Drager PAC 6500 Single Gas Detector

Code: 8326330
  • Single gas monitor for personal air monitoring
  • Serviceable, non-disposable
  • Fast sensor response

In StockMake An Enquiry

The Drager Pac 6500 is a robust and reliable personal single-gas detection device that precisely measures CO, H2S, SO2 or O2. It can transmit data via Bluetooth into the Drager Gas Detection Connect system. Quick sensor response times and a powerful battery make it safe and efficient.

Strong performance for maximum safety

You can rely on the Drager Pac 6500: the personal single-gas detection device warns against hazardous concentrations of carbon monoxide, hydrogen sulphide, sulphur dioxide or oxygen with precision and reliability.

Powerful sensors with a T-90 low response time ensure quick reactions. The Pac 6500 is versatile thanks to its wide measurement range. For example, the CO sensor measures 1 to 1,999 ppm, and the H2S sensor measures concentrations from 0.4 to 100 ppm.

Easy handling thanks to clear user guidance

The D-Light indicates whether the device’s functionality has been tested and is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Drager Pac 6500 features visible colour coding, thereby minimising the chance of mistakes.

Robust design – even for the most challenging conditions

The Pac 6500 can easily handle even extreme conditions. Depending on the sensor, temperatures from -40 °C to 55 °C and air pressures between 700 and 1,300 mbar can be tolerated.

A membrane filter protects the sensor from foreign matter, such as dust and liquids. The shock-proof, chemical-resistant housing meets the requirements specified in the IP68 standard rating.

User-friendly display with all vital information

The large display is word-free and indicates the respective gas concentration. Other important information, such as the battery capacity, is also displayed. The bright backlighting ensures that all values are legible in the dark.

360° alarm with various functions

If the Drager Pac 6500 measures hazardous gas concentrations, it sets off an audible, visual and perceptible vibrating alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides. The acoustic signal reaches a volume of 90 dB. The display can show the peak concentration measured at any given moment. Earlier registered alarms can also be retrieved later, even if acknowledged.

Order Information

8326331 Pac 6500 CO, range 0-2000 ppm. Alarms 30/60 ppm
8326330 Pac 6500 H2S, range 0-100 ppm. Alarms 5/10 ppm
8326332 Pac 6500 O2, range 0-25 Vol%. Alarms 19/23 Vol%
8326333 Pac 6500 SO2, range 0-100 ppm. Alarms 0.5/1.0 ppm
8326341  Pac 6500 configurator part number, including Bluetooth

GATT licences

3721647 Drager Pac Open GATT licence (1 pc.)
3721648 Drager Pac Open GATT licence (10 pc.)
3721649 Drager Pac Open GATT licence (50 pc.)

Calibration accessories

8318588 Calibration adapter
8321881 Drager X-dock 5300 Pac
8317410 Drager Bump Test Station for Drager Pac, without gas cylinder
8318586 Drager Bump Test Station for Drager Pac, including one test gas cylinder (selectable gas and concentration)

Communication accessories

8318587 Communication module, including USB cable

Spare parts

8326856 Battery
8326853 Sensor grid (black)
8319186 Crocodile clip set

Enquire About This Product

Title Size
Pac 6500 Datasheet 633 KB

Additional information

Weight 0.190 kg
Models

Gas Clip for H2S, Gas Clip for CO, Gas Clip for O2

Specifications

Dimensions (without clip) W x H x D 64 x 84 x 20 mm
Weight Ca. 106 g (113 g mit Clip)
Battery service life 2 years (O2 sensors: 10 months)
Degree of protection IP68
Air pressure 700 to 1,300 hPa
Air humidity 10 to 90% relative humidity, non-condensing
Temperature -30 °C to +55 °C
(briefly down to -40 °C for 1 hr, depending on sensor)
Approvals
ATEX I M1 Ex ia I Ma
II 1G Ex ia IIC T4 Ga
IECEx Ex ia I Ma
Ex ia IIC T4 Ga
CSA (Canada & USA) Class I, Zone 0, AEx ia IIC T4 Ga
Class II, Division 1, Groups E, F, G
EAC PO Ex ia I Ma X
0Ex ia IIC T4 Ga X
MED Marine Equipment Directive (2014/90/EU)

Enquire About This Product