Spectrex SharpEye 40/40D-LB UV/IR Flame Detector

Code: 40/40D-LB
  • Ultra-fast detection in 20 msec
  • Immunity to false alarms
  • UV & IR optical sensors

In StockMake An Enquiry

The SharpEye 40/40D-LB Ultra Fast UV/IR Flame Detector integrates ultraviolet and infrared optical sensors to detect fires from a wide variety of hazardous sources, such as hydrocarbon-based fuel and gas, hydroxyl, hydrogen, metal, and inorganic.

Features and Benefits

  • Superior detection range of hydrogen and hydrocarbon-based fuel and gas fires up to 92 ft (28 m).
  • Extended detection range more than doubles detection coverage
  • Ultra-fast detection, high-speed response under 50 msec
  • Unparalleled reliability – 150,000 hours MTBF
  • Best in class temperature range: -76 °F (-60 °C) to +185 °F (+85 °C)
  • Worldwide and regionally certified for hazardous areas
  • Performance and reliability approved by recognizable certification bodies
  • SIL3 compatible
  • Enhanced durability backed up with a five-year warranty
  • Smart field of view integrity test, allowing flawless operation
  • Innovative UV and IR built-in test – continuously validating the optical integrity and the electronic circuitry
  • Multiple output options for maximum compatibility with standard infrastructures
  • Plug and play – factory calibrated for immediate use in any fire detection system
  • Universal wiring option for a fast ordering process
  • Three sensitivity levels, adapting to any application
  • Two-mode heated optics for impeccable performance in challenging environmental conditions
  • Internal log event recorder to analyze past events

Applications

  • Oil and gas onshore and offshore installations and pipelines
  • Hydrogenation (petroleum refining, food processing, and chemical)
  • Chemical and petrochemical plants
  • Storage tank farms
  • Fuel and gas processing and storage facilities
  • Power generation
  • Explosives and munitions
  • Fertilizer plants
  • Automotive industry
  • Vehicle battery charging stations
  • Hydroxyl production and storage
  • Aerospace industry
  • Waste management facilities
  • Hydrogen fuel cell industry
  • Pharmaceutical industry
  • Printing
  • Hazardous materials storage areas
  • Food processing
  • Silane storage (pending)

Order Information

M25 / Aluminium:
40/40D-LB-6-31-AB-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-AB-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-31-AB-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AB-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-AB-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-31-AB-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AC-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-AC-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-31-AC-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AC-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-AC-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-31-AC-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AF-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-31-AF-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-31-AF-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AF-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-31-AF-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-31-AF-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AK-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-AK-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-AK-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AK-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-AK-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-AK-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AP-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-AP-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-AP-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AP-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-AP-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-AP-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AR-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-AR-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-AR-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-AR-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-AR-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-AR-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / With 40/40C,D tilt mount / With Stainless steel Protective cover
M25 / Stainless Steel :
40/40D-LB-6-31-SB-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-SB-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / Without 40/40C,D tilt mount / With SBS plastic Protective cover
40/40D-LB-6-31-SB-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SB-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-SB-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / With 40/40C,D tilt mount / With SBS plastic Protective cover
40/40D-LB-6-31-SB-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SC-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-SC-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-31-SC-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SC-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-SC-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-31-SC-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SF-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-31-SF-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-31-SF-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SF-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-31-SF-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-31-SF-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SK-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-SK-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-SK-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SK-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-SK-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-SK-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SP-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-SP-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-SP-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SP-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-SP-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-SP-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SR-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-SR-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-SR-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-31-SR-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-31-SR-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-31-SR-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / With 40/40C,D tilt mount / With Stainless steel Protective cover
3/4″ NPT / Aluminium:
40/40D-LB-6-32-AB-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-32-AB-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-32-AB-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AB-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-32-AB-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-32-AB-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AC-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-32-AC-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-32-AC-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AC-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-32-AC-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-32-AC-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AF-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-AF-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-32-AF-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AF-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-AF-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-32-AF-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AK-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / Without 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-AK-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / Without 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-AK-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AK-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / With 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-AK-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / With 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-AK-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AP-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-32-AP-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-AP-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AP-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-32-AP-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-AP-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AR-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / Without 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-AR-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / Without 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-AR-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-AR-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / With 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-AR-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / With 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-AR-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / With 40/40C, D tilt mount / With Stainless steel Protective cover
3/4″ NPT / Stainless Steel:
40/40D-LB-6-32-SB-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / Without 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-SB-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / Without 40/40C, D tilt mount / With SBS plastic Protective cover
40/40D-LB-6-32-SB-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-SB-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / With 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-SB-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / With 40/40C, D tilt mount / With SBS plastic Protective cover
40/40D-LB-6-32-SB-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-SC-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-32-SC-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-32-SC-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-SC-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover
40/40D-LB-6-32-SC-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-32-SC-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-SF-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-SF-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-32-SF-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-SF-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-SF-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-LB-6-32-SF-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / Stainless steel Protective cover
40/40D-LB-6-32-SK-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / Without 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-SK-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / Without 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-SK-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-SK-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / With 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-SK-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / With 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-SK-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / With 40/40C, D tilt mount / Stainless steel Protective cover
40/40D-LB-6-32-SP-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / Without 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-SP-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / Without 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-SP-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-SP-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / With 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-SP-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / With 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-SP-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-SR-N-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / Without 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-SR-N-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / Without 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-SR-N-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-LB-6-32-SR-Y-0 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / With 40/40C, D tilt mount / Without Protective cover
40/40D-LB-6-32-SR-Y-7 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / With 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-LB-6-32-SR-Y-8 SharpEye 40/40 UV/IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / With 40/40C, D tilt mount / Stainless steel Protective cover
Accessories
877090 40/40C, D tilt mount
789260-1 40/40C, D pole mount 3″
789260-2 40/40C, D pole mount 2″
789260-3 40/40C, D pole mount 4″
877670 40/40C, D duct mount
877163 40/40C, D protective cover – stainless steel
877263 40/40C, D protective cover – ABS plastic
877650 40/40C, D air shield
877563 40/40C, D Cone of view limiter
877060 40/40C, D Cone viewer (laser aimer excluded)
794079 USB/RS485 converter kit
888810 HART hand-held diagnostics kit

Enquire About This Product

Title Size
40/40D-LB Datasheet 394 KB

Additional information

Weight 0.09 kg

Specifications

Detection ranges
At highest sensitivity setting for 1 ft2 (0.1 m2) pan fire
Fuel Range (ft/m)
Gasoline 93/28
n-Heptane 93/28
Diesel 70/21
JP5 70/21
Kerosene 70/21
Ethanol 95% 57/17
Isopropyl alcohol (IPA) 70/21
Methanol 57/17
Methane(1) 60/18
Liquefied petroleum gas (LPG)(1) 60/18
Polypropylene pellets 60/18
Office paper 33/10
Hydrogen(1) 70/21
Magnesium alloy 33/10
Gun powder (1.5 in2 [10 cm2) 67/20
Fireworks (10 pieces per test) 10/3
Cooking oil 70/21
Mineral oil (20w50) 70/21
Wood 33/10
Ethylene glycol 23/7
Butyl acrylate 70/21
Vinyl acetate 70/21
Flammable adhesive (flash point < 140 °F [60 °C]) 70/21
Solvents 70/21
Oil paint 70/21
Jet fuel A1 70/21
Battery(2) 77/23
General specifications
Spectral response Ultraviolet: 0.185 to 0.260 μm
Infrared: 2.5 to 3.0 μm
Detection response time Standard response: Typically 5 sec at 93 ft (28 m)
Ultra fast response: 20 msec for flash fire pan fire from 10 ft
(3 m) distance via analog voltage output
High speed response (explosion): 50 msec for 1 ft (0.30 m)
diameter sphere LPG-air mixture explosion at 32.8 ft (10 m)
distance via analog voltage output
Sensitivity ranges 3 sensitivity ranges
Field of view Horizontal: 100 °
Vertical: 95 °
Coverage area 12,999 ft3 (3962 m3)
Temperature range Operating:-76 to +185 °F (-60 to +85 °C)
Storage: -76 to +185 °F (-60 to +85 °C)
Humidity Non-condensing relative humidity up to 100%
Electrical specifications
Operating voltage 24 Vdc nominal (18-32 Vdc)
Cable entries 2 x ¾-in. – 14 NPT conduits or 2 x M25 x 1.5 mm ISO
Electrical input protection According to EN 50130
Electromagnetic compatibility EMI/RFI protected to EN61000-6-3 and EN 50130
Electrical interface The detector includes 17 terminals and one wiring option
Outputs
Relays Alarm, fault, and auxiliary
SPST volt-free contacts rated 2A at 30 VDC
Analog voltage output default Analog port malfunction: 0 V (< 0.5 V)
Normal: 2 V ± 0.3 V
Alarm/explosion: 5 V ± 0.3 V
0-20 mA (stepped) default(1) Fault: 0 ± 1 mA
Built-in test (BIT) fault: 2 mA ± 0.3 mA
Normal: 4 mA ± 0.3 mA
Warning: 16 mA ± 0.3 mA
Alarm: 20 mA ± 0.3 mA
HART® protocol HART communication on the 0-20 mA analog current (FSK) used for maintenance, configuration changes, and asset management, available in mA source output wiring options
RS-485 RS-485 Modbus®-compatible communication link that can be used in computer controlled installations
Mechanical specifications
Enclosure options Electropolished stainless steel 316
Heavy duty copper free aluminum (less than 1%), polyurethane painted
Tilt mount Electropolished stainless steel 316
Dimensions Detector: 4 x 4.6 x 6.18 in (100.6 x 117 x 155 mm)
Weight Detector stainless steel: 6.3 lb (2.9 kg)
Detector aluminum: 2.8 lb (1.3 kg)
Tilt mount: 2.5 lb (1.1 kg)
Environmental standards DNV 2-4
Water and dust IP66 and IP68 per EN 60529
NEMA® 250 6P

Enquire About This Product