Crowcon’s BESafe offers fast, accurate detection of hydrogen (H2), carbon monoxide (CO), and methane (CH4). Its dual-channel capability enables simultaneous monitoring of two gases and allows flexible configuration to suit different applications.
Specifically developed for the demands of battery backup and energy storage systems, BESafe features remote smart sensors that simplify installation and require minimal maintenance throughout their lifecycle.
Dual Channel Gas Detector for Battery Energy Storage
Detecting hydrogen, carbon monoxide and methane released during thermal runaway, enabling fast, reliable safety response.
Dual Channel Gas Detection
Supports two gas sensors, allowing flexible configurations based on application needs. Sensors can be placed remotely to monitor hard-to-reach areas or where space is constrained.
High-Performance Swappable Smart Sensors
Easily swap out pre-calibrated sensor trays without manufacturer intervention, reducing downtime and maintenance costs. Supports remote, non-intrusive testing to verify performance without interrupting operations. The sensor life indicator monitors service life and signals end-of-life status.
Multiple Signal Output
Analogue and relay outputs integrate easily with existing control systems and support multi-level audio-visual alarms. Additionally, RS-485 communication with Modbus RTU enables remote monitoring and data transmission.
User-Friendly Interface
High-definition OLED display clearly shows gas readings and alarms in any lighting conditions. At the same time, simple button controls make setup and adjustments quick and intuitive.
Compact and Flexible Structural Design
Compact design fits into limited spaces such as energy storage cabinets. The IP65-rated housing ensures reliable performance in harsh environments.
On-Site, Built-In Alarm Functions
High-decibel audible alarm and bright status indicators instantly alert users to abnormal status and provide at-a-glance visibility of operational state. Additionally, relay output can trigger external alarms or ventilation fans.
Order Information
Spares:
C038011 Remote Cable Adapter Transmitter End
C038012 Remote Cable Adapter Sensor Module End
C038014 Front Enclosure
C038013 Display PCB
C038016 3 Way Terminal Block
C038017 4 Way Terminal Block
C038018 6 Way Terminal Block
C038019 Molex Connector Cable
C038020 Sensor Terminal Block Holder
Sensors:
C038A11 Sensor Module Methane CH4 Cat. 0-100% LEL
C038A12 Sensor Module Methane CH4 Cat. 0-25% LEL
C038A21 Sensor Module Hydrogen H2 Cat. 0-100% LEL
C038A22 Sensor Module Hydrogen H2 Cat. 0-25% LEL
C038A31 Sensor Module Carbon Monoxide CO EC 0-50 ppm
C038A32 Sensor Module Carbon Monoxide CO EC 0-100 ppm
C038A33 Sensor Module Carbon Monoxide CO EC 0-200 ppm
C038A34 Sensor Module Carbon Monoxide CO EC 0-500 ppm
C038A35 Sensor Module Carbon Monoxide CO EC 0-1000 ppm