Micronics Portaflow D650 Non-Contacting Doppler Flow Meter

Code: 1000-1023
  • Rugged IP67 extruded aluminium enclosure
  • Cost-effective metering
  • Portable non-contact flow measurement for harsh mediums & environments

In StockMake An Enquiry

The Portaflow D650 ultrasonic sensor injects high-frequency sound through the pipe wall into the flowing liquid. Gas bubbles or solids suspended in the liquid reflect the ultrasonic signal to the sensor. When sound is reflected from moving bubbles or particles, it is returned to the sensor at a shifted frequency, called the Doppler effect.

The PF D650 continuously measures the change from its transmitted frequency to the received frequency to measure flow accurately.

Fast & Easy Flow Measurement of Challenging Mediums from Outside The Pipe

Features

  • Advanced signal processing
  • Low power mode to extend battery life
  • Suitable for fluids containing suspended solids or bubbles (minimum size of 100 microns, minimum concentration 75 ppm)
  • Stainless steel mounting kit and carry case
  • Simple to install and operate
  • Built-in 12 million point data logger

Applications

  • Sewage
  • Treated Wastewater
  • Aerated Water
  • Sludge and Slurries
  • Chemicals and Solvents
  • Viscous Liquids
  • Abrasives
  • Food Products
  • Pulp Stock
  • Acids and Caustics

Includes

  • PSE4-A2 sensor – clamp-on, single head ultrasonic for 12.5mm – 4.5m ID pipes or larger
  • Sensor cable – 3.5m shielded coaxial pair with connector
  • PC4 sensor mounting kit with SuperLube coupling compound and stainless steel clamps for pipes up to 32” (80cm)
  • Electronics – IP67 portable extruded aluminium with protective silicone caps
  • Flow rate range – ± 0.1 to 40 ft/sec (± 0.03 to 12.2 m/sec) in most applications
  • Accuracy – ±2.0% of reading or ±0.1 ft/sec (±0.03 m/s), whichever is greater
  • Carry Case – I IP67 with protective moulded foam inserts for all transducer combinations
  • Display – Colour TFT LCD, IPS type, 2.8” screen size, 320×240, 500 NITS Brightness
  • Power – Rechargeable Lithium polymer battery with up to 15 hours of continuous operation
  • Datalogger – 12 million data point capacity
  • Extended Logging – Deploy in the low-power state to significantly increase battery life when log interval configured for 30s to 1hr
  • Calibration – Wet calibrated at factory. Built-in 5-key configuration
  • CE

Enquire About This Product

Title Size
Datasheet 379 KB

Additional information

Weight 0.09 kg

Specifications

GENERAL SPECIFICATIONS
Operating Parameters: Liquids containing suspended solids or bubbles with a minimum size of 100 microns and minimum concentration of 75 ppm
Flow Rate Range: ±0.03 m/s to 12.2 m/s (±0.1 ft/s to 40 ft/s) in most applications
Pipe Size: Ultrasonic sensor mounts on any pipe from 12.7 mm to 4.6 m ID (0.5 into 15 ft)
Display: Colour TFT LCD, IPS type, 2.8” screen size, 320 x 240 resolution, 500 NITS brightness, super wide view
Power Input: Built-in rechargeable lithium polymer battery for up to 15 hours continuous operation
External mains to USB-C charger with 100-240V AC, 50-60Hz, 0.6A input; and 5.0V DC, 3A, 15W output
Outputs: Log files, daily log files, parameter settings files, and waveform capture files via USB-C flash drive (included)
Data Logger: 12 million point capacity, configurable for velocity or flow rate, date and time stamped, configurable format for Logger Software (LG2) or CSV, available intervals of 10 s, 30 s, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min, and 1 hr
Extended Logging: Can be deployed in sleep-logging mode for extended battery duration.
PC Software: Free Logger Software for Windows. For display, manipulation, analysis, and exporting of data.
Operating Temp. (Electronics): -20 °C to +60 °C (-5 °F to +140 °F)
Electronics Enclosure: IP67 when transducer cables are connected. IP65 when transducer cables are not connected. Aluminium enclosure with silicone protective end covers.
Carry Case: IP67, with protective moulded foam with room for transducer and installation hardware
Accuracy: ±2% of reading or 0.03 m/s (0.1 ft/s), whichever is greater. Requires solids or bubbles with a minimum size of 100 microns and a minimum concentration of 75 ppm. Repeatability: ±0.1%, Linearity ±0.5%
Configuration: Built-in 5-button keypad interface with English, French, and Spanish menu language selection.
Optional user-configured password protection.
Approvals: CE
TRANSDUCER SPECIFICATIONS
Standard Model PSE4-A2: Clamp-on, single-head ultrasonic for pipes from 12.7 mm to 4.6 m ID (0.5 into 15 ft) with 3.4 m (12 ft) shielded dual-coaxial cable and latching connector
Sensor Mounting Kit: Stainless steel pipe clamp and 3.0 fl oz coupling compound
Pipe Materials: Steel, stainless steel, cast iron, ductile iron, concrete-lined ductile iron, PVC, HDPE, or any contiguous pipe material that conducts sound, including lined pipes with a liner bonded to the pipe wall. Avoid pipes with loose insertion liners and air-containing pipe walls.
Operating Temperature: -40 °C to +150 °C (-40 °F to +300 °F)
Ingress Protection IP68, can withstand 10psi (approx. 23 ft or 7 m of H2O) for 24 hours
POPULAR OPTIONS
Sensor Cable: 15.2 m (50 ft) sensor cable extension, shielded, with connectors
Sensor Mounting: Extra silicone coupling compound. Additional stainless steel pipe clamps

Enquire About This Product