which the sensor is connected. The OLCT 80 can serve as a standalone unit, an indisputable advantage in a classified explosion risk zone.

Features

  • An infrared remote controller and onboard LCD for non-intrusive, one-person calibration
  • Flameproof or intrinsically safe sensors
  • Cable entries M20 x 4 and M25 x 2 (more optional)
  • Suitable for explosive areas
  • Flexible input/output options, including analogue, TOR and Modbus RS485
  • XP IR infrared sensor option for CO2
  • Frequency 2.4 GHz (EU) range 2 miles & 900 MHz (USA) range 6 miles
  • Robust mesh network topology
  • Up to 49 devices per network
  • Approvals ATEX complies with EN 50270
  • Operating temperature – 20 °C to + 60 °C
  • Weight OLCT 80: 3.5 kg. IR version: 5.3 kg

Enquire About This Product

Title Size
OLCT 80 Brochure 203 KB
OLCT 80 Wireless Brochure 126 KB
OLCT 80 Manual 2 MB

Additional information

Weight 0.09 kg

Ordering Information

Base Models

6513542 OLCT80-XP Transmitter OLCT 80 – flameproof – with on-board XP sensor – approved Ex d IIC T5 to T6 Gb
6513646 OLCT80-W-XP (a) Transmitter OLCT 80 – flameproof – Wireless 2,4GHz – with on-board XP sensor – approved Ex d IIB T5 Gb
OLCT80-XPA Transmitter OLCT 80 – flameproof – with on-board poison resistant XP sensor – approved Ex d IIC T5 to T6 Gb
OLCT80-W-XPA (a) Transmitter OLCT 80 – flameproof – Wireless 2,4GHz – with on-board poison resistant XP sensor – approved Ex d IIB T5 Gb
OLCT80-XPIR Transmitter OLCT 80 – flameproof – with on-board XPIR sensor – approved Ex d IIC T5 to T6 Gb
OLCT80-W-XPIR Transmitter OLCT 80 – flameproof – Wireless 2,4GHz – with on-board XPIR sensor -approved Ex d IIB T5 Gb
6513551 OLCT80D-XP Transmitter OLCT 80 – flameproof – with remote XP sensor – approved Ex d IIC T5 to T6 Gb
6513653 OLCT80D-W-XP (a) Transmitter OLCT 80 – flameproof – Wireless 2,4GHz – with remote XP sensor -approved Ex d IIB T5 Gb
OLCT80D-XPA Transmitter OLCT 80 – flameproof – with remote poison resistant XP sensor -approved Ex d IIC T5 to T6 Gb
OLCT80D-W-XPA (a) Transmitter OLCT 80 – flameproof -Wireless 2,4GHz – with remote poison resistant XP sensor – approved Ex d IIB T5 Gb
OLCT80D-XPIR Transmitter OLCT 80 – flameproof – with remote poison XPIR sensor – approved Ex d IIC T5 to T6 Gb
OLCT80D-W-XPIR (a) Transmitter OLCT 80 – flameproof – Wireless 2,4GHz – with remote XPIR sensor -approved Ex d IIB T5 Gb
OLCT80-IS Transmitter OLCT 80 – flameproof – with on-board ISP sensor – approvedé Ex d[ia] is IIC T4
OLCT80D-IS Transmitter OLCT 80 – flameproof – with remote IS sensor – approved Ex d[ia] ia IIC T4
OLCT80-W-IS (a) Transmitter OLCT 80 – flameproof – Wireless 2,4GHz – with on-board IS sensor -approved Ex d[ia] ia IIC T4
OLCT80D-W-IS (a) Transmitter OLCT 80 – flameproof – Wireless 2,4GHz – with remote IS sensor -approved Ex d[ia] ia IIC T4

(a) needs a Master receipt module by a network (B301563) 2.4 GHz, RS485 Modbus output/repeater or function

Replacement sensors

6313685 XP sensor for OLCT 20/40/50/60/80, range 0-100% LEL (catalytic)
6313772 XP sensor for OLCT 20/40/50/60/80, Chlorure de Méthyl(ène), range 0-500ppm, (Semiconductor)
6313773 XP sensor for OLCT 20/40/50/60/80, R22 (0-2000ppm) – R12 (0-1%) (Semi-conductor) 372,00
6313774 XP sensor for OLCT 20/40/50/60/80, R134a, R11, R23, R143a, R404a, R507, R410a, R32, R407c, R408a, (Semi-conductor)
6313775 XP sensor for OLCT 20/40/50/60/80, COV 0-500ppm, (Semi-conductor)
6313872 XP sensor for OLCT 20/40/50/60/80, range 0-100% LEL butadiène/acétylène (catalytic)
6313974 XP sensor for OLCT 20/40/50/60/80, range 0-100% LEL AP (catalytic)

ASH3 Arsine
6313738 IS sensor for OLCT 20/40/50/60/80, ASH3, range 0-1ppm (electrochemical)

BR2
6313865 IS sensor for OLCT 20/40/50/60/80, Br2, range 0-300ppm (electrochemical)
6313912 IS sensor for OLCT 20/40/50/60/80, Br2, range 0-20ppm (electrochemical)

C2H6S
B301168 XP sensor for OLCT 20/40/50/60/80, Ethylmercaptan 0-100ppm (electrochemical)

CH2O
6313972 IS sensor for OLCT 20/40/50/60/80, Formaldéhyde, range 0-50ppm (electrochemical)

CH4 Methane
6313687 XP sensor for OLCT 20/40/50/60/80, range 0-100% vol CH4 (Catharometric)

CH4S
6313997 XP sensor for OLCT 20/40/50/60/80, Méthylmercaptan 0-30ppm (electrochemical)
6314186 XP sensor for OLCT 20/40/50/60/80, Méthylmercaptan 0-100ppm (electrochemical)

Cl2 Chlorine
6313734 IS sensor for OLCT 20/40/50/60/80, Cl2, range 0-10ppm (electrochemical)

ClO2 Chlorine dioxide
6313740 IS sensor for OLCT 20/40/50/60/80, ClO2, range 0-3ppm (electrochemical)

CO Carbon monoxide
6313690 XP sensor for OLCT 20/40/50/60/80, CO, range 0-100ppm (electrochemical)
6313691 XP sensor for OLCT 20/40/50/60/80, CO, range 0-300ppm (electrochemical)
6313692 XP sensor for OLCT 20/40/50/60/80, CO, range 0-1000ppm (electrochemical)
6313693 XP sensor for OLCT 20/40/50/60/80, CO, range 0-1000ppm compensated H2 (electrochemical)
6313694 IS sensor for OLCT 20/40/50/60/80, CO, range 0-1000ppm compensated H2 (electrochemical)
6313711 IS sensor for OLCT 20/40/50/60/80, CO, range 0-100ppm (electrochemical)
6313712 IS sensor for OLCT 20/40/50/60/80, CO, range 0-300ppm (electrochemical)
6313713 IS sensor for OLCT 20/40/50/60/80, CO, range 0-1000ppm (electrochemical)
6313875 XP sensor for OLCT 20/40/50/60/80, CO, range 0-2000ppm (electrochemical)
6313885 XP sensor for OLCT 20/40/50/60/80, CO, range 0-100ppm compensated H2 (electrochemical)
6314006 XP sensor for OLCT 20/40/50/60/80, CO, range 0-1%vol (electrochemical)
6314007 IS sensor for OLCT 20/40/50/60/80, CO, range 0-1% vol (electrochemical)
B300902 XP sensor for OLCT 20/40/50/60/80, CO, range 0-300ppm compensated H2 (electrochemical)

CO2 Carbon dioxide
6314100 XP sensor for OLCT 60 XPIR & OLCT 80 XPIR, range 0-5% vol. CO2 (InfraRed)
6314101 XP sensor for OLCT 60 XPIR & OLCT 80 XPIR, range 0-10% vol. CO2 (InfraRed)
6314146 XP sensor for OLCT 60 XPIR & OLCT 80 XPIR, range 0-100% vol. CO2 (InfraRed)

COCl2 Phosgene
6313736 IS sensor for OLCT 20/40/50/60/80, COCl2, range 0-1ppm (electrochemical)
6313746 IS sensor for OLCT 20/40/50/60/80, ETO, range 0-30ppm (electrochemical)
6313951 IS sensor for OLCT 20/40/50/60/80, ETO, range 0-100ppm (electrochemical)

H2 Hydrogen
6313706 XP sensor for OLCT 20/40/50/60/80, H2, range 0-2000ppm (electrochemical)
6313727 IS sensor for OLCT 20/40/50/60/80, H2, range 0-2000ppm (electrochemical)
6314203 XP sensor for OLCT 20/40/50/60/80, range 0 – 100% vol H2 (Catharometric)

H2S Hydrogen sulfide
6313695 XP sensor for OLCT 20/40/50/60/80, H2S, range 0-30ppm (electrochemical)
6313696 XP sensor for OLCT 20/40/50/60/80, H2S, range 0-100ppm (electrochemical)
6313697 XP sensor for OLCT 20/40/50/60/80, H2S, range 0-1000ppm (electrochemical)
6313716 IS sensor for OLCT 20/40/50/60/80, H2S, range 0-30ppm (electrochemical)
6313717 IS sensor for OLCT 20/40/50/60/80, H2S, range 0-100ppm (electrochemical)
6313718 IS sensor for OLCT 20/40/50/60/80, H2S, range 0-1000ppm (electrochemical)
6313965 XP sensor for OLCT 20/40/50/60/80, H2S nul HC, range 0-30ppm (electrochemical)
6314135 XP sensor for OLCT 20/40/50/60/80, H2S, range 0-50ppm (electrochemical)

HCl Hydrogen chloride
6313730 IS sensor for OLCT 20/40/50/60/80, HCl, range 0-30ppm (electrochemical)
6313731 IS sensor for OLCT 20/40/50/60/80, HCl, range 0-100ppm (electrochemical)

HCN Hydrogen cyanide
6313732 IS sensor for OLCT 20/40/50/60/80, HCN, range 0-10ppm (electrochemical)
6313733 IS sensor for OLCT 20/40/50/60/80, HCN, range 0-30ppm (electrochemical)

HF Hydrogen fluoride
6313739 IS sensor for OLCT 20/40/50/60/80, HF, range 0-10ppm (electrochemical)

N2H4 Hydrazine
6313854 IS sensor for OLCT 20/40/50/60/80, N2H4, range 0-100ppm (electrochemical)

N2H4 Hydrazine
6314242 IS sensor for OLCT 20/40/50/60/80, N2H4, range 0-2ppm (electrochemical)

NH3 Ammonia
6313707 XP sensor for OLCT 20/40/50/60/80, NH3, range 0-100ppm (electrochemical)
6313708 XP sensor for OLCT 20/40/50/60/80, NH3, range 0-1000ppm (electrochemical)
6313728 IS sensor for OLCT 20/40/50/60/80, NH3, range 0-100ppm (electrochemical)
6313729 IS sensor for OLCT 20/40/50/60/80, NH3, range 0-1000ppm (electrochemical)
6313894 XP sensor for OLCT 20/40/50/60/80, NH3, range 0-5000ppm (electrochemical)
6313895 IS sensor for OLCT 20/40/50/60/80, NH3, range 0-5000ppm (electrochemical)
6313968 XP sensor for OLCT 20/40/50/60/80, NH3, range 0-300ppm (electrochemical)

NO Nitric oxide
6313698 XP sensor for OLCT 20/40/50/60/80, NO, range 0-100ppm (electrochemical)
6313699 XP sensor for OLCT 20/40/50/60/80, NO, range 0-300ppm (electrochemical)
6313700 XP sensor for OLCT 20/40/50/60/80, NO, range 0-1000ppm (electrochemical)
6313719 IS sensor for OLCT 20/40/50/60/80, NO, range 0-100ppm (electrochemical)
6313720 IS sensor for OLCT 20/40/50/60/80, NO, range 0-300ppm (electrochemical)
6313721 IS sensor for OLCT 20/40/50/60/80, NO, range 0-1000ppm (electrochemical)

NO2 Nitrogen dioxide
6313722 IS sensor for OLCT 20/40/50/60/80, NO2, range 0-10ppm (electrochemical)
6313723 IS sensor for OLCT 20/40/50/60/80, NO2, range 0-30ppm (electrochemical)
6313877 IS sensor for OLCT 20/40/50/60/80, NO2, range 0-100ppm (electrochemical)

O2 Oxygen
6313710 XP sensor for OLCT 20/40/50/60/80, O2, range 0-30% Vol (2 year sensor lifetime) (electrochemical)
6313748 IS sensor for OLCT 20/40/50/60/80, O2, range 0-30% Vol (electrochemical)
6315C5A XP sensor for OLCT 20/40/50/60/80, O2, range 0-30% Vol (5 year sensor lifetime) (electrochemical)

O3 Ozone
6313735 IS sensor for OLCT 20/40/50/60/80, O3, range 0-1ppm (electrochemical)

PH3 Phosphine
6313737 IS sensor for OLCT 20/40/50/60/80, PH3, range 0-1ppm (electrochemical)

R1234yf
6314151 XP sensor for OLCT 20/40/50/60/80, HFO 1234yf 0-1000ppm (Semi-conductor)
6314225 XP sensor for OLCT 60 XPIR & OLCT 80 XPIR, range 0-100% LEL R1234YF (InfraRed)
6314226 XP sensor for OLCT 60 XPIR & OLCT 80 XPIR, range 0-2000ppm R1234YF (InfraRed)

R134a Freon R134A
6314227 XP sensor for OLCT 60 XPIR & OLCT 80 XPIR, range 0-2000ppm R134A (InfraRed)

R407f
6314228 XP sensor for OLCT 60 XPIR & OLCT 80 XPIR, range 0-2000ppm R407F (InfraRed)

R449a
6314233 XP sensor for OLCT 60 XPIR & OLCT 80 XPIR, range 0-2000ppm R449a (InfraRed)

SF6
6313986 XP sensor for OLCT 20/40/50/60/80, range 0-100% vol SF6 (Catharometric)
6314229 XP sensor for OLCT 60 XPIR & OLCT 80 XPIR, range 0-2000ppm SF6 (InfraRed)

SiH4
6313747 IS sensor for OLCT 20/40/50/60/80, SiH4, range 0-50ppm (electrochemical)

SO2 Sulfur dioxide
6313724 IS sensor for OLCT 20/40/50/60/80, SO2, range 0-10ppm (electrochemical)
6313725 IS sensor for OLCT 20/40/50/60/80, SO2, range 0-30ppm (electrochemical)
6313726 IS sensor for OLCT 20/40/50/60/80, SO2, range 0-100ppm (electrochemical)

VCM
6313926 IS sensor for OLCT 20/40/50/60/80, VCM, range 0-200ppm (OLCT60 avant 12/2018), operating temperature: 0°C to 40°C (electrochemical)
6314235 IS sensor for OLCT 20/40/50/60/80, VCM, range 0-200ppm (OLCT60 delivered after 12/2018) (electrochemical)

Enquire About This Product