Detcon Model TP-524D

Code: TP-524D
  • Hydrogen Sulphide gas detector
  • MOS sensor
  • Ten-year conditional sensor warranty

In StockMake An Enquiry

The Detcon model TP-524D by Teledyne is a “Smart” gas detection sensor designed to detect and monitor H2S in the air over the ranges of 0-20 ppm, 0-50 ppm, and 0-100 ppm using a proprietary solid-state metal oxide semiconductor technology.

This innovative design offers several advantages, including longer sensor life and better temperature and humidity performance. Model TP-524D features Detcon’s MicroSafe intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics.

The sensor transmitter features an advanced universal design that fits all existing Detcon MOS H2S sensors dating back more than 20 years. The sensor assembly includes a MOS detector in a stainless steel housing, a base connector board, an explosion-proof enclosure (available in aluminium or stainless steel), a plug-in control transmitter circuit, and a splashguard with an integral calibration port. The packaging is Explosion Proof (Class I, Division 1, Groups B, C, D).

Model TP-524D is equipped with a standard analogue 4-20 mA current signal equivalent to the sensor range of detection, self-adjusting zero and span, and LED indicators for fault and calibration status. A HART communications option is also available. An industry-leading 10-year conditional warranty supports Detcon’s solid-state MOS sensor.

Features

  • cCSAus approved for Class I, Division 1, Groups B, C, & D.
  • Transmitter design fits all existing Detcon MOS H2S Sensors dating back 20 years.
  • Simple menu-driven calibration – less than 3 minutes.
  • LED display and LED indicators for FAULT and CAL status.
  • Plug-in field-replaceable transmitter.
  • Response similar to electrochemical sensors: T-50 <30 sec., T-90 <60 sec.
  • Direct response constant temperature control.
  • Withstands exposure to high-range concentrations of H2S and other acid gases.
  • Impervious to high moisture environments in both powered and non-powered modes.
  • Extensive Fault diagnostics.

Applications

  • Oil and Gas Drilling Rigs
  • Oil and Gas Production Sites
  • Offshore Production Platforms
  • FPSOs
  • LNG/CNG Plants
  • Refining and Petrochemical
  • Pulp and Paper Mills
  • Waste Water Treatment Plants

Order Information

TP-524 MOS Hydrogen Sulfide Gas Detection Sensor Assemblies
Semiconductor versions
965-015420-100 TP-524D Solid State MOS H2S Sensor Assembly in alum condulet
965-01542B-100 TP-524D-316SS Solid State MOS H2S Sensor Assembly in SS condulet
9H5-015420-100 TP-524D-HRT MOS H2S Sensor Assy w/HART alum condulet
9H5-01542B-100 TP-524D-HRT MOS H2S Sensor Assy w/HART SS condulet
Accessories
943-000000-000 Calibration Sleeve/Wind Guard for use with the splash guard
960-202200-000 Condensation prevention packet (for J-Box replace annually)
437-500000-000 Stainless steel tag
943-004223-000 2″ pipe mount with sun shade
943-004221-000 Sensor Mounting Plate for 2″ pipe
943-002273-000 Harsh location dust guard (fits 1.5 x 18 thread) Fits 700’s, FP 4,5,600’s, DM series 5,600’s,
033-003238-000 Harsh location dust guard replacement filter for 1.5 x 18 thread (Sold in a pack of qty 20 – order as 20ea)
943-002274-000 Hazardous location dust guard 7/8. Fits TP-4,5,600 series sensors.
943-003236-000 Harsh location dust guard replacement filter for (fits 1.5 x 18 thread) (Sold in a pack of qty 20)
943-003436-000 Harsh location water guard, fits all series with standard splash guard.
897-850000-010 Standard aluminium junction box with solid lid
897-850901-010 Standard aluminium junction box with lens cover
897-850000-316 Stainless steel junction box with solid cover
897-850901-316 Stainless steel junction box with lens cover
943-121747-SS5 Stainless steel flow-through adapter, Fits 700’s, FP 4,5,600’s, DM series 5,600’s, DM-100’s
Spare Parts
399-800000-000 Solid State MOS H2S Sensor in Stainless Steel Housing
925-0154D0-100 Plug-in transmitter control module (Model TP-524D)
925-015HD0-100 Plug-in transmitter module (Model TP-524D) with Hart
500-005230-100 Standard connector board Model series 400 & 500 sensors (old pn 500-005065-007)
326-000000-000 Replaceable sintered stainless steel flame arrestor
600-610000-000 Sensor splash guard w/integral cal port TP-424/TP-524/TP-624
943-000006-038 Calibration adapter TP
975-000020-891 Sensor Duct Mount Kit TP
943-002274-000 Harsh location dust guard (fits 7/8 x 14 thread)
033-003236-000 Harsh location dust guard replacement filter

    Enquire About This Product


    Title Size
    tp-524d brochure 88 KB
    tp-524d user manual 1 MB
    tp-524d hrt user manual 2 MB

    Additional information

    Weight 0.09 kg

    Specifications

    System Specifications
    Sensor Type Continuous diffusion/adsorption
    CHEMFET Solid State Metal Oxide Semiconductor
    Sensor Life 5 to 10 years typical
    Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm
    Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of )
    Response/Clearing Time T50 <30 seconds; T90 <60 seconds
    Outputs Linear 4-20 mA DC
    HART (optional)
    Electrical Classification Explosion proof
    CSAus
    Class I, Division 1, Groups B, C, D (Tamb = -25°C to +40°C)
    Class I, Zone 1, Group IIB+H2
    cCSA
    Class I, Division 1, Groups B, C, D (Tamb = -40°C to +40°C)
    Class I, Zone 1, Group IIB+H2
    FM
    Class I, Division 1, Groups B, C, D (Tamb = -40°C to +60°C)
    Complies with ANSI/ISA 92.00.01-2010
    ATEX
    Ex d IIB+H2 T4 (Tamb = -40°C to +60°C)
    Ingress Protection NEMA 4X, IP66
    Warranty Plug-in detector – 10-year conditional
    Transmitter – 2 year
    Environmental Specifications
    Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA)
    -25°C to +40°C; -13°F to 104°F (USA)
    Storage Temperature Range -35°C to +55°C; -13°F to +131°F
    Operating Humidity Range 5-100% RH non-condensing
    Operating Pressure Range Atmospheric ±10%
    Mechanical Specifications
    Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D
    254mmH x 155mmW x 109mmD
    Mounting holes (J-box) 5.5”; 140mm centre to centre
    Weight 6 lbs; 2.72kg (w/aluminum j-box)
    9 lbs; 4.08kg (w/stainless steel j-box)
    Electrical Specifications
    Power Input 12-28 VDC
    Power Consumption Normal operation = 68mA (<1.7 watt)
    Maximum = 85mA (2 watts)
    RFI/EMI Protection Complies with EN 50270
    Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
    0mA All Fault Diagnostics
    2mA In-Calibration
    4-20mA 0-100% full-scale
    22mA Over-range condition
    Status Indicators 4-digit LED display with gas concentration
    Full-script menu prompts for AutoSpan,
    Set-up Options and Fault Reporting
    LEDs for Fault and Calibration
    Faults Monitored Heater, Loop, Input Voltage
    Sensor, Processor, Memory, Calibration
    Cable Requirements Power/Analog
    3-wire shielded cable
    Maximum distance is 13,300 feet with 14 AWG
    I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity

      Enquire About This Product