Geotech G100 CO2 Incubator Analyser

Code: G100
  • Accurate CO2 readings
  • Quick verification of CO2 incubator levels
  • Time saving with dual temperature probes

In StockMake An Enquiry

The G100 CO2 analyser is specifically designed to monitor CO2 for the verification of incubators in research and pharmaceutical markets. This unit has been developed to incorporate the latest technology and specification requirements, which provide the user with a fast, simple-to-use and accurate piece of laboratory kit.

Features

  • CO2 0 – 20%
  • Options for:
    • O2 0-100%
    • Dual temperature probes 0 to 50°C
    • Data storage and download
    • Humidity sensor 0-100%

Benefits

  • Large data storage and user-friendly software, and download
  • Easy to read, large well well-lit display
  • Built-in gas moisture removal

Applications

  • IVF
  • Research
  • Laboratories
  • Medical

    Enquire About This Product


    Title Size
    G100 Datasheet 2 MB

    Additional information

    Weight 0.09 kg

    Specifications

    POWER SUPPLY
    Battery type Li Ion
    Battery life 12 hours (10 hours with pump)
    Battery lifetime 600 cycles
    Battery charger 5Vdc external power supply and internal charging circuit
    Charge time 4 hours
    Alternative power 5Vdc power supply
    GAS RANGES
    Gases measured By custom dual wavelength infra-red with reference channel CO2
    By internal electrochemical cell O2 (optional)
    Oxygen cell lifetime Approximately 3 years in air
    Range 0-20%CO2
    0-100%O2
    Typical accuracy* ± 1% of range after calibration CO2
    ± 1% of range after calibration O2
    Response time T90 ≤ 20 seconds CO2
    ≤ 60 seconds O2
    *Typical accuracies All typical accuracies quoted are after calibration plus accuracy of calibration gas used.
    FACILITIES
    Temperature (optional) x 2 using optional probes 0°C to +50°C
    Temperature accuracy, typical ± 0.1°C from 32 to 44°C, ± 0.2°C over the rest of the range
    Barometric pressure 800 – 1200 mbar
    RH measurement (optional) RH Probe 0 -100% RH non condensing
    RH accuracy ± 1.5% RH across the range
    Visual and audible alarm User selectable CO2 and O2 alarm levels
    Communications USB type B mini-connector, HID device class
    Data storage 1000 reading sets + 270 events
    PUMP
    Flow 100cc / min typically
    ENVIRONMENTAL CONDITIONS
    Operating temperature 0°C to 50°C
    Relative humidity 0 – 95% non condensing (RH probe 0 – 100% non condensing)
    Barometric pressure ± 500mbar from calibration pressure
    IP rating IP40
    PHYSICAL
    Weight 495 grams
    Size L 165mm, W 100mm, D 55mm
    Case material ABS / polypropylene with silicone rubber inserts
    Keys 17 resin capped silicone rubber keys
    Display Liquid crystal display, 128 x 64 pixel
    With RGB LED back-light
    Gas sample filters Built-in gas dryer tube to remove moisture
    User replaceable PTFE water trap filter

      Enquire About This Product