The SMART 3G-D3 Gas Detector with Infrared sensor is designed to meet industrial requirements; the enclosure is explosion-proof and can be installed in ATEX Zone 2 and, when equipped with a dust adapter, in Zone 22.
The sensing element is placed in the stainless steel head with a 47.5 mm diameter. The infrared sensors employed for flammable and refrigerant gas detection are poison-free, with high accuracy and a long lifetime.
The gas detector has a 12-24 Vdc power supply, a standard 4-20 mA 3-wires output, and three relays. Optionally, the SMART3G-D3 can be equipped with serial RS485 communication.
The enclosure has dimensions 106 x 160 x 81 mm; on the upper side, there’s a M20 cable gland. The SMART3G-D3 features a 7-segment display for real-time concentration visualization and Hall effect sensors for non-intrusive field calibration.
SMART3G-D3 is SIL2 hardware and SIL3 software with a redundant system; the hardware is SIL3.
Order Information
SMART3G-D3 – FLAMMABLE GAS (Infrared sensor) | |
S2625ME | METHANE detector, 4-20 mA, 0-100% LFL |
S2601PR | PROPANE detector, 4-20 mA, 0-100% LFL |
S2601BU | BUTANE detector, 4-20 mA, 0-100% LFL |
S2601GP | LPG detector, 4-20 mA, 0-100% LFL |
S4434R454B | R454B detector, 4-20 mA, 0-100% LFL |
S4828R454C | R454C detector, 4-20mA, 0-100% LFL |
S3426R32 | R32 DIFLUOROMETHANE detector, 4-20 mA, 0-100% LFL |
S3430R1234YF | R1234yf detector, 4-20 mA, 0-100% LFL |
S3435R1234ZE | R1234ze detector, 4-20 mA, 0-100% LFL |
SMART3G-D3 – CO2 (Infrared sensor) | |
S2631CO2 | CARBON DIOXIDE (CO2) detector, 0-2% Vol., 4-20 mA |
S2632CO2 | CARBON DIOXIDE (CO2) detector, 0-5% Vol., 4-20 mA |
S2447CO2 | CARBON DIOXIDE (CO2) detector, 0-30% Vol., 4-20 mA |
S2448CO2 | CARBON DIOXIDE (CO2) detector, 0-5000 ppm, 4-20 mA |
S2633CO2 | CARBON DIOXIDE (CO2) detector, 0-100% Vol., 4-20 mA |
SMART3G-D3 – SF6 and REFRIGERANT GASES (Infrared sensor) | |
S3943R32 | R32 detector, 0-2000 ppm, 4-20 mA |
S3597R134A | R134a detector, 0-2000 ppm, 4-20 mA |
S3600SF6 | SF6 detector, 0-2000 ppm, 4-20 mA |
S3651R125 | R125 detector, 0-2000 ppm, 4-20 mA |
S3652R1234YF | R1234yf detector, 0-2000 ppm, 4-20 mA |
S3947R1234ZE | R1234ze detector, 0-2000 ppm, 4-20 mA |
S3653R404A | R404A detector, 0-2000 ppm, 4-20 mA |
S3654R407A | R407A detector, 0-2000 ppm, 4-20 mA |
S3919R407F | R407F detector, 0-2000 ppm, 4-20 mA |
S3922R449A | R449 detector, 0-2000 ppm, 4-20 mA |
S3655R507A | R507A detector, 0-2000 ppm, 4-20 mA |
S3672R410A | R410A detector, 0-2000 ppm, 4-20 mA |
S3951R417A | R417A detector, 0-2000 ppm, 4-20 mA |
S3955R448 | R448 detector, 0-2000 ppm, 4-20 mA |
ACCESSORIES | |
STS/CSW+ | Calibration software for SMART3G, SMART3NC & SMART3R detectors consisting of a USB key, a USB/RS485 converter and the STS/IDI card. The software runs on Windows XP, Windows 7, and Windows 10. The calibration software allows the modification of the alarm thresholds and the measuring range and allows adjusting the Zero, Span and 4-20 mA values via a user-friendly menu, either in situ or in the laboratory. |
STS/IDI | Plug-in interface for RS485 serial communication suitable for SMART3G |
STGD/AD3 | Adapter for all sensor heads (exception made for S2096__ & S2097__) to upgrade the protection from G to GD |