Geotech G100 CO2 Incubator Analyser

Code: G100
  • Accurate CO2 readings
  • Quick verification of CO2 incubator levels
  • Time saving with dual temperature probes

In StockMake An Enquiry

The G100 CO2 analyser is specifically designed to monitor CO2 for the verification of incubators in research and pharmaceutical markets. This unit has been developed to incorporate the latest technology and specification requirements, which provide the user with a fast, simple-to-use and accurate piece of laboratory kit.

Features

  • CO2 0 – 20%
  • Options for:
    • O2 0-100%
    • Dual temperature probes 0 to 50°C
    • Data storage and download
    • Humidity sensor 0-100%

Benefits

  • Large data storage and user-friendly software, and download
  • Easy to read, large well well-lit display
  • Built-in gas moisture removal

Applications

  • IVF
  • Research
  • Laboratories
  • Medical

Enquire About This Product

Title Size
G100 Datasheet 2 MB

Additional information

Weight 0.09 kg

Specifications

POWER SUPPLY
Battery type Li Ion
Battery life 12 hours (10 hours with pump)
Battery lifetime 600 cycles
Battery charger 5Vdc external power supply and internal charging circuit
Charge time 4 hours
Alternative power 5Vdc power supply
GAS RANGES
Gases measured By custom dual wavelength infra-red with reference channel CO2
By internal electrochemical cell O2 (optional)
Oxygen cell lifetime Approximately 3 years in air
Range 0-20%CO2
0-100%O2
Typical accuracy* ± 1% of range after calibration CO2
± 1% of range after calibration O2
Response time T90 ≤ 20 seconds CO2
≤ 60 seconds O2
*Typical accuracies All typical accuracies quoted are after calibration plus accuracy of calibration gas used.
FACILITIES
Temperature (optional) x 2 using optional probes 0°C to +50°C
Temperature accuracy, typical ± 0.1°C from 32 to 44°C, ± 0.2°C over the rest of the range
Barometric pressure 800 – 1200 mbar
RH measurement (optional) RH Probe 0 -100% RH non condensing
RH accuracy ± 1.5% RH across the range
Visual and audible alarm User selectable CO2 and O2 alarm levels
Communications USB type B mini-connector, HID device class
Data storage 1000 reading sets + 270 events
PUMP
Flow 100cc / min typically
ENVIRONMENTAL CONDITIONS
Operating temperature 0°C to 50°C
Relative humidity 0 – 95% non condensing (RH probe 0 – 100% non condensing)
Barometric pressure ± 500mbar from calibration pressure
IP rating IP40
PHYSICAL
Weight 495 grams
Size L 165mm, W 100mm, D 55mm
Case material ABS / polypropylene with silicone rubber inserts
Keys 17 resin capped silicone rubber keys
Display Liquid crystal display, 128 x 64 pixel
With RGB LED back-light
Gas sample filters Built-in gas dryer tube to remove moisture
User replaceable PTFE water trap filter