Honeywell Sensepoint & Zareba Sensors

Code: Sensepoint
  • Ideal for Industrial Applications
  • Affordable Fixed Gas Detection
  • Wide Range of Gas Sensors

In Stock
Make An Enquiry

Honeywell Sensepoint Flammable and Toxic Sensors are for fixed single point gas detection. The Flammable sensors provide a mV bridge output and read LEL or PPM. The Toxic versions measure ppm and Oxygen versions give percentage volume, both give a standard two wire 4-20mA loop output for use with Honeywell, Zellweger or third party controllers.

Zareba Sensepoint Flammable and Toxic Gas Sensors include Exd or Exe approved junction boxes, with three entries supporting metric and NPT use. Supplied pre wired with a hinged lid for making electrical connections. Suitable for use in hazardous areas.

The following gases can be detected: Flammable, Oxygen Hydrogen Sulphide, Carbon Monoxide, Chlorine, Ammonia, Hydrogen, Nitric Oxide, Nitrogen Dioxide and Sulfur Dioxide.

  • Life expectancy two to five years
  • Toxic detectors are pre calibrated for ease of installation
  • Front end Intrinsically safe design enable easy sensor swap out when powered
  • Zareba Sensepoint suitable for indoors or outside
  • Ingress Protection IP65, junction box versions IP66
  • Economical gas detection solution, no readings at point if used in isolation
  • Surecell electrochemical sensors & Sieger poison resistant catalytic bead
  • ATEX/IECEx Certified
  • Minimal expertise required
  • Range of accessories – Duct mounting, weatherproof cap, flow adaptor & collecting cone

A Sensepoint high temperature flammable sensor is available designed for high temperature hazardous environments, for example drying ovens or coating applications. The sensor alarm trips can be set as low as 5% LEL, spanning a wide temperature scale -55°C to +150°C. Concentration range can be user adjusted by a controller 0-20% LEL up to 0-100% LEL.

Enquire About This Product

Title Size
Sensepoint Brochure 1,006 KB
Sensepoint with Junction Box 826 KB
Sensepoint Toxic Sensor Operating Instructions 540 KB
Sensepoint LEL Combustible Sensor Operating InstructionsN 609 KB
Sensepoint HT Sensor 339 KB
Sensepoint HT Combustible Gas Sensor QuickStartGuideN 567 KB
_Sensepoint_Technical Handbook 959 KB
Sensepoint with Junction Box Manual 2 MB
SureCell_TechNote 391 KB
Product Notice_Catalytic Bridge To 4-20mA Converter End Of Life 94 KB
Industrial Fixed Product Guide 2018 3 MB

Additional information

Weight0.09 kg

Ordering Information

Sensepoint Toxic

2106B1400 H2S 0-20 ppm Toxic Sensor M20
2106B1401 H2S 0-50 ppm Toxic Sensor M20
2106B1402 H2S 0-100 ppm Toxic Sensor M20
2106B1500 H2S 0-20 ppm Toxic Sensor M25
2106B1501 H2S 0-50 ppm Toxic Sensor M25
2106B1502 H2S 0-100 ppm Toxic Sensor M25
2106B1700 H2S 0-20 ppm Toxic Sensor 3/4NPT
2106B1701 H2S 0-50 ppm Toxic Sensor 3/4NPT
2106B1702 H2S 0-100 ppm Toxic Sensor 3/4NPT
2106B1800 H2S 0-20 ppm Toxic Sensor 3/4NPT CSA
2106B1801 H2S 0-50 ppm Toxic Sensor 3/4NPT CSA
2106B1802 H2S 0-100 ppm Toxic Sensor 3/4NPT CSA
2106B1405 CO 0-100 ppm Toxic Sensor M20
2106B1406 CO 0-200 ppm Toxic Sensor M20
2106B1407 CO 0-500 ppm Toxic Sensor M20
2106B1505 CO 0-100 ppm Toxic Sensor M25
2106B1506 CO 0-200 ppm Toxic Sensor M25
2106B1507 CO 0-500 ppm Toxic Sensor M25
2106B1705 CO 0-100 ppm Toxic Sensor 3/4NPT
2106B1706 CO 0-200 ppm Toxic Sensor 3/4NPT
2106B1707 CO 0-500 ppm Toxic Sensor 3/4NPT
2106B1805 CO 0-100 ppm Toxic Sensor 3/4NPT CSA
2106B1806 CO 0-200 ppm Toxic Sensor 3/4NPT CSA
2106B1807 CO 0-500 ppm Toxic Sensor 3/4NPT CSA
2106B1410 Cl2 0-5 ppm Toxic Sensor M20
2106B1411 Cl2 0-15 ppm Toxic Sensor M20
2106B1510 Cl2 0-5 ppm Toxic Sensor M25
2106B1511 Cl2 0-15 ppm Toxic Sensor M25
2106B1711 Cl2 0-15 ppm Toxic Sensor 3/4NPT
2106B1810 Cl2 0-5 ppm Toxic Sensor 3/4NPT CSA
2106B1811 Cl2 0-15 ppm Toxic Sensor 3/4NPT CSA
2106B1413 NH3 0-50 ppm Toxic Sensor M20
2106B1414 NH3 0-1000 ppm Toxic Sensor M20
2106B1415 NH3 0-100 ppm Toxic Sensor M20
2106B1513 NH3 0-50 ppm Toxic Sensor M25
2106B1514 NH3 0-1000 ppm Toxic Sensor M25
2106B1515 NH3 0-100 ppm Toxic Sensor M25
2106B1713 NH3 0-50 ppm Toxic Sensor 3/4NPT
2106B1714 NH3 0-1000 ppm Toxic Sensor 3/4NPT
2106B1715 NH3 0-100 ppm Toxic Sensor 3/4NPT
2106B1813 NH3 0-50 ppm Toxic Sensor 3/4NPT CSA
2106B1814 NH3 0-1000 ppm Toxic Sensor 3/4NPT CSA
2106B1815 NH3 0-100 ppm Toxic Sensor 3/4NPT CSA
2106B1416 H2 0-1000 ppm Toxic Sensor M20
2106B1417 H2 0-10000 ppm Toxic Sensor M20
2106B1516 H2 0-1000 ppm Toxic Sensor M25
2106B1517 H2 0-10000 ppm Toxic Sensor M25
2106B1716 H2 0-1000 ppm Toxic Sensor 3/4NPT
2106B1717 H2 0-10000 ppm Toxic Sensor 3/4NPT
2106B1816 H2 0-1000 ppm Toxic Sensor 3/4NPT CSA
2106B1817 H2 0-10000ppm Toxic Sensor 3/4NPT CSA
2106B1418 NO 0-100 ppm Toxic Sensor M20
2106B1518 NO 0-100 ppm Toxic Sensor M25
2106B1718 NO 0-100 ppm Toxic Sensor 3/4NPT
2106B1818 NO 0-100 ppm Toxic Sensor 3/4NPT CSA
2106B1420 SO2 0-15 ppm Toxic Sensor M20
2106B1421 SO2 0-50 ppm Toxic Sensor M20
2106B1520 SO2 0-15 ppm Toxic Sensor M25
2106B1521 SO2 0-50 ppm Toxic Sensor M25
2106B1720 SO2 0-15 ppm Toxic Sensor 3/4NPT
2106B1721 SO2 0-50 ppm Toxic Sensor 3/4NPT
2106B1820 SO2 0-15 ppm Toxic Sensor 3/4NPT CSA
2106B1821 SO2 0-50 ppm Toxic Sensor 3/4NPT CSA
2106B1422 NO2 0-10 ppm Toxic Sensor M20
2106B1522 NO2 0-10 ppm Toxic Sensor M25
2106B1722 NO2 0-10 ppm Toxic Sensor 3/4NPT
2106B1822 NO2 0-10 ppm Toxic Sensor 3/4NPT CSA
2106B1430 O2 25% V/V Toxic Sensor M20
2106B1530 O2 25% V/V Toxic Sensor M25
2106B1730 O2 25% V/V Toxic Sensor 3/4NPT
2106B1830 0-25 V/V O2 Toxic Sensor 3/4NPT CSA

Sensepoint Flammable

2106B1200 0-100% LEL Flam. Sensor M20
2106B1201 0-100% LEL Flam. Sensor M25
2106B1202 0-100% LEL Flam. Sensor M26
2106B1203 Flammable M26 VQ1AB pellistor
2106B1204 0-100% LEL Flam. Sensor 3/4NPT
2106B1205 ppm Flam. Sensor M20*
2106B1206 ppm Flam. Sensor M25*
2106B1209 ppm Flam. Sensor 3/4NPT*

Sensepoint Flammable – High Temperature (150°C with 3rd party performance approval)

2106B2310 HT Flammable Sensor (ATEX) M20
2106B2311 HT Flammable Sensor (ATEX) M25
2106B2312 HT Flammable Sensor (ATEX) 3/4 NPT

Spares

2106B1545 O2 Electrochemical Cell Exchange Kit
2106B1546 SO2 Electrochemical Cell Exchange Kit
2106B1547 Cl2 Electrochemical Cell Exchange Kit
2106B1548 CO Electrochemical Cell Exchange Kit
2106B1549 H2S Electrochemical Cell Exchange Kit
2106B1594 NO Electrochemical Cell Exchange Kit
2106B1595 NH3 0-1000ppm Electrochemical Cell Exchange Kit
2106B1596 NH3 0-50ppm Electrochemical Cell Exchange Kit
2106B1597 H2 0-1000ppm Electrochemical Cell Exchange Kit
2106B1598 H2 0-10000ppm Electrochemical Exchange Kit
2106B1599 NO2 0-10ppm Electrochemical Exchange Kit

Accessories

00780-A-0100 Honeywell Junction Box Bartec DE1155 With Continuity Plate 1 x 25mm – 3 x 20mm Entries – ATEX Approved

00780-A-0160 Right Angle Mounting Bracket For Ceiling Mounting
02000-A-1635 Series 2000 Weather Housing Use With Toxic Sensor
02000-A-1640 Series 2000 Weather Housing use With Flammable Sensor
02000-A-1642 Series 2000 Collecting Cone Use With Flammable Sensor
02000-A-1645 Series 2000 Calibration Flow Housing Assembly (Flammable and Toxic)
02000-A-3120 Series 2000 Flow Housing Assembly Plastic
2106B1110 Catalytic Bridge To 4-20mA Converter

2106B2114 Toxic Calibration Kit including Calibration Cover, Removal Tool, Potentiometer Adjustment Tool

2106D2055 M36 / M40 Thread Adaptor
225-262-138 Cable Gland And Caps, 20mm, Nylon

90053-A-7001 1-way Sensepoint M20 Duct Mount Kit. Please order separately 00780-A-0100, 02000-A-1640 (for Combustible versions) or 02000-A-1635 (for Toxic versions)[Only For Sensepoint only sensors, not compatible with Zareba]

90053-A-7041 1-way Sensepoint M20 Duct Mount Kit ‘High Temp’. Please order separately 2052D0001 and 00780-A-0076[Only For Sensepoint only sensors, not compatible with Zareba]

90053-A-8002 1-way Sensepoint M25 Duct Mount Kit. Please order separately 00780-A-0100, 02000-A-1640 (for Combustible versions) or 02000-A-1635 (for Toxic versions)[Only For Sensepoint only sensors, not compatible with Zareba]

90068-A-8204 Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube Connector to Gas Bottle

90068-C-8291 PTFE Tubing 8mm O/D x 6mm I/D. Supplied per Meter

90068-C-8292 Soft PVC Tubing 8mm O/D x 5mm I/D. Supplied Per Meter 00910-A-0404 Hydrophobic barrier assembly for Weather Housing

Zareba Sensepoint (With Junction Box)

Each ATEX approved Sensepoint is supplied complete with pre-wired universal junction box (1 x threaded M20, 1x clearance 3/4″NPT,1 x clearance 1/2″NPT, 3 x approved stopping plugs, earth continuity plate), instruction manual and factory set gas sensor as listed below

SPSTAXF1 0-100%LEL Methane *1 *2
SPSTAXO1 0-25%v/v Oxygen *1 *2
SPSTAXC1 0-200ppm Carbon Monoxide *1
SPSTAXC2 0-500ppm Carbon Monoxide
SPSTAXH1 0-50ppm Hydrogen Sulphide *1
SPSTAXH2 0-20ppm Hydrogen Sulphide
SPSTAXH3 0-100ppm Hydrogen Sulphide
SPSTAXG1 0-1,000ppm Hydrogen *1
SPSTAXL1 0-5ppm Chlorine *1
SPSTAXL2 0-15ppm Chlorine
SPSTAXS1 0-15ppm Sulphur Dioxide *1
SPSTAXS2 0-50ppm Sulphur Dioxide
SPSTAXN1 0-10ppm Nitrogen Dioxide *1 *2
SPSTAXA1 0-50ppm Ammonia *1
SPSTAXA2 0-1000ppm Ammonia
*1 = Standard gas range to be used wherever possible.
*2 = Contact Norrscope for further information on alternate ranges.

Consumables (Spare Sensors)

SPSTAXF1SS 0-100%LEL Methane
SPSTAXO1SS 0-25%v/v Oxygen
SPSTAXC1SS 0-200ppm Carbon Monoxide
SPSTAXC2SS 0-500ppm Carbon Monoxide
SPSTAXH1SS 0-50ppm Hydrogen Sulphide
SPSTAXH2SS 0-20ppm Hydrogen Sulphide
SPSTAXH3SS 0-100ppm Hydrogen Sulphide
SPSTAXG1SS 0-1,000ppm Hydrogen
SPSTAXL1SS 0-5ppm Chlorine
SPSTAXL2SS 0-15ppm Chlorine
SPSTAXS1SS 0-15ppm Sulphur Dioxide
SPSTAXS2SS 0-50ppm Sulphur Dioxide
SPSTAXN1SS 0-10ppm Nitrogen Dioxide
SPSTAXA1SS 0-50ppm Ammonia
SPSTAXA2SS 0-1000ppm Ammonia

Accessories

02000-A-1645 Flow Housing Assembly (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)

00780-A-0160 Right Angle Mounting Bracket For Junction Box 00780-A-0100

02000-A-1635 Weatherproof cap for use with toxic detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)

02000-A-1640 Weatherproof cap for use with combustible detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000

02000-A-1642 Collecting cone for use with flammable detector (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)

90068-A-8204 Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube Connector to Gas Bottle

90068-C-8291 PTFE Tubing 8mm O/D x 6mm I/D. Per Meter
90068-C-8292 Soft PVC Tubing 8mm O/D x 5mm I/D. Per Meter

X4S-2006662 Field Device Tag Label (Based on Drawing Number 90084-C-7013).Material: 316 Stainless Steel (Supplied loose).Dimensions: 80x20x1.2mm. Please state the text per each tag required

94000-C-1001 2″ Pipe Mount Plate (please separately order 90083-A-8034)
90083-A-8034 2 x 2″ U-Bolts x M6 C/W Nuts and Washers 316SS for 2″ Pipe Mount Plate

Enquire About This Product