The Scott Spyglass system by Teledyne detects multiple combustible hydrocarbon gases simultaneously such as C1-C8 hydrocarbons (Methane, Ethane, Ethylene, Propane, Propylene, n-butane, Isobutane, 1, 3-butadiene, Isobutylene, Alkanes, Alkenes, Naphthenes, Benzenes).
It works by analysing the absorption of radiation caused by gases in the atmosphere and comparing it to background atmospheric absorption. Using two units, a Flash Source and Detector that can monitor a distance of up to 200 metres.
Spyglass Gas Detectors are robustly designed and can handle the toughest environments: circuit boards are epoxy coated for protection; MIL-C-810C testing for humidity, salt, fog, vibration, mechanical shock and temperature extremes; and SIL-2 approval per IEC61508 is a final statement in reliability.
The Spyglass system can replace twenty line of sight point gas detectors, saving up-front costs and ongoing maintenance costs. There are only two units to service, and the maintenance requirements are minimal. The only consumable is the Spyglass Xenon Flash Bulb.
Three colour LED gives a quick visual of unit status
Communications 4-20mA output, RS485 and HART
Intrinsically Safe communication port can be used with HART hand-held in non-safe areas for setup and diagnostics
Hydrocarbon Detection ATEX 2 GD (Ex de(ia) IIC T5). Supplied with tilt mount, without cable gland
SCO-8000481 Spyglass Model 20, distance 7 to 20 m, ATEX, M25, 4-20mA output, RS485 and HART,
SIL 2, c/w tilt mount
SCO-8000482 Spyglass Model 20, distance 7 to 20 m, ATEX, ¾ NPT, 4-20mA output, RS485 and
HART, SIL 2, c/w tilt mount
SCO-8000485 Spyglass Model 40, distance 15 to 40 m, ATEX, M25, 4-20mA output, RS485 and HART,
SIL 2, c/w tilt mount
SCO-8000486 Spyglass Model 40, distance 15 to 40 m, ATEX, ¾ NPT, 4-20mA output, RS485 and
HART, SIL 2, c/w tilt mount
SCO-8000489 Spyglass Model 100, distance 35 to 100 m, ATEX, M25, 4-20mA output, RS485 and
HART, SIL 2, c/w tilt mount
SCO-8000490 Spyglass Model 100, distance 35 to 100 m, ATEX, ¾ NPT, 4-20mA output, RS485 and
HART, SIL 2, c/w tilt mount
SCO-8000493 Spyglass Model 200, distance 80 to 200 m, ATEX, M25, 4-20mA output, RS485 and
HART, SIL 2, c/w tilt mount
SCO-8000494 Spyglass Model 200, distance 80 to 200 m, ATEX, ¾ NPT, 4-20mA output, RS485 and
HART, SIL 2, c/w tilt mount
Accessories
Bracket
SCO-8000447 Tilt Mount (Stainless steel)
SCO-8000448 Pole Mount (U-Bolt 5 inch)
Cable gland
6143564 Cable-gland XP 3/4 NPT for armoured cable, inner diameter 6 to 12 mm, external diameter 8,5 to 16 mm
6343490 Cable-gland kit, M25, stainless steel, for armoured cable
Installation
SCO-8000449 Commissioning Kit
Protection
SCO-8000455 Sunshade, Stainless Steel
Test
SCO-8000457 Function Check Filter Warning Level – Methane
SCO-8000497 Magnetic Mode Selector
Calibration
SCO-8000458 Function Check Filter Alarm Level – Methane
SCO-8000459 Function Check Filter Warning Level – Propane
SCO-8000460 Function Check Filter Alarm Level – Propane