Kidde AlarmLine II Analogue EN Cable AAE

Code: AAE
  • Open and short circuit detection reduces the risk of false alarms
  • VdS EN54-22:2015/prA1:2007
  • Suitable for installation in hazardous areas

In StockMake An Enquiry

In a PVC outer sheath, an analogue linear heat detection cable supplied two lengths, AAE-0100 for 100 metres and AAE-0500 for 500m. Suitable for indoor applications where sensor cable is unlikely to be subjected to physical damage or exposed to harsh environmental conditions.

In temperature-sensitive environments, early detection of an abnormal change is crucial to protect life safety, critical processes and reduce losses. The AAE analogue range of linear heat detection cables uses exceptionally durable linear heat detection technologies that provide extensive and continuous coverage and are easy to install and fully integrate with building management systems. The products offer an enviable set of features bringing enhanced benefits and increased safety to the fire protection industry worldwide.aae-0100

  • Cable based sensing allows detection at the point of risk
  • Low installation and maintenance costs reduce the total cost of ownership
  • Optional pre-alarm setting allows the user to manage risk more effectively
  • Approved to the latest standards

Fast Response Time

This unique sensor cable and its method of control continuously respond to changes in temperature. The technology offers the facility to programme an early warning pre-alarm as well as the specified alarm temperature. If the cable’s temperature reaches the pre-alarm point, the control unit triggers a warning giving the user time to survey the area at risk. Only when the temperature reaches the specified set alarm point will the control unit trigger a full alarm.

The Controller

The optional two-stage programmable alarm settings make the system and method of overheat detection incredibly flexible and ideal for use in various environments and applications. The technology automatically compensates for changes in the ambient temperature to maintain the accuracy of alarm temperature and offer up to 500 metres of continuous detection per control unit. The controller is compatible with any conventional or addressable fire alarm panel or other building management system.

Reset and Reuse

Analogue LHD cable is “self-restorable”, which means it not always necessary to replace the cable after an incident. Once the alarm has been triggered and depending on the severity of the incident, the system can be reset with minimum disruption and inconvenience.

Order Information

AAE-0100 (100m) EN54-22 Analogue LHD Cable PVC
Alarmline II Analogue sensor cable for use with the AAECU EN54 control unit only
PVC coated cable suitable for indoor use only
Operating temperature limits -40 to +125 Deg C, Continuous operating temperature -40 to +90 Deg C
Colour Red, Cable diameter 4.57mm +/- 0.075mm
100m reel on a plastic bobbin, Dimensions (mm): 300 Dia x 100d, weight: 2.37Kg
AAE-0500 (500m) EN54-22 Analogue LHD Cable PVC
Alarmline II Analogue sensor cable for use with the AAECU EN54 control unit only
PVC coated cable suitable for indoor use only
Operating temperature limits -40 to +125 Deg C, Continuous operating temperature -40 to +90 Deg C
Colour Red, Cable diameter 4.57mm +/- 0.075mm
500m reel on a wooden bobbin, Dimensions (mm): 430 Dia x 140d, Weight: 11.85Kg

Enquire About This Product

Title Size
aae-0100-brochure 86 KB
aae-0500-brochure 79 KB

Additional information

Weight 0.09 kg