Crowcon Sensitron SMART 3G-C2-LD Infrared Gas Detector

Code: S2624ME-LD
  • Flammable, refrigerant & CO2
  • Designed for Industrial areas
  • Approval ATEX Zone 1 & Zone 21

In StockMake An Enquiry

The SMART3G-C2-LD is equipped with an infrared sensor and is designed to meet industrial requirements. The enclosure is explosion-proof and can be installed in ATEX Zone 1. It can be used in Zone 21 when fitted with a dust adapter.

The sensing element is placed in the stainless steel head with a 48 mm diameter.

The infrared sensors employed for flammable and refrigerant gas detection are poison-free, with high accuracy and a long lifetime.

The gas detector has a 12-24 Vdc power supply, a standard 4-20 mA 3-wires output, and three relays. Optionally, the SMART3G-C2-LD can be equipped with serial RS485 communication.

The aluminium enclosure has dimensions 145 x 187 x 108 mm. The enclosure has three cable entries that are 3/4” NPT threaded. The multi-colour LED light ring assures an immediate visual indication of the detector status.

The SMART3G-C2-LD is SIL2 hardware and SIL3 software with a redundant system; the hardware is SIL3.

Order Information

SMART3G-C2-LD – FLAMMABLE GAS (Infrared sensor)
S2624ME-LD METHANE detector, 4-20 mA, 0-100% LFL
S2654BU-LD BUTANE detector, 4-20 mA, 0-100% LFL
S2654PR-LD PROPANE detector, 4-20 mA, 0-100% LFL
S2654GP-LD LPG detector, 4-20 mA, 0-100% LFL
S2654AT-LD ACETONE detector, 4-20 mA, 0-100% LFL
S2654BN-LD BUTADIENE detector, 4-20 mA, 0-100% LFL
S2654CE-LD CYCLO HEXANE detector, 4-20 mA, 0-100% LFL
S2654DT-LD DIMETHYL ETHER detector, 4-20 mA, 0-100% LFL
S2654EN-LD ETHANE detector, 4-20 mA, 0-100% LFL
S2654AE-LD ETHYL ACETATE detector, 4-20 mA, 0-100% LFL
S2654ET-LD ETHYL ALCOHOL detector, 4-20 mA, 0-100% LFL
S2654EP-LD HEPTANE detector, 4-20 mA, 0-100% LFL
S2654ES-LD HEXANE detector, 4-20 mA, 0-100% LFL
S2654IB-LD ISO BUTANE detector, 4-20 mA, 0-100% LFL
S2654IL-LD ISOBUTYLENE detector, 4-20 mA, 0-100% LFL
S2654IP-LD ISO PROPYL ALCOHOL detector, 4-20 mA, 0-100% LFL
S2654PE-LD PENTANE detector, 4-20 mA, 0-100% LFL
S2654PP-LD PROPYLENE detector, 4-20 mA, 0-100% LFL
S2654DE-LD R152a DIFLUOROETHANE detector, 4-20 mA, 0-100% LFL
S4433R454B-LD R454B detector, 4-20 mA, 0-100% LFL
S4827R454C-LD R454C detector, 4-20mA, 0-100% LFL
S3425R32-LD R32 DIFLUOROMETHANE detector, 4-20 mA, 0-100% LFL
S3429R1234YF-LD R1234yf detector, 4-20 mA, 0-100% LFL
S3433R1234ZE-LD R1234ze detector, 4-20 mA, 0-100% LFL
SMART3G-C2-LD – CO2 (Infrared sensor)
S3898CO2-LD CARBON DIOXIDE (CO2) detector, 0-5000ppm, 4-20 mA
S2651CO2-LD CARBON DIOXIDE (CO2) detector, 0-2% Vol., 4-20 mA
S2652CO2-LD CARBON DIOXIDE (CO2) detector, 0-5% Vol., 4-20 mA
S2445CO2-LD CARBON DIOXIDE (CO2) detector, 0-30% Vol., 4-20 mA
S2630CO2-LD CARBON DIOXIDE (CO2) detector, 0-100% Vol., 4-20 mA
SMART3G-C2-LD – SF6 and REFRIGERANT GASES (Infrared sensor)
S3944R32-LD R32 detector, 0-2000 ppm, 4-20 mA
S3596R134A-LD R134a detector, 0-2000 ppm, 4-20 mA
S3599SF6-LD SF6 detector, 0-2000 ppm, 4-20 mA
S3656R125-LD R125 detector, 0-2000 ppm, 4-20 mA
S3657R1234YF-LD R1234yf detector, 0-2000 ppm, 4-20 mA
S3948R1234ZE-LD R1234ze detector, 0-2000 ppm, 4-20 mA
S3658R404A-LD R404A detector, 0-2000 ppm, 4-20 mA
S3659R407A-LD R407A detector, 0-2000 ppm, 4-20 mA
S3920R407F-LD R407F detector, 0-2000 ppm, 4-20 mA
S3923R449A-LD R449A detector, 0-2000 ppm, 4-20 mA
S3660R507A-LD R507A detector, 0-2000 ppm, 4-20 mA
S3017R410A-LD R410A detector, 0-2000 ppm, 4-20 mA
S3952R417A-LD R417A detector, 0-2000 ppm, 4-20 mA
S3956R448-LD R448 detector, 0-2000 ppm, 4-20 mA
ACCESSORIES
STS/CSW+ Calibration software for SMART3G, SMART3NC & SMART3R detectors consisting of a USB key, a USB/RS485 converter and the STS/IDI card. The software runs on Windows XP, Windows 7, and Windows 10. The calibration software allows the modification of the alarm thresholds and the measuring range and allows adjusting the Zero, Span and 4-20 mA values via a user-friendly menu, either in situ or in the laboratory.
STS/IDI Plug-in interface for RS485 serial communication suitable for SMART3G
STS/CKD+ Enhanced calibration keypad with 7-digit display. It can be connected to SENSITRON’S SMART detectors to adjust the Zero, Span and 4-20 mA values.
STS/CKD-OLED Enhanced calibration keypad with OLED display. It can be connected to all SENSITRON’S SMART detectors to adjust the Zero, Span and 4-20 mA values. This version offers the visualization of the instantaneous concentration in graphic format.
STGD/AD3 Adapter for all sensor heads (exception made for S2096__ & S2097__) to upgrade the protection from G to GD
RE21-PNA1KONK ATEX cable gland for non-armoured cables

Enquire About This Product

Title Size
SMART 3G-C2-LD Infrared Datasheet 2 MB

Additional information

Weight 0.190 kg

Specifications

Sensor
Application Industrial area, ATEX Zone 1 and Zone 21 (when equipped with dust adapter, optional)
Sensing element Infrared
Predicted sensor lifetime >5 years
Gas detected Flammable, refrigerant and CO2
Full scale 0 – 100% LFL flammable gas
0 – 2000 ppm refrigerant gas
0-2%Vol; 0-5%Vol; 0-30%Vol; 0-100%Vol CO2
Electrical data
Power supply 12-24 Vdc
Output Analogue 4-20 mA output; 3 relay board; serial RS485 output (optional)
Maximum dissipated power 5.4 W
Relays contact ratings 1.0 A at 24 Vdc
Optical indications Multi-colour LED light ring
Acoustic indications
Environmental conditions
Storage temperature -40 / +85°C
Operating temperature -40 / +60°C *
Operating humidity 20 / 90% RH @40°C *
Operating pressure 80 / 120 kPa *
Air velocity 6 m/s *
Time of response t90 < 60 s ; t50 < 20 s *
External case
Material Enclosure: aluminium pressure die-casting with epoxy paint chromating and chemically resistant
Sensor head: stainless steel
Protection mode Ex d : Explosion proof enclosure
Ex t : Equipment dust ignition protection by enclosure (when equipped with dust adapter, optional)
Dimensions 145 x 187 x 108 mm
Weight 1900 g
Cable entries 3 x 3/4” NPT
IP grade IP65
Compliance
EMC EN 61000-6-3:2007 + A1:2011; EN 50270:2015
ATEX ATEX directive 2014/34/UE
EN IEC 60079-0:2018
EN 60079-1:2014
EN 60079-31:2014
EN 60079-29-1:2016
IECEx IEC 60079-0:2011
IEC 60079-1:2014
IEC 60079-31:2013
SIL EN 61508:2010 Parts 1, 2, 3, 4, 5, 6, 7
EN50402:2017

Enquire About This Product