The Drager Parat 3100 is designed for a 15-minute escape period. A half-mask covering the nose with a two-point head harness. Supplied in a robust case with traction grip areas and a grey security tag at the top, the unit should be serviced or replaced if opened.
Small, compact, easy to carry, 170 x 110 x 90 mm, weighing just 360g, worn using an integral belt clip. The filter expiry date and condition can be seen through the transparent cover. The Parat 3100 case is opened by pulling the yellow tag.
Fitted with an ABEK 15 gas filter offering protection for organic and inorganic gases and vapours, approved to DIN 58647 part 7. Maintenance-free with a 4-year life, replacing the filter every four years can extend the life to twelve years.
Also available in a vacuum-sealed aluminium bag designed for tropical climates, the Parat 3160 models form the Parat 3000 range.
Filter capacity according to DIN 58647-7 | ||||
Type | Test Gas | Concentration in PPM | Breakthrough in PPM | Minimum breakthrough time minute |
A | Cyclohexane (C6H12) | 2500 | 10 | 15 |
B | Chlorine (Cl2) | 2500 | 0.5 | 15 |
B | Hydrogen sulphide (H2S) | 2500 | 10 | 15 |
B | Hydrogen cyanide (HCN) | 2500 | 10 | 15 |
E | Sulphur dioxide (SO2) | 2500 | 5.0 | 15 |
K | Ammonia (NH3) | 2500 | 25 | 15 |
B | Hydrogen sulphide (H2S) | 10000 | 20 | 5 |
Test conditions: 30 L/min, 70% relative humidity, 20°C.
To determine the gas filter’s breakthrough capacity, it is additionally tested with 10,000 ppm hydrogen sulphide. |
Order Information
R57981 Parat 3100 Half mask with ABEK15 filter 3704476
R62630 Parat 3160 Half mask with ABEK15 filter 3704477
Accessories for training units
R56353 Parat 3100 Housing Cover, blue (training device component)
Replacement filters and parts
R57983 ABEK15 Replacement Filter (5 pieces). Previously R56350
R56355 Parat 3000 Security Tag (50 pieces)
R56319 Parat 3000 TPE Sealing Strap
R28175 Parat 3000 Carrying Belt