TSI Mass Flow Meters

Code: 4040
  • 4 millisecond flow response
  • High accuracy ±2% of reading
  • Built-in temperature and pressure compensation

In StockMake An Enquiry

TSI mass flow meters are designed for Laboratory, Industry or Medical applications demanding high accuracy and a choice of data output options. The sensor uses proprietary platinum film to measure gas flow.

There are nine TSI mass flow meters, falling into two types; the high flow 4000 range, 0-300 L/min and the low flow 4100 series 0.01-20 L/min. All models are calibrated for air, additional calibrations for Oxygen and Nitrogen are available for both types.  Low flow models can have Nitrous Oxide calibrations.

Two outputs are included analogue 0-10 VDC flow only, zero and span adjustable via RS232 and digital RS232 output.

Accuracy is ±2% at full-scale flow rate reading. If a full scale is 300 L/min, then the uncertainty for all readings is ±6 L/min. One TSI flow meter covers the same range as three or more “percent of full scale” devices, with better accuracy at all points. The rapid four-millisecond response gives accuracy when the flow is variable. This fast response time is ideal for closed-loop control systems and integrated volume measurements. Pressure and temperature measurements are also fast. A low-pressure drop minimises flow circuit back pressure and its impact on the system under test.

Features

  • Turn-down ratios greater than 1000:1
  • High Accuracy- pressure ±1 kPa & temperature ±1°C at flow greater than 1 Std L/min
  • Digital and Analog outputs
  • Multi-gas, user-selectable
  • Fast 4 ms response flow changes
  • Little pressure loss
  • Measure flow rate, temperature, and pressure (display unit only) in one instrument
  • Calibration certificate is NIST-traceable and included with purchase

Models – Sector Suitability Detailed

40401 measures air, connection tube size 22mm ISO, Range L/min 0-300, medical, r&d and industry.
4040  measures air, O2, & N2 connection tube size 22mm ISO, Range L/min 0-300, medical, r&d and industry.
4043  measures air, O2, & N2 connection tube size 1/2″, Range L/min 0-200, industry.
4045  measures air, O2, & N2 connection tube size 3/4″, Range L/min 0-300, industry.
41401  measures air, connection tube size 1/4″, Range L/min 0.01-20, industry.
4140  measures air, O2, & N2 connection tube size 1/4″, Range L/min 0.01-20, medical, r&d and industry.
4143  measures air, O2, & N2 connection tube size 3/8″ Range L/min 0.01-20, medical, r&d and industry.
41403  measures air, O2, & N2O connection tube size 1/4″ Range L/min 0.01-20, medical.
41433  measures air, O2, N2 & N2O connection tube size 3/8″ Range L/min 0.01-20, medical.

Enquire About This Product

Title Size
4000 Mass Flowmeters 652 KB

Additional information

Weight 0.09 kg