The Sensitron SMART3G-C3 gas detector is designed to meet industrial requirements. Its enclosure is explosion-proof and can be installed in ATEX Zone 2 and, when equipped with a dust adapter, Zone 22.
The sensing element is placed in the stainless steel head with a 40 mm diameter.
The infrared sensors employed for flammable and refrigerant gas detection are poison-free, have high accuracy, and have a long lifetime.
The gas detector has a 12-24 Vdc power supply and a standard 4-20 mA 3-wire output. Optionally, the SMART3G-C3 can be equipped with serial RS485 communication and a 1 or 3 relay board.
The enclosure measures 106 x 160 x 62 mm and has an M20 cable gland on the upper side.
Order Information
SMART3G-C3 – FLAMMABLE GAS (Catalytic sensor) | |
CR2096ME | METHANE detector, 4-20 mA, 0-100% LFL |
CR2096GP | LPG detector, 4-20 mA, 0-100% LFL |
CR2096BU | BUTANE detector, 4-20 mA, 0-100% LFL |
CR2096PR | PROPANE detector, 4-20 mA, 0-100% LFL |
CR2096VB | PETROL VAPOURS detector, 4-20 mA, 0-100% LFL |
CR2096H2 | HYRDOGEN detector 4-20mA, 0-100% LFL |
SMART3G-C3 – FLAMMABLE GAS (Infrared sensor) | |
CR2623ME | METHANE detector, 4-20 mA, 0-100% LFL |
CR2653BU | BUTANE detector, 4-20 mA, 0-100% LFL |
CR2653PR | PROPANE detector, 4-20 mA, 0-100% LFL |
CR2653GP | LPG detector, 4-20 mA, 0-100% LFL |
CR4432R454B | R454B detector, 4-20 mA, 0-100% LFL |
CR3424R32 | R32 DIFLUOROMETHANE detector, 4-20 mA, 0-100% LFL |
CR3428R1234YF | R1234yf detector, 4-20 mA, 0-100% LFL |
CR3432R1234ZE | R1234ze detector, 4-20 mA, 0-100% LFL |
SMART3G-C3 – TOXIC GASES (Electrochemical cell) | |
CR2640O2 | OXYGEN (O2) detector, 0-25% Vol., 4-20 mA |
CR2130CO | CARBON MONOXIDE (CO) detector, 0-500 ppm, 4-20 mA |
CR2130EL | ETHYLENE (C2H4) detector, 0-200ppm |
CR3224AM | AMMONIA (NH3) detector, 0-100 ppm, 4-20 mA |
CR2132AM | AMMONIA (NH3) detector, 0-200 ppm, 4-20 mA |
CR2134AM | AMMONIA (NH3) detector, 0-1000 ppm, 4-20 mA |
CR3228AM | AMMONIA (NH3) detector, 0-5000 ppm, 4-20 mA |
CR2136HS | HYDROGEN SULPHIDE (H2S) detector, 0-50 ppm, 4-20 mA |
CR2144NO | NITRIC OXIDE (NO), 0-100 ppm, 4-20 mA |
CR3592H2 | HYDROGEN (H2) detector, 0-2000 ppm, 4-20 mA |
CR4546H2 | HYDROGEN (H2) detector, 0-3000 ppm, 4-20 mA |
SMART3G-C3 – CO2 (Infrared sensor) | |
CR2649CO2 | CARBON DIOXIDE (CO2) detector, 0-2% Vol., 4-20 mA |
CR2650CO2 | CARBON DIOXIDE (CO2) detector, 0-5% Vol., 4-20 mA |
CR2443CO2 | CARBON DIOXIDE (CO2) detector, 0-30% Vol., 4-20 mA |
CR2444CO2 | CARBON DIOXIDE (CO2) detector, 0-5000ppm, 4-20 mA |
CR2629CO2 | CARBON DIOXIDE (CO2) detector, 0-100% Vol., 4-20 mA |
SMART3G-C3 – VOC detectors (PID sensors) | |
CR3540IL | VOC detector, 0-20ppm, 4-20mA (Isobutylene) |
CR3544IL | VOC detector, 0-200ppm, 4-20mA (Isobutylene) |
CR5121IL | VOC detector, 0-2000ppm, 4-20mA (Isobutylene) |
SMART3G-C3 – SF6 and REFRIGERANT GASES (Infrared sensor) | |
CR3942R32 | R32 detector, 0-2000 ppm, 4-20 mA |
CR3595R134A | R134a detector, 0-2000 ppm, 4-20 mA |
CR3598SF6 | SF6 detector, 0-2000 ppm, 4-20 mA |
CR3020R125 | R125 detector, 0-2000 ppm, 4-20 mA |
CR3021R1234YF | R1234yf detector, 0-2000 ppm, 4-20 mA |
CR3025R1234ZE | R1234ze detector, 0-2000 ppm, 4-20 mA |
CR3022R404A | R404A detector, 0-2000 ppm, 4-20 mA |
CR3023R407A | R407A detector, 0-2000 ppm, 4-20 mA |
CR3918R407F | R407F detector, 0-2000 ppm, 4-20 mA |
CR3921R449A | R449 detector, 0-2000 ppm, 4-20 mA |
CR3024R507A | R507A detector, 0-2000 ppm, 4-20 mA |
CR3016R410A | R410A detector, 0-2000 ppm, 4-20 mA |
CR3950R417A | R417A detector, 0-2000 ppm, 4-20 mA |
CR3954R448 | R448 detector, 0-2000 ppm, 4-20 mA |
ACCESSORIES for SMART3G-C3 gas detectors | |
STS/CSW+ | Calibration software for SMART3G, SMART3NC, and SMART3R detectors consists of a USB key, a USB/RS485 converter, and an STS/IDI card. The software runs on Windows XP, Windows 7, and Windows 10. The calibration software allows you to modify the alarm thresholds and the measuring range and adjust the Zero, Span, and 4-20 mA values via a user-friendly menu, either in situ or in the laboratory. |
STS/IDI | Plug-in RCR485 interface to make SMART3G series gas detectors communicate in Modbus protocol with MULTISCAN++S1 & S2, MULTISCAN 8+, and STPL4+D control panels. |
STS/CKD+ | Enhanced calibration keypad with 7-digit display and SD-CARD slot. It can be connected to all SMART detectors to adjust the Zero, Span and 4-20 mA values. Via the SD-CARD, it is also possible to update the detector’s firmware (a feature not enabled on old SMART3G and NC detector) |
STS/CKD-OLED | Enhanced calibration keypad with OLED display and SD-CARD slot. It can be connected to all SMART detectors to adjust the Zero, Span and 4-20 mA values. This version offers enhanced features like: – visualisation of the instantaneous concentration in graphic format; – possibility to monitor the detector trend and download the data stored in the SD-CARD – detector’s firmware update via SD-CARD (feature not enabled on old SMART3G and NC detector) |
STS1REL | 1-Relay card for SMART3G. Relay at 12÷24V |
STS3REL | 3-Relay card for SMART3G. Relay at 12÷24V |
STGD/AD2 | Adapter for CR2096 & CR2097__ sensor heads to upgrade the protection from G to GD |
STGD/AD3 | Adapter for all sensor heads (exception made for CR2096 & CR2097__) to upgrade the protection from G to GD |