- Test commercial catering gas appliances for UK CP42 certificates – meets CIS23 & BS8494
- Test commercial catering & workplace ventilation airflow, temp & RH
- Test domestic & commercial flueless gas appliances, space & water heaters
- Fast track UK CMDDA1 room CO investigations – up to 4 rooms simultaneously with optional KANE79 CO monitors
- Perform gas appliance integrity tests – tightness, let by & appliance sweep test*
- Measure heat pump differential flow & return temp with optional WPCP2 clamp probes
- Measure differential pressure for appliance pressures & draught
- Suitable for CMDDA1 or IGEM/GL/8 investigation, CCCN1 & COM-CAT*
- Meets EN50543 for ambient CO2 & CO
- Meets EN50379 for O2, CO & NO*
- * Sensor dependant – select CO & ambient CO2 to perform:
- Room CO & CO2 safety tests
- Appliance sweep tests
- Flueless gas appliance, space & water heater tests
Features
- Room migration timed test for CO & CO2 with ambient CO2 sensor
- Appliance timed sweep test for CO & CO2 with ambient CO2 sensor
- Tests Type C sealed appliances, Type B boiler open flue & Type A cooker, space & water heaters
- Data hold, log & print reports with user details to optional KANE-IRP3 printer
- Wireless transfer to KANE LIVE or 3rd party apps
- 10-year warranty when serviced & recertified by KANE
Measures
- CO2 0-20%
- CO2 0-9999ppm
- CO 0-2000ppm or 10000ppm H2 compensation
- NO 0-600ppm
- O2 0-21%
- Differential temperature -20 to +1350°C – with suitable probes
- Differential pressure -80 to +80mBar
- Airflow 1.1 – 20m/s with KANE-DTHA2
- Temperature -20 – +50°C with KANE-DTHA2
- RH 0.1 – 99% with KANE-DTHA2
- Room CO 0-999ppm with optional KANE79 CO monitor
Applications
- Boiler & Heat Pump flow & return temperatures
- Commercial premises IAQ, airflow & humidity
- Room CO tests – up to 4 simultaneously
Box Contents
- KANE-DTHA2 anemometer
- 20128 extender
- USB1 charger
- 14102/2 large carry bag
Order Information
- KANE-AQA1 1 Gas IAQ analyser with KaneLink, measures ambient CO2 0-9999ppm, supplied with SGAP sampling probe & USB1 charger
- KANE-AQA1M As KANE-AQA1 measures CO 0-10,000ppm with H2 compensation and over range protection
- KANE-AQA1H As KANE-AQA1 measures CO 0-100,000ppm / 10%
- KANE-AQA1O As KANE-AQA1 measures O2 0-21%
- KANE-AQA1N As KANE-AQA1 measures NO 0-600ppm
- KANE-AQA2 2 Gas IAQ analyser with KaneLink, measures ambient CO2 0-9999ppm, CO 0-10,000ppm with H2 compensation and over range protection, supplied with SGAP sampling probe & USB1 charger
- KANE-AQA2H As KANE-AQA2 measures ambient CO2 0-9999ppm, CO 0-100,000ppm / 10%
- KANE-AQA2O As KANE-AQA2 measures ambient CO2 0-9999ppm, O2 0-21%
- KANE-AQA2N As KANE-AQA2 measures ambient CO2 0-9999ppm, NO 0-600ppm
- KANE-AQA2OM As KANE-AQA2 measures O2 0-21%, CO 0-10,000ppm
- KANE-AQA2OH As KANE-AQA2 measures O2 0-21%, CO 0-100,000ppm / 10%
- KANE-AQA2ON As KANE-AQA2 measures O2 0-21%, NO 0-600ppm
- KANE-AQA2MN As KANE-AQA2 measures CO 0-10,000ppm, NO 0-600ppm
- KANE-AQA2HN As KANE-AQA2 measures CO 0-100,000ppm / 10%, NO 0-600ppm
- KANE-AQA3 3 Gas IAQ analyser with KaneLink, measures ambient CO2 0-9999ppm, CO 0-10,000ppm with H2 compensation, NO 0-600ppm and over range protection, supplied with SGAP sampling probe & USB1 charger
- KANE-AQA3H As KANE-AQA3 measures ambient CO2 0-9999ppm, CO 0-100,000ppm / 10% & NO 0-600ppm
- KANE-AQA3O As KANE-AQA3 measures O2 0-21%, CO 0-10,000ppm & NO 0-600ppm
- KANE-AQA3OH As KANE-AQA3 measures O2 0-21%, CO 0-100,000ppm / 10& & NO 0-600ppm
- KANE-AQA4 4 Gas IAQ analyser with KaneLink,measures ambient CO2 0-9999ppm, CO 0-10,000ppm with H2 compensation, NO 0-600ppm, O2 0-21% and over range protection, supplied with SGAP sampling probe & USB1 charger
- KANE-AQA4H As KANE-AQA4 measures ambient CO2 0-9999ppm, CO 0-100,000ppm / 10%, NO 0-600ppm, O2 0-21%