Micronics Portaflow D550 Non-Contacting Doppler Flow Meter

Code: 1000-1012
  • Displays, data logs, transmits & totalises flow in closed pipes
  • Versatile, easy to use
  • Ideal for problem liquids

In StockMake An Enquiry

Portable Flow Meter for Dirty or Aerated Liquids. Troubleshoot Flow from Outside a Pipe

The PF D550 Portable Doppler Flow Meter can monitor and balance flow or troubleshoot flow problems in full pipes. It is ideal to evaluate the performance of in-line flow meters and can be installed, calibrated and started up in minutes. Use it for projects where a permanent flowmeter is not required or to replace installed flow transmitters temporarily.

The PF D550 ultrasonic sensor is clamped on the outside of a pipe. An acoustic pulse is reflected back to the sensor from particles or gases in the flowing liquid. The flow rate of any fluid can be measured as long as it contains air bubbles or solids.

It is ideal for wastewater, slurries, sludge and most chemicals, acids, caustics and lubrication fluids. With its internal battery, the PF D550 can be operated all day and then recharged overnight. It can be powered by a supplied 110-240VAC wall plug adapter for continuous use.

Features

  • Fast, Easy Flow Measurement with Non-Contacting Ultrasonic Sensor (PSE4 – strap-on, single head ultrasonic for 0.5” – 180” (12.5 mm to 4.5 m) ID pipes or larger).
  • Sensor cable – 12 ft / 3.5 m shielded coaxial pair.
  • Simple 5-key Calibration.
  • 300,000 Point Data Logger.
  • 4-20mA Output.
  • 10-Digit Totaliser.
  • AC/DC Operation.
  • Built-in Rechargeable Battery.
  • 1 set of cables – 4-20mA and USB.
  • Manual – Installation and Operation.

Enquire About This Product

Title Size
D550 Datasheet 3 MB

Additional information

Weight 0.09 kg

Specifications

General Specifications
Flow Rate Range: ± 0.03 to 12.2 m/sec (±0.1 to 40 ft/sec) in most applications
Pipe Size: Ultrasonic sensor mounts on any pipe from 12.5 mm to 4.5 m (½” to 180” ID)
Display: White, backlit matrix – displays flow rate, totalizer, operating mode and calibration menu
Power Input: Built-in NiMH battery for up to 18 hours continuous operation
External charger with 100-240VAC 50/60Hz input
Outputs: 4-20mA (500 ohm) when AC powered
USB for Data Log transfer by direct PC connection
Data Logger: Programmable 300,000 data point capacity, time and date stamped or formatted reports including total, average, minimum, maximum and times of occurrence
PC Software: ‘Logger’ for Windows Vista or higher. Retrieves, displays and saves data log files
Electronics Operating Temperature: -23° to 60°C (-10° to 140°F )
Electronics Enclosure: Portable, ABS enclosure
Carry Case: Rated IP67 with protective molded foam insert
Accuracy: ±2% of reading or 0.03 m/sec (0.1 ft/sec). Requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability: ±0.1%, Linearity: ±0.5%
Calibration: Built-in 5-key programming with user-friendly calibration menu, password protected
Language Selection: English, French, Spanish
Sensitivity: Adjustable cut-off, Damping: adjustable
Approvals: Charger is CE and UL approved. The PF D550 is not certified for use in hazardous rated locations
Sensor Specifications
Standard Model PSE4: Clamp-on, single-head ultrasonic for pipes from 12.5 mm to 4.5 m (½” to 180” ID) with 3.4 m (12 ft) shielded dual-coaxial cable
Sensor Mounting Kit: Stainless steel pipe clamp and 150 g (5.3 oz.) silicone coupling compound
Operating Temperature: -40° to 150°C (-40° to 300°F)
Options
Sensor Cable: 15 m (50 ft) sensor cable extension, shielded, with connectors
Sensor Mounting: PC4 Sensor mounting kit with CC30 coupling compound and stainless steel clamps for pipes up to 32” (80 cm)