Micronics DLT 2.0 Differential Level Transmitter

Code: 1000-1015
  • Simple solution for barscreen level control
  • Two non-contacting ultrasonic sensors
  • Large white backlit LCD display

In StockMake An Enquiry

The DLT 2.0 Differential Level Transmitter is a simple solution for differential level measurement that includes applications found in wastewater treatment plants, pump stations, and combined sewer systems. The Differential Level Transmitter includes two differential level sensors. Position each sensor at your desired location, above a channel, up and downstream from a bar screen, for example, and the DLT 2.0 can display and transmit differential level measurement. The downstream sensor could be positioned above a flume or weir to measure and totalize open channel flow.

To make the most out of your DLT 2.0, install one sensor on each side of a mechanical bar screen to continuously monitor the level. The built-in relays or 4- 20mA outputs automatically activate the bar screen rake at pre-set levels. Three 4-20mA outputs are configured to transmit upstream level, downstream level (or flow), and differential level. The built-in relays of the Differential Level Transmitter can be calibrated for level control, differential level control, or open channel flow.

Other applications for the DLT 2.0 include two-tank inventory, where you can monitor levels within two tanks with just one instrument, aiding stock control and process efficiency. The Differential Level Transmitter will alternate a level display in both tanks and transmit 4- 20mA outputs.

Features & Benefits

  • Measures Level, Differential Level, and Open Channel Flow
  • Three isolated 4- 20mA outputs
  • Built-in 5-key calibration
  • 2 programmable control relays
  • Optional 2 million point data logger
  • Optional intrinsically safe sensors
  • Brand: Greyline

    Enquire About This Product


    Title Size
    DLT 2.0 Datasheet 334 KB

    Additional information

    Weight 0.09 kg

    Specifications

    GENERAL SPECIFICATIONS
    Electronics Enclosure: NEMA4X (IP66) polycarbonate with clear, shatterproof cover
    Accuracy: ±0.25% of Range or 2 mm (0.08 in) whichever is greater
    Repeatability and Linearity: ±0.1%
    Display: White, backlit matrix – displays upstream, downstream, and differential level, open channel flow and totalizer, relay states, operating mode, and calibration menu
    Programming: Built-in 5-key calibrator with English, French, or Spanish language selection
    Power Input: 100-240 V AC 50/60 Hz (see Options), 3 W maximum (with standard features)
    Analog Output: Three Isolated 4-20mA (upstream and downstream level (or open channel flow) and differential level, 1 kΩ load maximum.
    Control Relays: Qty 2, rated 5 A SPDT, programmable for level control, differential control, or flow proportional pulse
    Operating Temp. (Electronics): -20 °C to +60 °C (-5 °F to +140 °F)
    Approximate Shipping Weight: 6.8 kg (15 lb)
    TRANSDUCER SPECIFICATIONS
    Standard Sensor: Includes two PZ15 ultrasonic sensor
    Maximum Range: 4.6 m (15 ft) with standard PZ15 sensor
    Deadband (Blanking): Programmable, Minimum 203.2 mm (8 in)
    Beam Angle:
    Operating Frequency: 92 kHz
    Exposed Materials: PVC
    Operating Temperature: -40 °C to 65 °C (-40 °F to 150°F)
    Temperature Compensation: Temperature probe inside the level sensor for high accuracy in changing temperatures
    Sensor Cable: RG62AU coaxial, 7.6 m (25 ft) standard length (See Options)
    POPULAR OPTIONS
    Sensors: 9.7 m (32 ft) measurement range / Intrinsically Safe models
    Sensor Cable: 15.2 m (50 ft) or 30.5 m (100 ft) RG62AU coaxial continuous from the sensor, or splice up to 152.4 m (500 ft) with optional JB Watertight NEMA4 steel with connection terminal strip
    Power Input: 9-32 V DC
    Extra Control Relays: 4 additional (6 total) rated 5 A SPDT
    Data Logger: 2 million point logger with USB output and Windows software – 3 channel logging (A & B sensors plus Differential or Open Channel flow)
    Enclosure Heater: Thermostatically controlled – recommended for temperatures below 0 °C (32 °F)
    Intrinsic Safety Barriers: For Sensor mounting in Class I, II, III, Div. 1, 2, Groups C, D, E, F, G hazardous locations
    Sensor Mounting Stand: Adjustable, includes galvanized steel pipe, flanges, fittings, and hardware
    Sunscreens: Sensor sunscreen and enclosure sunscreen for outdoor installations

      Enquire About This Product