Detcon Model TP-624D

Code: TP-624D
  • Hydrogen Sulphide Gas Detector
  • MOS Sensor
  • Ten-year conditional sensor warranty

In StockMake An Enquiry

The Detcon model TP-624D by Teledyne is a “Smart” gas detection sensor designed to detect and monitor H2S in the air over the ranges of 0-20 ppm, 0-50 ppm, and 0-100 ppm using a proprietary solid-state metal oxide semiconductor technology. This innovative design offers several advantages, including longer sensor life and better temperature and humidity performance.

Model TP-624D features Detcon’s MicroSafe intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon MOS H2S sensors dating back more than 20 years. The sensor assembly includes a MOS detector in a stainless steel housing, a base connector board, an explosion-proof enclosure (available in aluminium or stainless steel), a plug-in control transmitter circuit, and a splashguard with an integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups B, C, D).

Equipped with a standard analogue 4-20 mA current signal equivalent to the sensor range of detection, RS-485 serial communications port, one-person remote calibration, self-adjusting zero and span, and LED indicators for two alarm relays and one fault relay and calibration status.

Features

  • cCSAus approved for Class I, Division 1, Groups B, C, & D Transmitter design fits all existing Detcon MOS H2S sensors dating back 20 years.
  • Compatible with PLCs, SCADA, DCS, via 0-20 mA, and/or RS-485, and/or alarm relays.
  • Sensor status and parameters are accessible via RS-485 (Modbus).
  • Menu programmable relays standard (two alarms plus fault).
  • Simple menu-driven calibration- less than 3 minutes.
  • LED display and LED indicators for FAULT and CAL status.
  • Plug-in field-replaceable transmitter.
  • Response similar to electrochemical sensor: T50 <30sec., T80 <60 sec.
  • Direct response constant temperature control.
  • Withstands exposure to high-range concentrations of H2S and other acid gases.
  • Impervious to high moisture environments in both powered and non-powered modes.
  • Extensive Fault diagnostics.
  • Replaces model TP-624C.

Applications

  • Oil and Gas Drilling Rigs
  • Oil and Gas Production Sites
  • Refining and Petrochemical
  • Pulp and Paper Mills
  • Waste Water Treatment Plants

Order Information

TP-624 Series MOS Hydrogen Sulfide Gas Detection Sensor Assemblies
966-014520-100 TP-624D Solid State MOS H2S Sensor Assembly Alum Condulet
966-01452B-100 TP-624D-316SS Solid State MOS H2S Sensor Assembly 316SS condulet
Accessories
943-000000-000 Calibration Sleeve/Wind Guard for use with splash guard
960-202200-000 Condensation prevention packet (for J-Box replace annually)
437-500000-000 Stainless steel tag
943-004223-000 2″ pipe mount with sun shade
943-004221-000 Sensor Mounting Plate for 2″ pipe
943-002273-000 Harsh location dust guard (fits 1.5 x 18 thread) Fits 700’s, FP 4,5,600’s, DM series 5,600’s,
033-003238-000 Harsh location dust guard replacement filter for 1.5 x 18 thread (Sold in a pack of qty 20 – order as 20ea)
943-002274-000 Hazardous location dust guard 7/8 Fits TP-4,5,600 series sensors.
943-003236-000 Harsh location dust guard replacement filter for (fits 1.5 x 18 thread) (Sold in a pack of qty 20)
943-003436-000 Harsh location water guard, fits all series with standard splsh guard.
897-850000-010 Standard aluminum junction box with solid lid
897-850901-010 Standard aluminum junction box with lens cover
897-850000-316 Stainless steel junction box with solid cover
897-850901-316 Stainless steel junction box with lens cover
943-121747-SS5 Stainless steel flow through adapter, Fits 700’s, FP 4,5,600’s, DM series 5,600’s, DM-100’s
TP-624D Solid State MOS H2S Sensor Assembly Spare Parts
399-800000-000 Solid State MOS H2S Sensor in Stainless Steel Housing
926-0155D0-100 Plug-in transmitter control module (Model TP-624D)
500-005231-100 Standard connector board Model series 600 sensors (Old PN 500-001794-004)
600-610000-000 Sensor splash guard w/integral cal port TP-424/TP-524/TP-624
943-000006-038 Calibration adapter TP
326-000000-000 Replaceable sintered stainless steel flame arrestor
975-000020-891 Sensor Duct Mount Kit TP
943-002274-000 Harsh location dust guard (fits 7/8 x 14 thread)
033-003236-000 Harsh location dust guard replacement filter
Model Series 600 Universal Spare Parts
327-000000-000 Magnetic programming tool
960-202200-000 Condensation prevention packet (for J-Box replace annually)
437-500000-000 Stainless steel tag
943-004223-000 2″ pipe mount with sun shade
943-004221-000 Sensor Mounting Plate for 2″ pipe
975-225007-006 Remote sensor Sepration Jbox, aluminum, 6 wire terminal strip
975-316007-006 Remote sensor separation Jbox, 316 stainless steel, 6 wire terminal strip
897-850901-010 Standard aluminum junction box with lens cover
897-850901-316 Standard 316SS junction box with lens cover
943-003436-000 Harsh location water guard
943-000000-000 Calibration Sleeve/Wind Guard for use with splash guard
Obsolete Parts
9H6-014520-100 TP-624D-HRT Solid State MOS H2S Sensor Assembly Alum condulet with Hart
9H6-01452B-100 TP-624D-HRT Solid State MOS H2S Sensor Assembly 316SS condulet with Hart

Enquire About This Product

Title Size
tp-624d brochure 93 KB
tp-624d user manual 1 MB

Additional information

Weight 0.09 kg

Specifications

System Specifications
Sensor Type Continuous diffusion/adsorption
CHEMFET Solid State Metal Oxide Semiconductor
Sensor Life 5 to 10 years typical
Measurement Range 0-20 ppm, 0-50 ppm, 0-100 ppm
Accuracy/Repeatability ±10% of reading or ±2 ppm (greater of )
Response/Clearing Time T50 <30 seconds; T80 <60 seconds
Outputs Linear 4-20 mA DC
RS-485 MODBUS-RTU
3 Relays (alarm 1, alarm 2, & fault)
Contacts rated 5 amps
Electrical Classification Explosion proof
CSAus
Class I, Division 1, Groups B, C, D (Tamb = -25°C to +40°C) )
Class I, Zone 1, Group IIB+H2
cCSA
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +40°C)
Class I, Zone 1, Group IIB+H2
ATEX
Ex d IIB+H2 T4 (Tamb = -40°C to +60°C)
Safety Approvals cCSAus
ATEX
CE Marking
  SIL2 FMEDA Rating
Ingress Protection IP66
Warranty Plug-in detector – 10 year conditional
Transmitter – 2 year warranty
Environmental Specifications
Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA)
-25°C to +40°C; -13°F to 104°F (USA)
Storage Temperature Range -35°C to +55°C; -13°F to +131°F
Operating Humidity Range 5-100% RH non-condensing
Operating Pressure Range Atmospheric ±10%
Mechanical Specifications
Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D
254mmH x 155mmW x 109mmD
Mounting holes (J-box) 5.5”; 140mm center to center
Weight 6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input 22-28 VDC*
Power Consumption Normal operation = 68mA (<1.7 watt)
Maximum = 85mA (2 watts)
RFI/EMI Protection Complies with EN 50270
Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA All Fault Diagnostics
2mA In-Calibration
4-20mA 0-100% full-scale
22mA Over-range condition
Serial RS-485 Output RS-485 Modbus™ RTU
Baud Rate 9600 BPS (9600,N,8,1 Half Duplex)
Status Indicators 4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting
4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration
Relay Outputs Alarm 1, Alarm 2, and Fault
5A @ 250VAC
5A @ 30VDC
Faults Monitored Heater, Loop, Input Voltage
Sensor, Processor, Memory, Calibration
Cable Requirements Power/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair shielded cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity
* 12 VDC available by special order

Enquire About This Product