Detcon Model X40 Alarm & Control System

Code: X40
  • 8 to 32 channel capacity
  • Backlit LCD screen display
  • Analogue or RS-485 input options

In StockMake An Enquiry

Detcon Model X40 is a low-power alarm and control system designed to monitor multiple gas detection sensors and a wide range of other field devices.

The versatile control system is designed to receive and supervise inputs using either 4-20mA DC or Serial RS-485 Modbus and is available in two packages: Model X40-8 and Model X40-32. Both packages function as a Modbus Master and can be customised and expanded based on individual application needs using the stackable DIN-rail-mounted I/O modules. All I/O modules are individually addressable and operate on 11.5-30VDC. The X40-8 provides power for up to eight field devices and can house up to six 4-channel I/O modules.

The Model X40-32 provides power for up to 32 field devices and can house up to 12 4-channel I/O modules. The I/O modules available for use with the Model X40 include a 4-channel 4-20mA input module (DA-4), a 4-alarm relay output module (RL-4), a 4-channel 4-20mA output module (AO-4), and a 4-relay contact input module (DI-4). The modules can be mounted within the main system enclosure or installed remotely to simplify field wiring.

The Model X40 is completely field programmable using a small handheld magnet and offers advanced technology with intuitive, embedded intelligence. The control system displays real-time readings and field device status on a backlit LCD screen. The screen displays the alarm status and current reading (i.e., channel number, gas type, and gas concentration) for up to eight field devices simultaneously.

The display is sequential, and during regular operation, it auto cycles through each of the active channel screens. Among the system’s unique features is a wireless option that can be used with RXT-320 SmartWireless transceivers. Enclosure options include NEMA 4X, NEMA 1 panel mount, and NEMA 7.

Features

  • Easy, intuitive field configuration
  • Wire or distributed I/O
  • Extensive event data logging
  • SmartWireless capable

Order Information

Model X40 Gas Detection Systems N1, N4X, N7
95P-X32000-000 Model X40-32-N1P, integrated alarm and control system in panel mount enclosure Does not include optional I/O modules (Accepts a maximum of 2). Power supply for 32 sensors
95R-X32000-000 Model X40-32-N1P, integrated alarm and control system in 19″ Rack mount enclosure w/ 110/220 VAC 24 VDC pwr supply for 32 sensors Does not include optional I/O modules(Accepts a maximum of 2)
954-X32020-000 Model X40-32-N4X, integrated alarm and control system in wall mount weatherproof Stainless Steel enclosure w/ 110/220 VAC 24 VDC pwr supply for 32 sensors. Does not include optional I/O modules (Accepts a maximum of 15)
954-X32030-000 Model X40-32-N4X, integrated alarm and control system in wall mount BBU, Stainless Steel weatherproof enclosure w/ 110/220 VAC 24 VDC pwr supply for 32 sensors, with Battery Back Up. Does not include optional I/O modules (Accepts a maximum of 15)
957-X32000-000-0_0 Model X40-00-N7, integrated alarm and control system in wall mount explosion proof enclosure (Class I; Div 1: Group C, D). Requires external 10-30 VDC power supply. Strobe Options are not available on C1 Div 1 versions. (This enclosure does not accept internal I/O
954-X08000-000 Model X40-08-N4X, integrated alarm and control system in wall mount weatherproof enclosure with 110/220 VAC 24 VDC power supply for 8 sensors. Does not include optional I/O modules
954-X32000-000 Model X40-32-N4X, integrated alarm and control system in wall mount weatherproof enclosure w/ 110/220 VAC 24 VDC power supply for 32 sensors. Does not include optional I/O modules
I/O Modules
976-041400-000 Detcon Model DA-4 four channel 4-20 maDC input module
975-041400-000 Detcon Model RL-4 four relay alarm module
975-041402-000 Detcon Model DI-4 four channel dry contact input module
975-041401-000 Detcon Model AO-4 four channel analog output module
976-485485-000 RS-485 Isolated Repeater, 9-30VDC
Remote IO Nodes and Enclosure Options
Does not include I/O modules
954-R20260-000 NEMA 4X Remote I/O Module Enclosure includes 75 watt power supply, for use with up to 8
  X40 Sentinel controllers Spare Parts
976-0003BC-00T Battery Charger / Cord
976-042405-000 5 Db Rubber Antenna
600-003846-000 8″ Antenna Raydome Dust cover for whip antenna
980-SPXSJX-006 2 meter whip antenna extension
360-3S6PFP-ASM Flat Battery Pack
320-N45161-000 Power Switch
302-RSFCCO-05m Connector Dust Cap
976-001320-CHR Radio Module with charger circuit included
275-556160-432 Power LED Indicator
980-NTNT40-030 10 meter Antenna cable
976-042407-000 High gain 7db antenna with bracket
500-005221-200 Main control board w/display
949-005142-200 Drop-in X40 Control Assembly with bezel
360-ML0100-024 PULS 24VDC 4.2Amp 100W Power Supply din rail mount power supply
995-SDSDB2-048 Data Log Memory, 2GB SD Flash Card
327-000000-000 Programming Magnet
  Obsolete Parts
957-XRD640-110-0_0 Model X40-RD-N7, 32 Channel Remote Display panel in cast aluminum enclosure: Class 1; Div 1; Grps C, D. Requires 24VDC input. Strobe options are not available on the C1 Div 2 versions
954-XRD640-110 Model X40-RD-N4, 64 Channel Remote Display panel in N4X enclosure; 120VAC and wall mounting
954-R21610-000 NEMA 4X Remote I/O Module Enclosure includes a 120-watt power supply for use with up to 8 I/O modules, 32 sensors
957-R11662-000 NEMA 7X Remote I/O Module Enclosure includes a 75-watt power supply for use with up to 8 I/O modules, 32 sensors
901-100000-000 X40/MCX 32 Data Logging PC Firmware Program

Enquire About This Product

Title Size
Detcon-x40-brochure 193 KB

Specifications

SYSTEM SPECIFICATIONS
System Capacity Model X40-32-N1P: Up to 32 field devices
Model X40-8-N4X: Up to 8 field devices
Model X40-32-N4X: Up to 32 field devices
Model X40-32-N7: Up to 32 field devices
(analog or serial)
Indicators 1 1/8 ” by 5 3/4” backlit LCD Alarm status LEDs
Display Accuracy ±1% of full scale value
Input Options Analog 4-20 mA DC
RS-485 Modbus™ *(Only compatible with other Detcon products)
Relay Contacts
* Option for Model X40-32-N7
Output Options 4-20 mA DC
RS-485 Modbus™
Relay Contacts
Safety Approvals CE Marking (Models X40-N4X & X40-SS)
Warranty One Year
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature Range -4ºF to + 158ºF, -20ºC to + 70ºC
Storage Temperature Range -40ºF to + 185ºF, -40ºC to + 85ºC
Operating Humidity Range 0-99% RH non-condensing
MECHANICAL SPECIFICATIONS
Dimensions Model X40-32-N1P: 10.5”W x 8”H x 12”D
Model X40-8-N4X: 12”W x 14”H x 7.75”D
Model X40-32-N4X: 16”W x 17.85”H x 9.5”D
Model X40-32-N7: 11”W x 9.15”H x 2.75”D
Weight Model X40-32-N1P: 10 lbs
Model X40-8-N4X: 10 lbs
Model X40-32-N4X: 20 lbs
Model X40-32-N7: 10 lbs
ELECTRICAL OPTIONS
Power Input 115-230 VAC* or 11.5-30 VDC
Power Consumption <0.25 Watt
(I/O module power consumption not included)
(Field device power consumption not included)
Electrical Classification Model X40-32-N1P: NEMA 1 Panel Mount
Model X40-8-N4X: NEMA 4X Corrosion resistant weatherproof
Model X40-32-N4X: NEMA 4X Corrosion resistant weatherproof
Model X40-32-N7: NEMA 7 Class I; Division 1, Group C, D

Enquire About This Product