System Specifications |
|
Classifications |
Class I, Divisions 1 & 2, Groups B, C, & D, Type 4X |
|
Class I, Zone 1, IIB + H2 |
|
(Ta=-40° C to +75° C) |
|
Ex d, IIB + H2 T5 Gb |
|
Ex tb IIIC, T100° C Db, IP66 |
|
(Ta=-60° C to +75° C) |
Warranty |
Two years |
Approvals |
ATEX, IECEx, CE, MED (IR4000S), |
|
DNV(IR4000S), FM 6310/6320 & |
|
CSA 22.2 No. 152 Performance approved |
|
HART registered (IR4000M) |
|
SIL 2 suitable (FM) |
Environmental Specifications |
|
Operating Temperature Range |
-40° F to +167° F (-40° C to +75° C) |
Storage Temperature Range |
-58° F to +185° F (-50° C to +85° C) |
Humidity Range |
10% to 95% RH, non-condensing |
Mechanical Specifications |
|
Length |
6.5″ (165 mm) |
Width |
6.0″ (152 mm) |
Height |
3.21″ (82 mm) |
Weight |
5.5 lbs (2.5 kg) |
Mounting Holes |
5.05″ (127 mm) center to center |
Housing |
Aluminum 6061-T6 alloy (cover) |
|
A356-T6 alloy (base) or 316 stainless steel |
Electrical Specifications |
|
Input Power |
|
IR4000M |
20-36 VDC @ 100 mA max |
IR4000S |
20-36 VDC @ 83 mA max 24 VDC nominal |
Analog Signal |
0-21.7 mA (600 ohms max.-IR4000M) |
|
0-21.7 mA (500 ohms max.-IR4000S) |
Status Indicators |
Three-digit LED display with gas concentration, Warn and Alarm LEDs, calibration prompts, fault codes, and setup options |
Relay Ratings (Optional) |
8 A @ 250 VAC / 8 A @ 30 VDC res. Max. |
|
(3x) SPDT – Warning, Alarm & Fault |
RS;485 Output (Optional) |
Single Modbus (IR4000S) or dual redundant Modbus RTU (IR4000M), suitable for linking up to 128 units or up to 247 units with repeaters |
Baud Rate |
2400, 4800, 9600, or 19200 BPS |
HART (Optional) |
HART 6, HART Device Descriptor available. |
|
AMS aware |
Faults Monitored |
Re-calibration error, EPROM Checksum error, Optics failure / blockage; low supply voltage, EEPROM checksum error, reference or active lamp failure, heater failure, time to re-zero unit |
Cable Requirements |
Max. distance between IR4000 and power source @ 24 VDC nominal (20 ohm loop): |
|
14 AWG (2.0 mm2) – 2606 ft (794 m) Max. distance for analog output (500
ohms max): |
|
14 AWG (2.0 mm2) – 9000 ft. (2740m) |
Wireless Communication |
Available with ELPRO Technologies wireless devices |
Standard Configuration |
IR4000S-0-0-02-1-0-1 IR400 (methane, 0-20 mA, splash guard w/screen), no relays, aluminum |
|
IR4000M-0-0-00-1-0-1-1 No relays, no Modbus, detector sold separately IR400 (methane, 0-20 mA, splash guard w/screen), no relays, aluminum |