The Multiscan++S2 is a SIL2-certified, advanced multifunction gas detection control panel designed to meet the need for highly flexible systems. The system can manage and monitor up to 256 gas detectors and has a range of self-testing facilities to detect and localise possible failures.
Self-testing
The system’s powerful microprocessor allows a wide range of self-testing facilities to detect and localise possible failures.
Event log
The event log is fully viewable from the unit’s display and can be downloaded to a PC.
Cross-industry suitability
The Multiscan++S2 is a versatile system ideal for use in a wide range of applications and industries, including refineries, pharmaceutical and petrochemical plants, and the food and beverage industry.
Order Information
MULTISCAN++S2 | |
CRMTS/S2-256B | MULTISCAN++S2 gas control panel. 2 x RS485 type closed loops. 256 Analog 4-20 mA gas detectors connected through remote 8-input modules or addressable gas detectors daisy chained to the RS485 control panel’s loops and 8 x 4-20 mA inputs onboard the panel. 8 relay outputs and up to 512 O/C or relay outputs via remote modules. The panel has 1 parallel printer port and 1 RS232 serial port for PC connection. Housed in IP65 rated ABS box |
CRMTS/S2-256 | Rack version of CRTMTS/S2-256BThe panel is housed in a 19” 6 U rack (a 24 Vdc power supply is required). |
CRMTS/S2-128B | MULTISCAN++S2 gas control panel. 2 x RS485 type closed loops. 128 Analog 4-20 mA gas detectors connected through remote 8-input modules or addressable gas detectors daisy chained to the RS485 control panel’s loops and 8 x 4-20 mA inputs onboard the panel. 8 relay outputs and up to 256 O/C or relay outputs via remote modules. The panel has 1 parallel printer port and 1 RS232 serial port for PC connection. Housed in IP65 rated ABS box |
CRMTS/S2-128 | Rack version of CRTMTS/S2-128BThe panel comes housed in a 19” 6 U rack (24 Vdc power supply is required). |
CRMTS/S2-64B | MULTISCAN++S2 gas control panel. 2 x RS485 type closed loop. 64 Analog 4-20mA gas detectors connected through remote 8-input modules or addressable gas detectors daisy chained to the RS485 control panel’s loops and 8 x 4-20 mA inputs on board the panel. 8 relay outputs and up to 128 O/C or relay outputs via remote modules. The panel has 1 parallel printer port and 1 RS232 serial port for PC connection. Housed in IP65 rated ABS box |
CRMTS/S2-64 | Rack version of CRTMTS/S2-64BThe panel is housed in a 19” 6 U rack (a 24 VDC power supply is required). |
CRMTS/S2-32B | MULTISCAN++S2 gas control panel. 1 x RS485 type closed loop. 32 Analog 4-20mA gas detectors connected through remote 8-input modules or addressable gas detectors daisy chained to the RS485 control panel’s loops and 8 x 4-20 mA inputs onboard the panel. 8 relay outputs and up to 64 O/C or relay outputs via remote modules. The panel comes complete with 1 RS232 serial port for PC connection. Housed inIP65 rated ABS box |
CRMTS/S2-32 | Rack version of CRTMTS/S2-32BThe panel comes housed in a 19” 6 U rack (24 Vdc power supply is required). |
MULTISCAN++S2 ACCESSORIES | |
STG/IN8-S2 | 8 input remote module card for MULTISCAN++S2 control panel. |
STG/OUT16-S2 | 16 Open Collectors output remote module for MULTISCAN++S2 control panel. |
STG/8REL | Plug and play relay board to be connected to STG/OUT16-S2 to provide 8 relay outputs. |
STG/SER++ | Additional Serial board to implement serial lines in MULTISCAN++S2 (16,32,64) |
STG/TCPIP-C | TCP/IP interface for LAN connection |
AL11/276V5 | Metal Cabinet with enclosed 27.6 Vdc 5A Power Supply to house one of the above remote cards. |
STG/BOX | IP55 Plastic box to house one STG/IN8-S2 or STG/OUT16-S2 cards |
STG/32-85 | RS232/RS485 Interface for PC connection on RS485 line of MULTISCAN++ |