Geotech G210 Lightweight Gas Leak Detector

Code: G210-01N
  • 4 gases measured in one analyser
  • Easy user calibration
  • Quick verification of gas quality

In StockMake An Enquiry

The G210 is specifically designed for highly accurate measurement and verification of the quality of piped N2O and O2 gases in hospitals.

Features

  • 0 – 100% N2O.
  • 0 – 100% O2.
  • 0 – 500 ppm CO (optional).
  • 0 – 2000 ppm CO2.
  • Data storage with site and ID input.
  • User alarms.

Benefits

  • Enter the specific site and IDs for monitoring points.
  • Identify contaminants CO and CO2.

Applications

  • Hospital piped gases.
  • Leak detection.

Brand

  • Geotech/QED Environmental Systems.

Order Information

Analysers:

G210-01N G210 (N2O 0-100%) (CO2 0-2000PPM)
G210-10B G210 (N2O 0-100%) (CO2 0-2000PPM) (O2 0-100%)
G210-10N G210 (N2O(0-100%) CO2 (0-2000PPM) (O2 0-100%)
G210-11B G210 (N2O 0-100%) (CO2 0-2000PPM) (O2 0-100% (CO 0-500PPM)
G210-11L GAS ONLY (N2O 0-100%) (O2 0-100%) (CO2 0-2000PPM)
G210-11N GAS ONLY (N2O 0-100%) (O2 0-100%) (CO2 0-2000PPM)
G210-11PKG GAS PKG (N2O 0-100%) (O2 0-100%) (CO2 0-2000PPM)

Accessories:

USBLEAD2 USB Lead
068296/S Spare Sample Filters (pack of 5)
G1.6 Sample Tube Kit
050227 Hard Carry Case
CDA7.6 Spare Calibration Gas (Various gas options available)
073024 Mains Charger including Worldwide Adaptors
G1.11 Soft Carry Case
G1.10 Soda Lime Filter Kit
G1.4 Analyser Data Manager Software
G1.1 Regulator and Tubing for Calibration Gas

 

    Enquire About This Product


    Title Size
    G210 Datasheet 2 MB

    Additional information

    Weight 0.09 kg

    Specifications

    POWER SUPPLY
    Battery type Li Ion
    Battery life 12 hours (10 hours with pump)
    Battery lifetime 600 cycles
    Battery charger 5Vdc external power supply and internal charging circuit
    Charge time 4 hours
    Alternative power 5Vdc power supply
    GAS RANGES
    Gases measured N2O – By custom dual wavelength infra-red cell
    CO2 – By custom dual wavelength infra-red cell
    O2 (optional) – By internal electrochemical cell
    CO (optional) – By internal electrochemical cell
    Oxygen cell lifetime Approximately 3 years in air
    CO cell lifetime Approximately 2 years in air
    Range N2O – 0-100%
    CO2 – 0-2000ppm
    O2 – 0-100%
    CO – 0-500ppm
    Typical accuracy* N2O – ± 1% of range after calibration
    CO2 – ± 3% of range after calibration
    O2 – ± 0.5% of range after calibration
    CO – ± 2ppm for 0-20ppm after calibration
    CO – ± 5% of range from 21- 500ppm after calibration
    Response time T90 CO2 – ≤ 20 seconds
    O2 – ≤ 60 seconds
    N20 – ≤ 20 seconds
    CO – ≤ 60 seconds
    *Typical accuracies All typical accuracies quoted are after calibration plus accuracy of calibration gas used.
    FACILITIES
    Visual and audible alarms User selectable N2O, CO, CO2 and O2 alarm levels
    Communications USB type B mini-connector, HID device class
    Data storage 1000 reading sets plus 270 events
    50 site IDs and 300 sample point
    PUMP
    Flow 100cc / min typically
    ENVIRONMENTAL CONDITIONS
    Operating temperature 0°C to +50°C
    Relative humidity 5% to 95% non condensing
    Barometric pressure 500 to 1500mb
    IP rating IP40
    PHYSICAL
    Weight 500 grams
    Size L 165mm, W 100mm, D 55mm
    Case material ABS / polypropylene with silicone rubber inserts
    Keys 17 resin capped silicone rubber keys
    Display Liquid crystal display, 128 x 64 pixel
    With RGB LED back-light
    Gas sample flters User replaceable PTFE water trap filter
    CERTIFICATION
    EN 50270 :2006 Electromagnetic compatibility- electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen
    EN61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use.

      Enquire About This Product