Drager Polytron TX
This product is now obsolete the equivalents to the Polytron TX are Polytron 5100 CLICK HERE
Polytron TX was a permanent gas monitor for the detection of toxic gases or O2. Zoned area approvals ATEX, UL and CSA.
For installation two mounting holes were incorporated into the Powder-coated aluminum transmitter housing.
Toxic gases and Oxygen are configured, user could choose ranges as below.
CO 0 to 100 / 300 / 500 ppm
H2S 0 to 20 / 50 / 100 ppm
O2 0 to 25 Vol%
Cl2 0 to 5 ppm *)
H2 0 to 500 ppm *)
NH3 0 to 100 / 300 / 500 ppm *)
NO2 0 to 20 ppm *)
SO2 0 to 20 ppm *)
Output to preventive devices or building management system or control room is provided by a 4-20mA signal. Fault signal indicated by 2mA or less. Maintenance 3, 4 or 5mA.
Electrcal supply 16 to 30 V DC, 2-wire
For commissioning and calibration tapping the magnet wand on the face will allow access to the calibration and menus of the detector externally.
Part Numbers
Polytron TX without sensor; UL, CSA, ATEX, suitable for CO, H2S, O2 4543405
Polytron TX without sensor; general purpose, suitable for Cl2, H2, NH3, NO2, SO2 4543435
Sensors
CO 6809605
H2S 6809610
O2 6809630
Cl2 6809665
H2 6809685
NH3 LC 6809680
NH3 HC 6809645
NO2 6809655
SO2 6809660
Magnetic wand for menu access 4543428