Crowcon Sensitron SMART 3G-C3 Gas Detector

Code: CR2096ME
  • Flammable, toxic & refrigerant gas detection
  • Aluminium housing
  • Approvals: EMC, ATEX, IECEx

In StockMake An Enquiry

The Sensitron SMART3G-C3 gas detector is designed to meet industrial requirements. Its enclosure is explosion-proof and can be installed in ATEX Zone 2 and, when equipped with a dust adapter, Zone 22.

The sensing element is placed in the stainless steel head with a 40 mm diameter.

The infrared sensors employed for flammable and refrigerant gas detection are poison-free, have high accuracy, and have a long lifetime.

The gas detector has a 12-24 Vdc power supply and a standard 4-20 mA 3-wire output. Optionally, the SMART3G-C3 can be equipped with serial RS485 communication and a 1 or 3 relay board.

The enclosure measures 106 x 160 x 62 mm and has an M20 cable gland on the upper side.

Order Information

  SMART3G-C3 – FLAMMABLE GAS (Catalytic sensor)
CR2096ME METHANE detector, 4-20 mA, 0-100% LFL
CR2096GP LPG detector, 4-20 mA, 0-100% LFL
CR2096BU BUTANE detector, 4-20 mA, 0-100% LFL
CR2096PR PROPANE detector, 4-20 mA, 0-100% LFL
CR2096VB PETROL VAPOURS detector, 4-20 mA, 0-100% LFL
CR2096H2 HYRDOGEN detector 4-20mA, 0-100% LFL
SMART3G-C3 – FLAMMABLE GAS (Infrared sensor)
CR2623ME METHANE detector, 4-20 mA, 0-100% LFL
CR2653BU BUTANE detector, 4-20 mA, 0-100% LFL
CR2653PR PROPANE detector, 4-20 mA, 0-100% LFL
CR2653GP LPG detector, 4-20 mA, 0-100% LFL
CR4432R454B R454B detector, 4-20 mA, 0-100% LFL
CR3424R32 R32 DIFLUOROMETHANE detector, 4-20 mA, 0-100% LFL
CR3428R1234YF R1234yf detector, 4-20 mA, 0-100% LFL
CR3432R1234ZE R1234ze detector, 4-20 mA, 0-100% LFL
SMART3G-C3 – TOXIC GASES (Electrochemical cell)
CR2640O2 OXYGEN (O2) detector, 0-25% Vol., 4-20 mA
CR2130CO CARBON MONOXIDE (CO) detector, 0-500 ppm, 4-20 mA
CR2130EL ETHYLENE (C2H4) detector, 0-200ppm
CR3224AM AMMONIA (NH3) detector, 0-100 ppm, 4-20 mA
CR2132AM AMMONIA (NH3) detector, 0-200 ppm, 4-20 mA
CR2134AM AMMONIA (NH3) detector, 0-1000 ppm, 4-20 mA
CR3228AM AMMONIA (NH3) detector, 0-5000 ppm, 4-20 mA
CR2136HS HYDROGEN SULPHIDE (H2S) detector, 0-50 ppm, 4-20 mA
CR2144NO NITRIC OXIDE (NO), 0-100 ppm, 4-20 mA
CR3592H2 HYDROGEN (H2) detector, 0-2000 ppm, 4-20 mA
CR4546H2 HYDROGEN (H2) detector, 0-3000 ppm, 4-20 mA
SMART3G-C3 – CO2 (Infrared sensor)
CR2649CO2 CARBON DIOXIDE (CO2) detector, 0-2% Vol., 4-20 mA
CR2650CO2 CARBON DIOXIDE (CO2) detector, 0-5% Vol., 4-20 mA
CR2443CO2 CARBON DIOXIDE (CO2) detector, 0-30% Vol., 4-20 mA
CR2444CO2 CARBON DIOXIDE (CO2) detector, 0-5000ppm, 4-20 mA
CR2629CO2 CARBON DIOXIDE (CO2) detector, 0-100% Vol., 4-20 mA
SMART3G-C3 – VOC detectors (PID sensors)
CR3540IL VOC detector, 0-20ppm, 4-20mA (Isobutylene)
CR3544IL VOC detector, 0-200ppm, 4-20mA (Isobutylene)
CR5121IL VOC detector, 0-2000ppm, 4-20mA (Isobutylene)
SMART3G-C3 – SF6 and REFRIGERANT GASES (Infrared sensor)
CR3942R32 R32 detector, 0-2000 ppm, 4-20 mA
CR3595R134A R134a detector, 0-2000 ppm, 4-20 mA
CR3598SF6 SF6 detector, 0-2000 ppm, 4-20 mA
CR3020R125 R125 detector, 0-2000 ppm, 4-20 mA
CR3021R1234YF R1234yf detector, 0-2000 ppm, 4-20 mA
CR3025R1234ZE R1234ze detector, 0-2000 ppm, 4-20 mA
CR3022R404A R404A detector, 0-2000 ppm, 4-20 mA
CR3023R407A R407A detector, 0-2000 ppm, 4-20 mA
CR3918R407F R407F detector, 0-2000 ppm, 4-20 mA
CR3921R449A R449 detector, 0-2000 ppm, 4-20 mA
CR3024R507A R507A detector, 0-2000 ppm, 4-20 mA
CR3016R410A R410A detector, 0-2000 ppm, 4-20 mA
CR3950R417A R417A detector, 0-2000 ppm, 4-20 mA
CR3954R448 R448 detector, 0-2000 ppm, 4-20 mA
ACCESSORIES for SMART3G-C3 gas detectors
STS/CSW+ Calibration software for SMART3G, SMART3NC, and SMART3R detectors consists of a USB key, a USB/RS485 converter, and an STS/IDI card. The software runs on Windows XP, Windows 7, and Windows 10. The calibration software allows you to modify the alarm thresholds and the measuring range and adjust the Zero, Span, and 4-20 mA values via a user-friendly menu, either in situ or in the laboratory.
STS/IDI Plug-in RCR485 interface to make SMART3G series gas detectors communicate in Modbus protocol with MULTISCAN++S1 & S2, MULTISCAN 8+, and STPL4+D control panels.
STS/CKD+ Enhanced calibration keypad with 7-digit display and SD-CARD slot. It can be connected to all SMART detectors to adjust the Zero, Span and 4-20 mA values. Via the SD-CARD, it is also possible to update the detector’s firmware (a feature not enabled on old SMART3G and NC detector)
STS/CKD-OLED Enhanced calibration keypad with OLED display and SD-CARD slot. It can be connected to all SMART detectors to adjust the Zero, Span and 4-20 mA values. This version offers enhanced features like: – visualisation of the instantaneous concentration in graphic format; – possibility to monitor the detector trend and download the data stored in the SD-CARD – detector’s firmware update via SD-CARD (feature not enabled on old SMART3G and NC detector)
STS1REL 1-Relay card for SMART3G. Relay at 12÷24V
STS3REL 3-Relay card for SMART3G. Relay at 12÷24V
STGD/AD2 Adapter for CR2096 & CR2097__ sensor heads to upgrade the protection from G to GD
STGD/AD3 Adapter for all sensor heads (exception made for CR2096 & CR2097__) to upgrade the protection from G to GD

Enquire About This Product

Title Size
SMART 3G-C3 Datasheet 1,012 KB

Additional information

Weight 0.190 kg

Specifications

Sensor
Application Industrial area, ATEX Zone 2 e Zone 22 (when equipped with dust adapter, optional)
Sensing element Infrared
Predicted sensor lifetime >5 years
Gas detected Flammable, refrigerant and CO2
Full scale 0 – 100% LFL flammable gas
0 – 2000 ppm refrigerant gas
0-2%Vol; 0-5%Vol; 0-30%Vol; 0-100%Vol CO2
Electrical data
Power supply 12-24 Vdc
Output Analogue 4-20 mA output; 1 or 3 relay board (optional); serial RS485 output (optional)
Maximum dissipated power 5.4 W
Relays contact ratings 1.0 A at 24 Vdc (optional board)
Optical indications
Acoustic indications
Hall effect sensor
Environmental conditions
Storage temperature -40 / +85°C
Operating temperature -40 / +60°C
Operating humidity 0 / 90% RH
External case
Material Enclosure: Aluminium
Sensor head: stainless steel
Protection mode Ex e: Increased safety protection mode
Ex nC: Enclosed equipment protection mode
Ex d : Explosion proof enclosure
Ex t : Equipment dust ignition protection by enclosure (when equipped with dust adapter, optional)
Dimensions 106 x 160 x 62 mm
Weight 1023 g
Cable entries 1 x M20
IP grade IP55 (certification pending)
Compliance
EMC EN 61000-6-3:2007 + A1:2011; EN 50270:2015
ATEX (certification pending) ATEX directive 2014/34/EU
EN IEC 60079-0:2018
EN 60079-1:2014
EN 60079-7:2015
EN 60079-15:2010
EN 60079-31:2014
SIL EN 61508:2010 Parts 1, 2, 3, 4, 5, 6, 7
EN50402:2017

Enquire About This Product