Carbolite HVTT 1200C and HVTT 1500C Vacuum Tube Furnaces. A total of five models make up the range. 10-5 mbar is achievable using a vacant tube. All are floor standing furnaces, forming a base from which bespoke customer designs can be developed in order to meet specific application requirements.
1200C models are heated by a integral wire wound work tube. The 1500C models use parallel installed Silicon Carbide elements. Supplied with Carbolite Gero 301 digital PID controller, with inbuilt process timer and one ramp rate.
High Vacuum Tube Furnace Models
HVTT 15/75/450 has a maximum temperature of 1500C and a continuous operating temperature of 1400C. The inbuilt tube is 75mm internal diameter and the heated length is 450mm. Maximum power is 5500 watts. Overall dimensions height 1565mm, width 1700mm and depth 600mm.
HVTT 15/50/450 has a maximum temperature of 1500C and a continuous operating temperature of 1400C. The inbuilt tube is 50mm internal diameter and the heated length is 450mm. Maximum power is 5500 watts. Overall dimensions height 1565mm, width 1700mm and depth 600mm.
HVTT 12/50/550 has a maximum temperature of 1200C and a continuous operating temperature of 1100C. The inbuilt tube is 50mm internal diameter and the heated length is 550mm. Maximum power is 2000 watts. Overall dimensions height 1450mm, width 1700mm and depth 600mm.
HVTT 12/60/700 has a maximum temperature of 1200C and a continuous operating temperature of 1100C. The inbuilt tube is 60mm internal diameter and the heated length is 700mm. Maximum power is 3000 watts. Overall dimensions height 1450mm, width 1700mm and depth 600mm.
HVTT 12/80/700 has a maximum temperature of 1200C and a continuous operating temperature of 1100C. The inbuilt tube is 80mm internal diameter and the heated length is 700mm. Maximum power is 3500 watts. Overall dimensions height 1450mm, width 1700mm and depth 600mm.
Common Features
- Worktube connects to the vacuum system via 90° stainless steel radiused connection
- Cooling water failure alarm
- Manually operated roughing / backing baffle valve
- Controls housed under the furnace to the right
- Removing the stainless flange allows entrance to work tube (right)
- Radiation shields both ends of work tube
- Vacuum connection left and vacuum housed left at base
- Manual bypass hot gas protection valve
- Oil-free scroll dry pump (XDS) removes danger of back filling with oil
- Turbo molecular pump achieves higher vacuum than conventional models
- Horizontal operation
- Pirani gauge low vacuum monitor
- Penning gauge high vacuum monitor
- Control system can be upgraded with RS232 communications, adding more pressure switches, & relay options to communicate with a control panel or building management system for alarm activation
Options
- Over temperature protection if furnace left for long periods
- Additional safety systems for use with flammable atmospheres
- 3 Zone control to enhance uniformity
- Vertical custom configuration
- Choice of gas back fill
- Automatic and semi-automatic vacuum systems
- 8 Segment or 20 Segment ramping controller with storage options