| General |
|
| Weight |
3 lbs (approx.) |
| Carry case dimensions |
21” x 17.5” x 9.5” |
| Display |
3.5” color LCD |
| Storage |
Internal SD card (not removable) |
| Power |
|
| Battery |
Removable |
|
Rechargeable |
|
Lithium-ion pack, 10.8 VDC 2.6Ah |
| Battery Run Time |
8 hours at 32°F (approx.) |
| Battery Charger |
External |
|
110-240 VAC, 50/60 Hz Universal |
| Charge Time |
2-3 hours full charge (approx.) |
| Charging Indicator |
Integrated into Dual Battery Charger |
| Detection/Measurement System |
|
| Detection Method |
Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Detection Distance |
100 ft (30m) nominal – may vary due to background type and conditions |
| Measurement Range |
0 to 50K PPM-M |
| Sensitivity |
5 PPM-M at distances from 0 to 100 ft (30m) |
| Beam Size |
Conical in shape with a 22” diameter at 100 ft (55cm at 30m) |
| Lasers |
|
| IR Laser |
Class I |
| Spotter Laser |
On time duration is 2 minutes |
|
Class 2(II)<2mW @532nm |
|
Spot Size is 7mm at 15M |
| Eye Safety Warning |
Do not stare into beam or view directly with optical instrument |
| Display |
|
| Resolution |
320×240 |
| Camera |
|
| Color |
|
| Aperture |
f/2.6 |
| FOV |
94DEG (at6.0mm image circle) |
| GPS |
|
| Compatible with |
GPS / GLONASS / Beidou / Galileo |
| Communication |
|
| Bluetooth 4.2 BLE (to support future features and mobile applications) |
|
| Wi-Fi |
|
| USB Dual Mode |
|
| Alarms |
|
| Digital Methane Detection (DMD) |
Audible tone and visible color border when detection threshold exceeded |
| Adjustable Detection Alarm Level |
|
| 50’ |
1 to 200 PPM-M |
| 100’ |
1 to 400 PPM-M |
| System Fault & Warnings |
Audible alarm and visual indication on the display |
| Testing |
|
| Built-In Self-Test |
Verifies operation and adjusts laser wavelength for maximum sensitivity |
| Test Gas Cell |
Integrated within carrying case |
| Datalogging |
|
| Saves to Internal Memory |
FAULT logs |
|
Self-Test logs |
|
Captures |
| Data Collected |
Includes but not limited to: |
|
CH4 PPM-M measurement |
|
GPS location |
|
Timestamp |
|
Battery level |
|
Battery voltage |
|
Serial number of the instrument |
| Operating Conditions |
|
| Operating Temperature |
0° to +122°F (-17° to 50°C) |
| Humidity |
5 to 95% RH, non-condensing |
| Regulatory |
|
| Instrument Protection |
IP54 (water splash and dust resistant) |
| Compliance |
EMC (EN61000-6-2, EN6100-6-4) |
| Radio Equipment Directive |
(2014/53/EU) ETSI EN 301 489-1 v2.2.0 |
| EN 61326-1:2013 |
|
| 47 CFR Part 15 & ICES-003 |
|