The Drager Parat 3100 is designed for 15 minutes of escape time. It is a half-mask that covers the nose and uses a two-point head harness. Supplied in a robust case with traction grip areas and a grey security tag at the top, the unit should be serviced or replaced if opened.
Small, compact, and easy to carry (170 x 110 x 90 mm, 360g), it wears with an integral belt clip. You can see the filter expiry date and condition through the transparent cover. Open the Parat 3100 case by pulling the yellow tag.
Fitted with an ABEK 15 gas filter that protects against organic and inorganic gases and vapours, approved to DIN 58647 part 7. Maintenance-free with a 4-year life; replacing the filter every four years can extend the life to twelve years.
Also available in a vacuum-sealed aluminium bag designed for tropical climates, the Parat 3160 models are part of the Parat 3000 range.
| Filter capacity according to DIN 58647-7 | ||||
| Type | Test Gas | Concentration in PPM | Breakthrough in PPM | Minimum breakthrough time minute |
| A | Cyclohexane (C6H12) | 2500 | 10 | 15 |
| B | Chlorine (Cl2) | 2500 | 0.5 | 15 |
| B | Hydrogen sulphide (H2S) | 2500 | 10 | 15 |
| B | Hydrogen cyanide (HCN) | 2500 | 10 | 15 |
| E | Sulphur dioxide (SO2) | 2500 | 5.0 | 15 |
| K | Ammonia (NH3) | 2500 | 25 | 15 |
| B | Hydrogen sulphide (H2S) | 10000 | 20 | 5 |
| Test conditions: 30 L/min, 70% relative humidity, 20°C.
To determine the gas filter’s breakthrough capacity, it is additionally tested with 10,000 ppm hydrogen sulphide. |
||||
Order Information
R57981 Parat 3100 Half mask with ABEK15 filter 3704476. Previously R56311
R62630 Parat 3160 Half mask with ABEK15 filter 3704477
Accessories for training units
R56353 Parat 3100 Housing Cover, blue (training device component)
Replacement filters and parts
R57983 ABEK15 Replacement Filter (5 pieces). Previously R56350
R56355 Parat 3000 Security Tag (50 pieces)
R56319 Parat 3000 TPE Sealing Strap
R28175 Parat 3000 Carrying Belt