The Micronics Ultraflo U1000MKII-HM is a Clamp-on, non-invasive Ultrasonic heat meter providing an alternative to a traditional in-line meter installation, plus dry servicing, providing minimum downtime and maximum availability. Suitable for energy management and billing applications in domestic and commercial, district or shared heating or cooling systems. Offering low installation cost and maintenance benefits.
Features
- Electronic transmitter – LCD with backlight – install & service information
- Includes adjustable transducer guide rail and all mounting hardware
- Optional Modbus RTU slave, RS485 serial and M-Bus communication. Modbus connection cable is 1 m
- Cross-correlation flow measurement system
- 1Mhz transducers to get through poor/old thick wall pipes and larger pipework
- Water/Glycol option
- Simple to install: connect power and enter the pipe inside diameter, adjust the sensors and clamp on the pipe; no specialist skills or tools are required
- Integrated pulse output – aM&T & BEM’s compatible with Modbus
Technical Specification
- Heat Meter Standard: The Heat/Energy calculation is designed to comply with EN1434 section 6
- Turn Down Ratio: 200:01
- Accuracy: +/-1-3% of flow reading for >0.3 m/s (1 ft/s)
- Flow Velocity Range: 0.1 m/s – 10 m/s (0.3 ft/s – 32 ft/s)
- Pipe Range: Available in 2 options, 22 mm – 115 mm and 125 mm – 180 mm (6″) OD. Note pipe size is dependent on pipe material and internal diameter.
- Pipe Material: Steel, Stainless Steel, Plastic and Copper
- Water Temp Range: 0°C – 85°C (32°F – 185°F)
- Temperature sensors: Clamp-on PT100 Class B 4 wire (pair), range 0°C – 85°C (32°F – 185°F) , resolution 0.1°C (0.1 °F). Minimum delta T 0.3°C
- Outputs – pulse or frequency for volume flow, energy and alarms
- External Power Supply: 12V-24V +/- 10% AC/DC at 7 watts per unit. Optional plug-in 12 V power supply
- Enclosure rating IP 54
- Input/Output Cable: 5 m x 6 core for power in and pulse out
- Dimensions: 250mm x 48mm x 90mm (10″x 2″x 4″) (electronics + guide rail)
Order Information
Part Number | Model | Pipe Sizes [mm OD] | Temp. Range |
[mm ID] | |||
804-20001400 | U1000MKII-HM Pulse Only, up to 4” pipe | 22-115 OD | -0°C to +85°C |
(20-110 ID) | |||
804-20004600 | U1000MKII-HM Pulse Only, up to 6” pipe | 125-180 OD | -0°C to +85°C |
(105-165 ID) | |||
804-20001402 | U1000MKII-HM with Pulse & Modbus, up to 4” pipe | 22-115 OD | -0°C to +85°C |
(20-110 ID) | |||
804-20004602 | U1000MKII-HM with Pulse & Modbus, up to 6” pipe | 125-180 OD | -0°C to +85°C |
(105-165 ID) | |||
804-20001403 | U1000MKII-HM with Pulse & M-bus, up to 4” pipe | 22-115 OD | -0°C to +85°C |
(20-110 ID) | |||
804-20004603 | U1000MKII-HM with Pulse & M-bus, up to 6” pipe | 125-180 OD | -0°C to +85°C |
(105-165 ID) |