Kidde AlarmLine II Analogue EN Cable AAE

Code: AAE-0500
  • Open and short circuit detection reduces the risk of false alarms
  • VdS EN54-22:2015/prA1:2007
  • Suitable for installation in hazardous areas

In StockMake An Enquiry

In a PVC outer sheath, an analogue linear heat detection cable supplied two lengths: AAE-0100 for 100 metres and AAE-0500 for 500m. Suitable for indoor applications where sensor cable is unlikely to be subjected to physical damage or exposed to harsh environmental conditions.

In temperature-sensitive environments, early detection of an abnormal change is crucial to protect life safety, critical processes and reduce losses. The AAE analogue range of linear heat detection cables uses exceptionally durable linear heat detection technologies that provide extensive and continuous coverage and are easy to install and fully integrate with building management systems. The products offer an enviable set of features bringing enhanced benefits and increased safety to the fire protection industry worldwide.aae-0100

  • Cable-based sensing allows detection at the point of risk.
  • Low installation and maintenance costs reduce the total cost of ownership.
  • Optional pre-alarm settings allow users to manage risk more effectively.
  • Approved to the latest standards.

Fast Response Time

This unique sensor cable and control method continuously respond to changes in temperature. The technology allows the facility to programme an early-warning pre-alarm as well as the specified alarm temperature. If the cable’s saturation reaches the pre-alarm point, the control unit triggers a warning, giving the user time to survey the at-risk area. Only when the temperature reaches the specified set alarm point will the control unit trigger a full alarm.

The Controller

The optional two-stage programmable alarm settings make the system and method of overheat detection incredibly flexible and ideal for use in various environments and applications. The technology automatically compensates for changes in ambient temperature to maintain alarm accuracy and offers up to 500 metres of continuous detection per control unit. The controller is compatible with any conventional or addressable fire alarm panel or other building management system.

Reset and Reuse

Analogue LHD cable is “self-restorable”, which means it is not always necessary to replace the cable after an incident. Once the alarm has been triggered and depending on the severity of the incident, the system can be reset with minimum disruption and inconvenience.

Order Information

AAE-0100 (100m) EN54-22 Analogue LHD Cable PVC
Alarmline II Analogue sensor cable for use with the AAECU EN54 control unit only
PVC-coated cable suitable for indoor use only
Operating temperature limits -40 to +125 Deg C, Continuous operating temperature -40 to +90 Deg C
Colour: Red, Cable diameter: 4.57 mm +/- 0.075mm
100m reel on a plastic bobbin, Dimensions (mm): 300 Dia x 100d, weight: 2.37Kg
AAE-0500 (500m) EN54-22 Analogue LHD Cable PVC
Alarmline II Analogue sensor cable for use with the AAECU EN54 control unit only
PVC-coated cable suitable for indoor use only
Operating temperature limits -40 to +125 Deg C, Continuous operating temperature -40 to +90 Deg C
Colour: Red, Cable diameter: 4.57 mm +/- 0.075mm
500m reel on a wooden bobbin, Dimensions (mm): 430 Dia x 140d, Weight: 11.85Kg

    Enquire About This Product


    Title Size
    aae-0100-brochure 86 KB
    aae-0500-brochure 79 KB

    Additional information

    Weight 0.09 kg