Honeywell BW RigRat Multi-Gas Area Monitor

  • Transportable
  • Pumped or Diffusion versions
  • One-button operation

In StockMake An Enquiry

The Honeywell BW RigRat is easy to use, just position the monitor near to workers, and it will alert them of gas hazards in their proximity, suitable for deployment indoors and outside.

  • Up to 8 weeks of runtime on a single charge. Longer runtime than any area monitor in its class.
  • Up to six slots for interchangeable gas sensors. Choice of electrochemical, PID, infrared, and catalytic bead sensors (measuring percent LEL and percent by volume).
  • Integrated Noise sensor and Metrological data sensors.
  • Enhanced configurations with programmable input and output.
  • Approval for explosive atmosphere. Certified for ATEX/IECEx Zone 0 and CSA C1D1.
  • Flexible applications. Zone declassification, turnarounds, confined space, routine maintenance, fence line and more. Available with pump for remote sampling.
  • Simple setup with a smartphone. Easy mobile app for alarm set points, calibration records and more.
  • Added protection. Alerts workers to nearby gas leaks, whereas personal detectors cover only the breathing zone.

Features & Benefits

  • Position several BW RigRat monitors to form a wireless safety perimeter.
  • Use Honeywell’s remote monitoring software to see gas readings, location and other data from any device with an internet connection — for fast, informed decisions. Add an optional noise sensor or meteorological sensor.
  • Compatible with Honeywell’s Touchpoint Plus controller for visibility on BW RigRat monitors & workers’ personal detectors.
  • Line power for extended runtime in the field.
  • I/O ports providing additional input capabilities and local executive activation.
  • Inert mode that prevents alarm in normal ambient air.
  • Large, easy-to-read display.
  • Rugged, weatherproof design, with an optional protective cage.
  • Operating temperatures from -40 to +140°F (-40 to +60°C).

Enquire About This Product

Title Size
Honeywell BW RigRat Datasheet 89 KB
Honeywell-bw-rigrat-cage-kit-installation-guide 3 MB
Honeywell bw-rigrat-quickstart-guide 582 KB
Honeywell-bw-rigrat-wireless-solutions 1,010 KB
Honeywell-bw-rig-rat-manual 2 MB

Additional information

Weight0.09 kg

Ordering Information

Monitor-Only Configuration Includes:

  • BW RigRat monitor with sensors, battery and wireless options as specified, and filter(s) installed
  • Power Adapter (W03-3044-000)
  • LCD cover (W03-2129-000)
  • Diffusion calibration cap assembly (W03-3013-000)
  • Pump calibration tube assembly (W03-3020-000)
  • External Filter (Pumped version only) (W03-3006-000)
  • Antenna 868-928MHz, RP-N (550-7056-000)
  • Antenna 2.4GHz, RP-N (550-7057-000)
  • Quick Start Guide (W03-4002-000)
  • Calibration and test certificate
  • Warranty / registration card

Instruments (other configurations available, please enquire)

HRR-A100009ABK-000
BW RigRat, Basic diffusion: BLE only (BLE default for all versions), Catalytic LEL (0-100% LEL), CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30% Vol.)

HRR-B100009ABK-000
BW RigRat, Basic pump: BLE only (BLE default for all versions), Catalytic LEL (0-100% LEL), CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30% Vol.)

HRR-A100100ABK-000
BW RigRat, Basic diffusion: BLE only (BLE default for all versions), Ex NDIR (0-100% LEL) Low Power, CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30% Vol.)

HRR-B100100ABK-000
BW RigRat, Basic pump: BLE only (BLE default for all versions), Ex NDIR (0-100% LEL) Low Power, CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30% Vol.)

HRR-C102009ABK-000
BW RigRat, Enhanced diffusion: Input/output + wireless, BLE, Mesh 868MHz (Portables Systems), Catalytic LEL (0-100% LEL), CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30%Vol.)

HRR-C102100ABK-100
BW RigRat, Enhanced diffusion: Input/output + wireless, BLE, Mesh 868MHz (Portables Systems), Ex NDIR (0-100% LEL) Low Power, CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30% Vol.), GPS

HRR-C103100ABK-000
BW RigRat, Enhanced diffusion: Input/output + wireless, BLE, Mesh 2.4GHz (MeshGuard System), Ex NDIR (0-100% LEL) Low Power, CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30% Vol.)

HRR-D102009ABK-000
BW RigRat, Enhanced Pump: Input/output + wireless, BLE, Mesh 868MHz (Portables Systems), Catalytic LEL (0-
100% LEL), CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30%Vol.)

HRR-G102009ABK-000
BW RigRat, Enhanced diffusion: Input/output + wireless + Noise Sensor, BLE, Mesh 868MHz (Portables Systems),Catalytic LEL (0-100% LEL), CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30% Vol.)

HRR-H102009ABK-000
BW RigRat, Enhanced pump: Input/output + wireless + Noise Sensor, BLE, Mesh 868MHz (Portables Systems), Catalytic LEL (0-100% LEL), CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30% Vol.)

HRR-G102100ABK-100
BW RigRat, Enhanced diffusion: Input/output + wireless + Noise Sensor, BLE, Mesh 868MHz (Portables Systems), Ex NDIR (0-100% LEL) Low Power, CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ -Liquid Oxygen (0-30% Vol.), GPS

HRR-H102100ABK-100
BW RigRat, Enhanced pump: Input/output + wireless + Noise Sensor, BLE, Mesh 868MHz (Portables Systems), Ex NDIR (0-100% LEL) Low Power, CO – Carbon Monoxide (0-500 ppm), H₂S – Hydrogen Sulphide (0-100 ppm), O₂ – Liquid Oxygen (0-30% Vol.), GPS

Accessories and Replacement Parts

400-4083-000 Dust Cap I/O Connector
400-4105-003 Connector Plug MALE 3POS Solder
400-4105-010 Connector Plug MALE 10POS Solder
400-4105-014 Connector Plug MALE 14POS Solder
550-7056-000 BW RigRat Antenna 868-928MHz, RP-N
550-7057-000 BW RigRat Antenna 2.4GHz, RP-N
F08-2119-000 Alarm Bar Stand Controller Cabinet
M01-2029-000 Sensor Under Foam BW RigRat
M01-2067-000 Waterproof Membrane
W03-2009-000 Rubber-Gas IN and OUT BW RigRat
W03-2038-000 Rain Cover
W03-2111-000 RigRat Top Handle
W03-2129-000 LCD Protection Cover
W03-2154-000 RAEMet Cable
W03-2200-000 RAEMet Metal Bracket
W03-2203-000 Storage Rack kit
W03-3006-000 Gas Inlet Connector (pump version only)
W03-3018-000 IS barrier kit
W03-3037-000 Base Assembly
W03-3042-000 Metal cage kit for BW RigRat
W03-3044-000 AC/DC adaptor, 110~240VAC input, 6V 3A output
W03-3045-000 BW RIgRat RAEMet kit
W03-4002-000 Quick start guide (QSG) BW RigRat
W03-2140-000 Noise Sensor Cover for BW RigRat
W03-2084-000 Noise Sensor Foam for BW RigRat
W03-3013-000 Diffusion calibration cap Assembly
W03-3020-000 Pump calibration tube Assembly
W03-3015-000 Gas Cover Assembly (BW RigRat Diffusion)
W03-3005-000 Gas Cover Assembly (BW RigRat Pumped)
W03-3043-000 Clamp Kit for BW RigRat (include 2 clamps and 4 screws)
W03-3016-000 Pump Assembly for BW RigRat

Spare Sensors

C03-0992-100 Ex NDIR (0-100% LEL) LP
C03-0992-000 Ex NDIR (0-100% VOL) LP
C03-0990-100 Ex NDIR (0-100% LEL) SIL l
C03-0990-000 Ex NDIR (0-100% VOL) SIL l
C03-0991-000 CO₂ NDIR (up to 50,000 ppm)
C03-0912-000 4R+ PID(10.6eV)
C03-0906-000 4R+ CO Sensor Module
C03-0907-001 4R+ H₂S Sensor Module
C03-0904-000 4R+ H₂S High Range Sensor Module
C03-0973-100 4R+ SO₂ Sensor Module
C03-0974-000 4R+ NO Sensor Module
C03-0975-000 4R+ NO₂ Sensor Module
C03-0949-000 4R+ HCN Sensor Module
C03-0950-000 4R+ NH₃ Sensor Module
C03-0978-000 4R+ Cl₂ Sensor Module
C03-0908-001 4R+ O₂ Sensor Module
C03-0903-000 4R+ CO High Range Sensor Module
C03-0979-000 4R+ CO (H₂ Compensated) Sensor Module
C03-0801-000 Sensor Module (Analog) LEL 4R+

Enquire About This Product