Detcon Model FP-624D

Code: FP-624D
  • Flammable Gas Detector
  • Catalytic Sensor
  • Easy to use

In StockMake An Enquiry

The Detcon model FP-624D by Teledyne is a “Smart” gas detection sensor designed to detect and monitor combustible gas in the air over the range of 0-100% LEL (lower explosive limit) using matched-pair catalytic bead technology.

Model FP-624D features Detcon’s MicroSafeTM intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon matched-pair catalytic bead sensors, dating back over 20 years.

The sensor assembly includes the detector in a stainless steel housing, a base connector board, an explosion-proof enclosure (available in aluminium or stainless steel), a plug-in control transmitter circuit, and a splashguard with an integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups C & D).

Equipped with a standard analogue 4-20 mA current signal equivalent to the sensor range of detection, RS-485 serial communications port, two alarm relays and one fault relay, one-person remote calibration, self-adjusting zero and span, and LED indicators for fault, alarm, and calibration status. Detcon’s combustible gas sensor has an infinite shelf life and is supported by a 2-year warranty.

Features

  • Performance Certified to CSA 152 cCSAus for Class I, Division 1, Groups C & D.
  • Transmitter design fits all existing Detcon Catalytic Bead Sensors dating back 20 years.
  • Compatible with PLCs, SCADA, DCS, via 4-20 mA, and/or RS485, and/or alarm relays.
  • Sensor status and parameters are accessible via RS-485 (Modbus).
  • Menu programmable relays standard (two alarms plus fault).
  • Simple menu-driven calibration – less than 3 minutes.
  • LED display with LED indicators for FAULT and CAL status.
  • Plug-in field-replaceable transmitter.
  • Long sensor life: averaging +5 years in harsh offshore drilling/production environments.
  • High resistance to poisons such as sulfides, chlorides, silicon-based contaminants, etc.
  • Low power consumption (less than 3.5 watts versus 8+ watts on competitive brands).
  • Extensive Fault diagnostics.

Applications

  • Oil and Gas Drilling Rigs
  • Oil and Gas Production Sites
  • Offshore Production Platforms
  • FPSOs
  • LNG/CNG Plants
  • Refining and Petrochemical
  • Pulp and Paper Mills
  • Waste Water Treatment Plants

Order Information

FP-624 Catalytic Combustible Gas Detection Sensor Assemblies
966-524520-100 FP-624D Catalytic Combustible Gas Sensor Assembly Alum condulet
966-52452B-100 FP-624D Catalytic Combustible Gas Sensor Assembly 316SS condulet
Accessories
943-000000-000 Calibration Sleeve/Wind Guard for use with splash guard
960-202200-000 Condensation prevention packet (for J-Box replace annually)
437-500000-000 Stainless steel tag
943-004223-000 2″ pipe mount with sun shade
943-004221-000 Sensor Mounting Plate for 2″ pipe
943-002273-000 Harsh location dust guard (fits 1.5 x 18 thread) Fits 700’s, FP 4,5,600’s, DM series 5,600’s,
033-003238-000 Harsh location dust guard replacement filter for 1.5 x 18 thread (Sold in a pack of qty 20 – order as 20ea)
943-002274-000 Hazardous location dust guard 7/8 Fits TP-4,5,600 series sensors.
943-003236-000 Harsh location dust guard replacement filter for (fits 1.5 x 18 thread) (Sold in a pack of qty 20)
943-003436-000 Harsh location water guard, fits all series with standard splsh guard.
897-850000-010 Standard aluminum junction box with solid lid
897-850901-010 Standard aluminum junction box with lens cover
897-850000-316 Stainless steel junction box with solid cover
897-850901-316 Stainless steel junction box with lens cover
943-121747-SS5 Stainless steel flow through adapter, Fits 700’s, FP 4,5,600’s, DM series 5,600’s, DM-100’s
FP-624 Catalytic Combustible Gas Sensor Assembly Spare Parts
370-201600-000 Combustible gas field replaceable plug-in sensor
926-5255D0-100 Plug-in transmitter module (Model FP-624D)
500-001794-004 Standard connector board Model series 600 sensors
612-820000-000 Stainless steel LEL sensor housing with threaded insert
399-602016-000 Stainless steel LEL sensor housings including plug-in sensor
613-120000-700 Sensor splash guard with integral cal-port – FP/DM/IR
943-000006-132 Calibration adapter FP/IR/DM/O2
975-000020-890 Sensor Duct Mount Kit LEL
612-400000-000 Sensor/Sintered Filter replacement wrench FP/DM/IR
943-002273-000 Harsh location dust guard (fits 1.5 x 18 thread)
033-003238-000 Harsh location dust guard replacement filter for 1.5 x 18 thread (Sold in a pack of qty 20 – order as 20ea)
Model Series 600 Universal Spare Parts
327-000000-000 Magnetic programming tool
960-202200-000 Condensation prevention packet (for J-Box replace annually)
437-500000-000 Stainless steel tag
943-004223-000 2″ pipe mount with sun shade
943-004221-000 Sensor Mounting Plate for 2″ pipe
975-225007-006 Remote sensor Sepration Jbox, aluminum, 6 wire terminal strip
975-316007-006 Remote sensor separation Jbox, 316 stainless steel, 6 wire terminal strip
897-850901-010 Standard aluminum junction box with lens cover
897-850901-316 Standard 316SS junction box with lens cover
943-003436-000 Harsh location water guard
943-000000-000 Calibration Sleeve/Wind Guard for use with splash guard
Obsolete Parts
9H6-524520-100 FP-624D-HRT Catalytic Combustible Gas Sensor Assembly Alum condulet with Hart
9H6-52452B-100 FP-624D-HRT Catalytic Combustible Gas Sensor Assembly 316SS condulet with Hart
926-525HD0-100 Plug-in transmitter module (Model FP-624D) with Hart

Enquire About This Product

Title Size
fp-624d brochure 97 KB
fp-624d user manual 965 KB

Additional information

Weight 0.09 kg

Specifications

System Specifications
Sensor Type Matched-pair catalytic bead
Sensor Life 3 to 5 years typical
Measurement Range 0-100% LEL (lower explosive limit)
Accuracy/Repeatability ±3% 0-50% LEL
±5% 50-100% LEL
Response/Clearing Time T50 <10 seconds; T90 <30 seconds
Zero Drift <5% per year
Outputs Linear 4-20 mA DC
HART (optional)
3 Relays (alarm 1, alarm 2, & fault)
Contacts rated 5 amps
Electrical Classification Explosion proof
CSAus
Class I, Division 1, Groups C, D (Tamb = -25°C to +40°C)
Class I, Zone 1, Group IIB
cCSA
Class I, Division 1, Groups C, D (Tamb = -40°C to +40°C)
Class I, Zone 1, Group IIB
Performance Approvals CSA C22.2 #152
Safety Approvals cCSAus
Ingress Protection NEMA 4X, IP66
Warranty Sensor: 2 year warranty
Transmitter: 2 year warranty
Environmental Specifications
Operating Temperature Range -40°C to +40°C; -40°F to 104°F (CANADA)
-25°C to +40°C; -13°F to 104°F (USA)
Storage Temperature Range -40°C to +75°C; -40°F to +167°F
Operating Humidity Range 0-99% RH non-condensing
Operating Pressure Range Atmospheric ±10%
Mechanical Specifications
Dimensions 10”H (including splashguard) x 6.1”W x 4.3”D
254mmH x 155mmW x 109mmD
Mounting holes (J-box) 5.5”; 140mm center to center
Weight 6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input 12 – 28 VDC
Power Consumption Normal operation = 68mA (<1.7 watt)
Maximum = 87mA (2 watts)
RFI/EMI Protection Complies with ISO 92.0.01
Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA All Fault Diagnostics
2mA In-Calibration
4-20mA 0-100% full-scale
22mA Over-range condition
Status Indicators 4-digital LED display with gas concentration
Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting
4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration
Relay Outputs Alarm 1, Alarm 2, and Fault
5A @ 250VAC
5A @ 30VDC
Faults Monitored Loop, Input Voltage, Zero Sensor, Processor, Memory, Calibration
Cable Requirements Power/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output 2-wire twisted-pair shielded cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity

Enquire About This Product