ABB Furse ESP 30E Surge Protector

Code: 7TCA085400R0104
  • Nominal voltage 30 V
  • Repeated protection in lightning-intense environments
  • Substantial earth stud to enable effective earthing

In StockMake An Enquiry

The ESP 30E is a combined Category D, C, and B tested protector (to BS EN 61643) suitable for twisted pair signalling applications requiring a lower in-line resistance, an increased current or a higher bandwidth than the ESP D Series. Also suitable for DC power applications less than 1.25 Amps.

For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ 3 to protect sensitive electronic equipment.

Features & Benefits

  • Very low let-through voltage (enhanced protection to IEC/BS EN 62305) between all lines – Full Mode protection.
  • Full Mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment.
  • Very low (1 Ω) in-line resistance allows protection of resistance-critical applications (e.g., alarm loops).
  • High (1.25 A) maximum running current.
  • Strong, flame retardant, ABS housing.
  • High bandwidth enables higher frequency (high traffic or bit rate) data communications.
  • Screen terminal enables easy connection of cable screen to earth.
  • Built-in DIN rail foot for simple clip-on mounting to top hat DIN rails.
  • Colour-coded terminals make installation checks quick and easy—grey for the dirty (line) end and green for clean.
  • Supplied ready for flat mounting on base or side.
  • Integral earthing plate for enhanced connection to earth via CME kit.
  • ESP 06E and ESP 15E have Network Rail Approval PA05/02047. NRS PADS reference 086/000201 (ESP 06E) and 086/000200 (ESP 15E).

Application

Use these units to protect resistance-sensitive, higher-frequency, or running-current systems, such as high-speed digital communications equipment or systems with long signal lines.

Installation

Connect in series with the data communication or signal line near where it enters or leaves the building or close to the protected equipment (e.g. within its control panel). Either way, it must be very close to the system’s earth star point. Install protectors either within an existing cabinet/cubicle or in a separate enclosure.

Specifications

  • Nominal voltage 30 V
  • Maximum working voltage Uc (RMS/DC) 25 V / 36.7 V
  • Current rating (signal) 1.25 A
  • In-line resistance (per line ±10%) 1.0 Ω
  • Bandwidth (-3 dB 50 Ω system) 45 MHz
  • Temperature range -40 to +80 °C
  • Connection type Screw terminal – maximum torque 0.5 Nm
  • Conductor size (stranded) 2.5 mm2
  • Earth connection M6 stud
  • Case material FR Polymer UL-94 V-0
  • Weight: Unit 0.08 kg
  • CN8: 8536308000

Enquire About This Product

Title Size
ESP 30E Datasheet 1 MB

Additional information

Weight 0.09 kg