The Detcon IR-700-CO2 by Teledyne is a non-intrusive “Smart” sensor designed to detect and monitor carbon dioxide gas in the air using miniature non-dispersive Infrared Optical (NDIR) sensor technology. Available in a low and a high range version, the ranges of detection (by volume) are 0-0.3%, 0-1%, 0-3%, 0-5% (low range version) and 0-10%, 0-25%, 0-50%, and 0-100% (high range version).

The plug-in, field-replaceable detector provides a selective response to CO2 and features oversized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual-layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes.

A primary feature of the Model IR-700-CO2 is embedded intuitive software that simplifies the operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model IR700-CO2 is equipped with standard analogue 4-20mA and Modbus™ RS-485 outputs. Additional integration options include a Remote Alarm Module (RAM) & HART. Detcon’s carbon dioxide gas sensor has an infinite shelf life and a 5-year warranty.

Suitable for Chemicals, Pesticides, Agriculture & Horticulture, Food & Beverage Bottling Plants, Sewer Entry, Waste Water Treatment Plants, Coal Gasification, Pulp & Paper Mills and Enhanced Oil Recovery.

Features

Failsafe User-Friendly Interface

  • LED Display (With Antiglare Cover)
  • Full-Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics

Environmentally Bulletproof

  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof
  • Vibration-Proof

Modular and Serviceable

  • Modular Design
  • Plug and Play Components
  • Quick Thread Release (For Sensor Replacement)
  • Integral Calibration Port

Order Information

700 Series IR CO2 Gas Detection Sensor Assemblies 0-5% range
967-405520-005 IR-700-CO2 Infrared Gas Sensor Assembly no condulet
967-401520-005 IR-700-CO2 Infrared Gas Sensor Assembly alum. condulet
967-404520-005 IR-700-CO2 Infrared Gas Sensor Assembly 316SS condulet
9H7-401520-005 IR-700-CO2 Infrared Gas Sensor w/Hart bridge Assembly alum. condulet
9H7-404520-005 IR-700-CO2 Infrared Gas Sensor w/Hart bridge Assembly 316SS. condulet
9R7-401520-005 IR-700-CO2 Infrared Gas Sensor w/RAM Assembly alum. condulet
9R7-404520-005 IR-700-CO2 Infrared Gas Sensor w/RAM Assembly 316SS condulet
9K7-401520-005 IR-700-CO2 Infrared Gas Sensor w/Hart-RAM Assembly alum. condulet
9K7-404520-005 IR-700-CO2 Infrared Gas Sensor w/Hart-RAM Assembly 316SS condulet
700 Series IR CO2 Gas Detection Sensor Assemblies 10-100% range
967-425520-100 IR-700-CO2 Infrared Gas Sensor Assembly no condulet
967-421520-100 IR-700-CO2 Infrared Gas Sensor Assembly alum. condulet
967-424520-100 IR-700-CO2 Infrared Gas Sensor Assembly 316SS condulet
9H7-421520-100 IR-700-CO2 Infrared Gas Sensor w/Hart bridge Assembly alum. condulet
9H7-424520-100 IR-700-CO2 Infrared Gas Sensor w/Hart bridge Assembly 316SS. condulet
9R7-421520-100 IR-700-CO2 Infrared Gas Sensor w/RAM Assembly alum. condulet
9R7-424520-100 IR-700-CO2 Infrared Gas Sensor w/RAM Assembly 316SS condulet
9K7-421520-100 IR-700-CO2 Infrared Gas Sensor w/Hart-RAM Assembly alum. condulet
9K7-424520-100 IR-700-CO2 Infrared Gas Sensor w/Hart-RAM Assembly 316SS condulet
IR-700-CO2 Spare Sensors
370-365878-700 CO2, Carbon dioxide 0-5% Vol. Plug-in Sensor for IR-700
370-287724-700 CO2, Carbon dioxide 10-100% Vol. Plug-in Sensor for IR-700
IR-700-CO2 Spares
S927-400000-xxx IR-700-CO2 Infrared Carbon Dioxide (ITM) Low Range (0-5%) – “xxx” Range – “_” Certification.
S927-420000-xxx IR-700-CO2 Infrared Carbon Dioxide (ITM) High Range (10-100%) – “xxx” Range – “_” Certification.
602-004216-000 Bottom housing assembly for FP/TP/IR – includes flame arrestor
Model Series 700 Integration Modules in Enclosures
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2
975-70000A-00A Remote Control / Alarm Relay Module in Aluminium Enclosure
975-70000A-00S Remote Control / Alarm Relay Module in 316SS Enclosure
975-70000H-00A Remote Control / Alarm Relay Module with Hart in Aluminium Enclosure
975-70000H-00S Remote Control / Alarm Relay Module with Hart in 316SS Enclosure
975-70005H-00A Hart Integration Module in Aluminium Enclosure
975-70005H-00S Hart Integration Module in 316SS Enclosure
Universal Spare Parts
613-120000-700 Sensor splash guard with integral cal-port
327-000000-000 Magnetic programming tool
975-000020-893 Sensor duct mount kit – 700 Series
500-003087-100 Transient Protection Module (standard terminal board)
500-005242-300 Hart Bridge Module
927-70000A-000 RAM Module
927-70000H-000 Hart/RAM Module
500-005134-100 Ram Terminal board
943-004221-000 Sensor Mounting Plate for 2″ pipe
943-004223-000 Sensor Mounting Plate with Sunshade for 2-3″ pipe
Accessories
943-000000-000 Calibration Sleeve/Wind Guard for use with the splash guard
960-202200-000 Condensation prevention packet (for J-Box replace annually)
437-500000-000 Stainless steel tag
943-004223-000 2″ pipe mount with sun shade
943-004221-000 Sensor Mounting Plate for 2″ pipe
943-002273-000 Harsh location dust guard (fits 1.5 x 18 thread) Fits 700’s, FP 4,5,600’s, DM series 5,600’s, DM-100’s,
033-003238-000 Harsh location dust guard replacement filter for 1.5 x 18 thread (Sold in a pack of qty 20 – order as 20ea)
943-002274-000 Hazardous location dust guard 7/8 fits TP-4, 5, 600 series sensors.
943-003236-000 Harsh location dust guard replacement filter for (fits 1.5 x 18 thread) (Sold in a pack of qty 20)
943-003436-000 Harsh location water guard, fits all series with standard splash guard.
897-850000-010 Standard aluminium junction box with solid lid
897-850901-010 Standard aluminium junction box with lens cover
897-850000-316 Stainless steel junction box with solid cover
897-850901-316 Stainless steel junction box with lens cover
943-121747-SS5 Stainless steel flow through adapter, Fits 700’s, FP 4,5,600’s, DM series 5,600’s, DM-100’s

Enquire About This Product

Title Size
IR-700-CO2 Brochure 178 KB
IR-700 Manual 4 MB

Additional information

Weight 0.09 kg

Specifications

System Specifications
Sensor Type Continuous diffusion/adsorption
Non-dispersive Infrared Optical (NDIR) – CO2
Sub-miniature plug-in field replaceable
Sensor Life 5 years typical
Measurement Range (% by volume) 0-0.3, 0-0.5, 0-1, 0-3, 0-5 (low range version)
0-10, 0-15, 0-20, 0-25, 0-50, 0-100 (high range version)
Accuracy/Repeatability ±5% of range
Response Time T50 < 15 seconds, T90 < 40 seconds
Outputs Linear 4-20 mA DC
RS-485 MODBUS-RTU
Electrical Classification Explosion proof
cCSAus
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C)
Class I, Zone 1, Group IIB+H2
ATEX
II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C)
Ingress Protection NEMA 4X, IP66
Safety Approvals cCSAus
ATEX
CE Marking
Warranty Plug-in detector – 5-year pro-rated
Transmitter – 2 Years
Environmental Specifications
Operating Temperature Range -40°F to +167°F; -40°C to +75°C
Storage Temperature Range -40°F to +167°F; -40°C to +75°C
Operating Humidity Range 0-100% RH non-condensing
Mechanical Specifications
Dimensions 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5”; 140mm centre to centre
Weight 2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input 11-30 VDC
Power Consumption Normal operation = 68mA (<1.7 watt)
Maximum = 85mA (2 watts)
Inrush Current 0.67A @ 24V
RFI/EMI Protection Complies with EN50270
Analog Output Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA All Fault Diagnostics
2mA In-Calibration
4-20mA 0-100% full-scale
22mA Over-range condition
Serial RS-485 Output RS-485 Modbus™ RTU
Baud Rate 9600 BPS (9600, N,8,1 Half Duplex)
Status Indicators 4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting
Faults Monitored Loop, Input Voltage, Zero, Sensor, Processor, Memory, Calibration
Cable Requirements Power/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair shielded cable specifically for use with
RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity

Enquire About This Product